My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1238 S Cypress - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Cypress Ave
>
1238 S Cypress Ave
>
1238 S Cypress - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2025 8:01:25 AM
Creation date
5/30/2025 8:00:45 AM
Metadata
Fields
Template:
Plan
Permit Number
20177841
101112622
Full Address
1238 S Cypress Ave
Stamp
ID:
1
Creator:
Import Agent
Created:
5/30/2025 8:00 AM
Modified:
5/30/2025 7:59 AM
ID:
2
Creator:
Import Agent
Created:
5/30/2025 8:00 AM
Modified:
5/30/2025 7:59 AM
ID:
3
Creator:
Import Agent
Created:
5/30/2025 8:00 AM
Modified:
5/30/2025 7:59 AM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
(1) BRANCH OF (8) MICRO-INVERTERS <br />(1) BRANCH OF (7) MICRO-INVERTERS <br />1 <br />(15)HANWHA Q CELL QPEAK DUO BLK ML-G10 <br />400W MODULES WITH (15)ENPAHSE <br />IQ8PLUS-72-2-US(240V)(SI-1) <br />(N)JUNCTION <br />BOX <br />2 <br />ENPHASE Q CABLE <br />DC CONDUCTORS <br />AC CONDUCTORS <br />3 <br />(E)200A END FED <br />MAIN PANEL <br />UTILITY <br />GRID <br />(E <br />) <br />2 <br />0 <br />0 <br />A <br /> <br />M <br />A <br />I <br />N <br />BR <br />E <br />A <br />K <br />E <br />R <br />PV BREAKER AT THE <br />OPPOSITE END OF <br />BUSBAR <br />(N)30A 2P <br />PV BREAKER <br />EXISTING 120/240V 1PH 60HZ <br />METER#:SCE <br />222013-519809M <br />N <br />G <br />(E) GROUND <br />ELECTRODE <br />LOADS <br />(N)30A AC <br />DISCONNECT <br />AC DISCONNECT <br />NON FUSED 30A, <br />120/240V, 2P <br />10A <br />(N)ENPHASE IQ <br />COMBINER 4 <br />20A <br />20A <br />AC COMBINER BOX <br />X-IQ-AM1-240-4 120/240 <br />NEMA 3R INSTALL <br />(2)20A PV 2P BREAKERS <br />(ONLY FOR SOLAR, NO <br />LOADS TO BE ADDED) <br />(E)(20)HYUNDAI HIS-S260RG 260W MODULES WITH <br />(E)(20)ENPHASE M215-60-2LL-S22/23-IG(240V) <br />(E)JUNCTION <br />BOX <br />E E <br />ENPHASE Q CABLE <br />DC CONDUCTORS <br />AC CONDUCTORS <br />E <br />(E)30A AC <br />DISCONNECT <br />AC DISCONNECT <br />NON FUSED 60A, <br />120/240V, 2P <br />(E)LOAD COMBINER <br />20A <br />3 <br />INSTALL (2)30A PV 2P <br />BREAKERS <br />(ONLY FOR SOLAR, NO <br />LOADS TO BE ADDED) <br />EXISTING PV SYSTEM <br />(E)30A 2P <br />PV <br />BREAKER <br />(E)PV METER <br />M <br />PV PRODUCTION <br />METER 120/240V <br />E <br />E <br />MODULE SPECIFICATION <br />MODEL <br />HANWHA Q CELL <br />QPEAK DUO BLK <br />ML-G10 400W <br />MODULE POWER @ STC 400W <br />OPEN CIRCUIT VOLTAGE:Voc 45.30V <br />MAX POWER VOLTAGE:Vmp 37.13V <br />SHORT CIRCUIT CURRENT:Isc 11.14A <br />MAX POWER CURRENT:Imp 10.77A <br />ADDRESS:1238 CYPRESS AVENUE, <br />SANTA ANA, CA 92707 <br />33.732077, -117.866857 <br />APN:014-01-116 <br />CUSTOMER INFORMATION <br />NAME:VICTOR BALLINAS <br />DATE:10/4/2022 <br />SCALE:AS NOTED REV:A <br />AHJ:CA - CITY OF SANTA ANA <br />UTILITY:SCE <br />PRN NUMBER:MAS-64171 <br />DRAFTED BY: <br />M.SAILESH <br />QC'ED BY:H.RAJ <br />PAPER SIZE:17"X11" <br />SOLARPLEX LLC <br />Dba MARAVILLA CONSTRUCTION <br /> License#:1056065 <br /> 5902 FIRESTONE BLVD <br /> SOUTH GATE, CA 90280 <br /> TEL:(562) 806-6000 <br /> FAX:(562) 806-4006 <br />SINGLE LINE DIAGRAM <br />E-01 <br />1. CONDUCTORS EXPOSED TO SUNLIGHT <br />SHALL BE LISTED AS SUNLIGHT <br />RESISTANT PER CEC 310.10(D). <br />2. CONDUCTORS EXPOSED TO WET <br />LOCATIONS SHALL BE SUITABLE FOR <br />USE IN WET LOCATIONS PER CEC <br />310.10(C). <br />3. MAXIMUM DC/AC VOLTAGE DROP SHALL <br />BE NO MORE THAN 2%. <br />4. ALL CONDUCTORS SHALL BE IN <br />CONDUIT UNLESS OTHERWISE NOTED. <br />5. BREAKER/FUSE SIZES CONFORMS TO <br />CEC 240.6 CODE SECTION. <br />6. AC GROUNDING ELECTRODE <br />CONDUCTOR SIZED PER CEC 250.66. <br />7. AMBIENT TEMPERATURE CORRECTION <br />FACTOR IS BASED ON CEC 690.31(A). <br />8. AMBIENT TEMPERATURE ADJUSTMENT <br />FACTOR IS BASED ON CEC 310.15(B)(2). <br />9. MAX. SYSTEM VOLTAGE CORRECTION IS <br />PER CEC 690.7. <br />10. CONDUCTORS ARE SIZED PER WIRE <br />AMPACITY TABLE CEC 310.15(B)(16). <br />ELECTRICAL NOTESSINGLE LINE DIAGRAM: DC SYSTEM SIZE - 6000W, AC SYSTEM SIZE - 4350W, CEC AC RATING:5405W <br />AC WIRE SIZING CALCULATIONS BASED OF FOLLOWING EQUATIONS >> <br />· REQUIRED CONDUCTOR AMPACITY: INVERTER OUTPUT CURRENT X #OF <br />INVERTERS = MAX CURRENT PER 690.8(A)(3) X 125% = MAX CURRENT PER <br />690.8(B)(1) <br />· CORRECTED AMPACITY CALCULATIONS: AMPACITY X TEMPERATURE DERATE <br />FACTOR X CONDUIT FILL DERATE = DERATED CONDUCTOR AMPACITY PER <br />690.8(B)(2) <br />· DERATED CONDUCTOR AMPACITY CHECK: MAX CURRENT PER 690.8(A)(3) <br /><DERATED CONDUCTOR AMPACITY <br />AC WIRE CALCULATIONS:- MATERIAL:COPPER & TEMPERATURE RATING:90°C <br />TAG ID REQUIRED CONDUCTOR AMPACITY CORRECTED AMPACITY CALCULATION DERATED CONDUCTOR AMPACITY CHECK <br />1 1.21 X 8 = 9.68 X 1.25 = 12.10A 30 X 0.87 X 1 =26.10A 12.10A <26.10A <br />2 1.21 X 8 = 9.68 X 1.25 = 12.10A 40 X 0.87 X 0.8 =27.84A 12.10A <27.84A <br />3 1.21 X 15 = 18.15 X 1.25 = 22.69A 40 X 0.87 X 1 =34.80A 22.69A <34.80A <br />CONDUIT SCHEDULE <br />TAG ID CONDUIT SIZE CONDUCTOR NEUTRAL GROUND <br />1 NONE (2) 12AWG ENPHASE Q CABLE <br />PER BRANCH CIRCUIT NONE (1) 6AWG BARE COPPER <br />2 3/4"EMT (4) 10AWG THHN/THWN-2 NONE (1) 8AWG THHN/THWN-2 <br />3 3/4"EMT (2) 10AWG THHN/THWN-2 (1) 10AWG THHN/THWN-2 (1) 8AWG THHN/THWN-2 <br />NOTE: <br />MAIN PANEL RATING:200A, MAIN BREAKER RATING:200A <br />120% RULE: (200AX1.2)-200A=40A =>ALLOWABLE BACKFEED IS 40A <br />OCPD CALCULATIONS: <br />INVERTER OVERCURRENT PROTECTION= <br />INVERTER O/P I X CONTINUOUS LOAD(1.25)X #OF INVERTERS <br />=1.21x15x1.25=22.69 A =>PV BREAKER = 30A <br />ALLOWABLE BACKFEED 40A =>30A PV BREAKER <br />THE DESIGNED INTERCONNECTION MEETS THE 705.12(B)(2) REQUIREMENTS. <br />ELECTRICAL CALCULATION <br />MICRO INVERTER SPECIFICATIONS <br />MODEL <br />ENPAHSE <br />IQ8PLUS-72-2-US(240V)(SI- <br />1) <br />POWER RATING 290W <br />MAX OUTPUT CURRENT 1.21A <br />CEC WEIGHTED EFFICIENCY 97% <br />MAX NO OF MICRO <br />INVERTERS/BRANCH 13 <br />MAX DC VOLTAGE 60V <br />NOTE: <br />1. EACH MICRO INVERTER IS RAPID SHUTDOWN COMPLIANT. <br />1238 S Cypress - <br />2017784102/16/23
The URL can be used to link to this page
Your browser does not support the video tag.