(1) BRANCH OF (8) MICRO-INVERTERS <br />(1) BRANCH OF (7) MICRO-INVERTERS <br />1 <br />(N)(15)HANWHA Q CELL QPEAK DUO BLK ML-G10+ 400W <br />MODULES WITH <br />(15)ENPAHSE IQ8PLUS-72-2-US(240V)(SI-1) <br />(N)JUNCTION <br />BOX <br />2 <br />ENPHASE Q CABLE <br />DC CONDUCTORS <br />AC CONDUCTORS <br />3 <br />(N)30A AC <br />DISCONNECT <br />AC DISCONNECT <br />NON FUSED 30A, <br />120/240V, 2P <br />(N)ENPHASE IQ <br />COMBINER 4 <br />20A <br />20A <br />ENPHASE COMBINER BOX <br />X-IQ-AM1-240-4 120/240 <br />NEMA 3R INSTALL <br />(2)20A PV 2P BREAKERS <br />(ONLY FOR SOLAR, NO <br />LOADS TO BE ADDED) <br />(E)(20)HYUNDAI HIS-S260RG 260W MODULES WITH <br />(E)(20)ENPHASE M215-60-2LL-S22/23-IG(240V) <br />(E)JUNCTION <br />BOX <br />E E <br />ENPHASE Q CABLE <br />DC CONDUCTORS <br />AC CONDUCTORS <br />E <br />(E)30A AC <br />DISCONNECT <br />AC DISCONNECT <br />NON FUSED 60A, <br />120/240V, 2P <br />(E)LOAD COMBINER <br />30A <br />3 <br />INSTALL (1)30A PV 2P <br />BREAKERS <br />(ONLY FOR SOLAR, NO <br />LOADS TO BE ADDED) <br />EXISTING PV SYSTEM <br />(E)PV METER <br />M <br />PV PRODUCTION <br />METER 120/240V <br />E <br />E <br />4 <br />(N)30A <br />INSTALL (2)30A 2P <br />BREAKERS <br />(ONLY FOR SOLAR, NO <br />LOADS TO BE ADDED) <br />(N)100A LOAD CENTER <br />(E)30A <br />(E)200A END FED <br />MAIN PANEL <br />UTILITY <br />GRID <br />(E <br />) <br />2 <br />0 <br />0 <br />A <br /> <br />M <br />A <br />I <br />N <br />BR <br />E <br />A <br />K <br />E <br />R <br />(E) GROUND <br />ELECTRODE <br />60A SUB FEEDER <br />BREAKER <br />(N)100A SUB <br />PANEL <br />60A PV BREAKER <br />AT OPPOSITE END <br />OF THE BUS BAR <br />4 <br />EXISTING 120/240V 1PH 60HZ <br />METER#:SCE <br />222013-519809M <br />MODULE SPECIFICATION <br />MODEL <br />HANWHA Q CELL <br />QPEAK DUO BLK <br />ML-G10+ 400W <br />MODULE POWER @ STC 400W <br />OPEN CIRCUIT VOLTAGE:Voc 45.30V <br />MAX POWER VOLTAGE:Vmp 37.13V <br />SHORT CIRCUIT CURRENT:Isc 11.14A <br />MAX POWER CURRENT:Imp 10.77A <br />ADDRESS:1238 CYPRESS AVENUE, <br />SANTA ANA, CA 92707 <br />33.732077, -117.866857 <br />APN:014-01-116 <br />CUSTOMER INFORMATION <br />NAME:VICTOR BALLINAS <br />DATE:11/12/2022 <br />SCALE:AS NOTED REV:D <br />AHJ:CA - CITY OF SANTA ANA <br />UTILITY:SCE <br />PRN NUMBER:MAS-64171 <br />DRAFTED BY: <br />M.SAILESH <br />QC'ED BY:H.RAJ <br />PAPER SIZE:17"X11" <br />SOLARPLEX LLC <br />Dba MARAVILLA CONSTRUCTION <br /> License#:1056065 <br /> 5902 FIRESTONE BLVD <br /> SOUTH GATE, CA 90280 <br /> TEL:(562) 806-6000 <br /> FAX:(562) 806-4006 <br />SINGLE LINE DIAGRAM <br />E-01 <br />1. CONDUCTORS EXPOSED TO SUNLIGHT <br />SHALL BE LISTED AS SUNLIGHT <br />RESISTANT PER CEC 310.10(D). <br />2. CONDUCTORS EXPOSED TO WET <br />LOCATIONS SHALL BE SUITABLE FOR <br />USE IN WET LOCATIONS PER CEC <br />310.10(C). <br />3. MAXIMUM DC/AC VOLTAGE DROP SHALL <br />BE NO MORE THAN 2%. <br />4. ALL CONDUCTORS SHALL BE IN <br />CONDUIT UNLESS OTHERWISE NOTED. <br />5. BREAKER/FUSE SIZES CONFORMS TO <br />CEC 240.6 CODE SECTION. <br />6. AC GROUNDING ELECTRODE <br />CONDUCTOR SIZED PER CEC 250.66. <br />7. AMBIENT TEMPERATURE CORRECTION <br />FACTOR IS BASED ON CEC 690.31(A). <br />8. AMBIENT TEMPERATURE ADJUSTMENT <br />FACTOR IS BASED ON CEC 310.15(B)(2). <br />9. MAX. SYSTEM VOLTAGE CORRECTION IS <br />PER CEC 690.7. <br />10. CONDUCTORS ARE SIZED PER WIRE <br />AMPACITY TABLE CEC 310.15(B)(16). <br />ELECTRICAL NOTESSINGLE LINE DIAGRAM: DC SYSTEM SIZE - 6000W, AC SYSTEM SIZE - 4350W, CEC AC RATING:5405W <br />AC WIRE SIZING CALCULATIONS BASED OF FOLLOWING EQUATIONS >> <br />· REQUIRED CONDUCTOR AMPACITY: INVERTER OUTPUT CURRENT X #OF <br />INVERTERS = MAX CURRENT PER 690.8(A)(3) X 125% = MAX CURRENT PER <br />690.8(B)(1) <br />· CORRECTED AMPACITY CALCULATIONS: AMPACITY X TEMPERATURE DERATE <br />FACTOR X CONDUIT FILL DERATE = DERATED CONDUCTOR AMPACITY PER <br />690.8(B)(2) <br />· DERATED CONDUCTOR AMPACITY CHECK: MAX CURRENT PER 690.8(A)(3) <br /><DERATED CONDUCTOR AMPACITY <br />AC WIRE CALCULATIONS:- MATERIAL:COPPER & TEMPERATURE RATING:90°C <br />TAG ID REQUIRED CONDUCTOR AMPACITY CORRECTED AMPACITY CALCULATION DERATED CONDUCTOR AMPACITY CHECK <br />1 1.21 X 8 = 9.68 X 1.25 = 12.10A 30 X 0.87 X 1 =26.10A 12.10A <26.10A <br />2 1.21 X 8 = 9.68 X 1.25 = 12.10A 40 X 0.87 X 0.8 =27.84A 12.10A <27.84A <br />3 1.21 X 15 = 18.15 X 1.25 = 22.69A 40 X 0.87 X 1 =34.80A 22.69A <34.80A <br />4 (E)18A+(N)18.15 = 36.15 X 1.25 = 45.19A 75 X 0.87 X 1 =65.25A 45.19A <65.25A <br />CONDUIT SCHEDULE <br />TAG ID CONDUIT SIZE CONDUCTOR NEUTRAL GROUND <br />1 NONE (2) 12AWG ENPHASE Q CABLE <br />PER BRANCH CIRCUIT NONE (1) 6AWG BARE COPPER <br />2 3/4"EMT (4) 10AWG THHN/THWN-2 NONE (1) 8AWG THHN/THWN-2 <br />3 3/4"EMT (2) 10AWG THHN/THWN-2 (1) 10AWG THHN/THWN-2 (1) 8AWG THHN/THWN-2 <br />4 3/4"EMT (2) 6AWG THHN/THWN-2 (1) 6AWG THHN/THWN-2 (1) 8AWG THHN/THWN-2 <br />NOTE: <br />SUB PANEL RATING:100A, SUB FEEDER RATING RATING:60A <br />120% RULE: (100AX1.2)-60A=60A =>ALLOWABLE BACKFEED IS 60A <br />OCPD CALCULATIONS: <br />INVERTER OVERCURRENT PROTECTION= <br />INVERTER O/P I X CONTINUOUS LOAD(1.25)X #OF INVERTERS <br />=1.21x15x1.25=22.69 A =>REQUIRED BREAKER =30A <br />=(N)30A+(E)30A =>PV BREAKER=60A <br />ALLOWABLE BACKFEED 60A =>60A PV BREAKER <br />THE DESIGNED INTERCONNECTION MEETS THE 705.12(B)(2) REQUIREMENTS. <br />ELECTRICAL CALCULATION <br />MICRO INVERTER SPECIFICATIONS <br />MODEL <br />ENPAHSE <br />IQ8PLUS-72-2-US(240V)(SI- <br />1) <br />POWER RATING 290W <br />MAX OUTPUT CURRENT 1.21A <br />CEC WEIGHTED EFFICIENCY 97% <br />MAX NO OF MICRO <br />INVERTERS/BRANCH 13 <br />MAX DC VOLTAGE 60V <br />NOTE: <br />1. EACH MICRO INVERTER IS RAPID SHUTDOWN COMPLIANT. <br />D <br />Service meter was replaced without inspections. <br />A new Service Meter permit is required. <br />Inspector to examine and determine approval or <br />corrections. <br />Existing PV system was never inspected nor <br />approved. <br />A new permit for the existing PV system is <br />required. <br />Inspector to verify system and determine approval <br />or corrections. <br />1238 S Cypress - <br />2017784102/16/23