Laserfiche WebLink
AC <br />D <br /> I <br />N <br />V <br />MS <br />P <br />UM <br />JB <br />3'-0" 24'-4"7'-5" <br />1 <br />' <br />- <br />6 <br />" <br />1 <br />1 <br />' <br />- <br />7 <br />" <br />4' <br />- <br />7 <br />" <br />9'-5"10'-5" 10'-9" <br />REV <br />SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />ANSI B <br />11" X 17" <br />DATE DESCRIPTION <br />REVISIONS <br />Signature with Seal <br />PROJECT NAME & ADDRESS <br />PV-2 <br />PROJECT ID <br />CO <br />S <br />M <br />E <br />NU <br />N <br />E <br />Z <br />- <br />G <br />A <br />R <br />C <br />I <br />A <br />1 <br />3 <br />1 <br />0 <br /> <br />W <br /> <br />1 <br />2 <br />T <br />H <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />, <br />U <br />S <br />A <br />FRESH08/10/2022 ORIGINAL PLAN <br />2065 W OBISPO AVE #102 <br />GILBERT, AZ 85233 USA <br />866-572-2637 <br />LIC # CA-1019100 <br />ABHISHEK MAHESH <br />ROOF PLAN & <br />MODULES <br />ROOF DESCRIPTION <br />ROOF TYPE COMP SHINGLE /ROLLED <br />COMP ROOF <br />ROOF ROOF TILT AZIMUTH RAFTERS <br />SIZE <br />RAFTERS <br />SPACING <br />#1 10°180° 2"x4"24" o.c. <br />#2 20°180° 2"x4"24" o.c. <br />LEGEND <br />- JUNCTION BOX <br />MSP - MAIN SERVICE PANEL <br />- VENTS, DISH (ROOF OBSTRUCTION) <br />- ROOF ATTACHMENT <br />- RAFTERS <br />- CONDUIT <br />- UTILITY METER <br />SCALE: 3/32" = 1'-0" <br />- SOLAREDGE OPTIMIZER <br />MODULE TYPE, DIMENSIONS & WEIGHT <br />ACD - AC DISCONNECT <br />- INVERTER <br />1 <br />PV-2 <br />NUMBER OF MODULES = 17 MODULES <br />MODULE TYPE = LONGI SOLAR LR4-60HPB 355M 355W MODULES <br />MODULE WEIGHT = 42.99 LBS / 19.5 KG. <br />COMPONENT WEIGHT: 1.5 LBS. PER MODULE <br />TOTAL DEAD LOAD: 756.33 LBS. <br />POINT LOAD PER STANDOFF.: 756.33 LBS / 38 STANDOFF = 19.90 LBS <br />MODULE DIMENSIONS = 69.09"x 40.87" = 19.61 SF <br />UNIT WEIGHT OF ARRAY = 2.27 PSF <br />UM <br />JB <br />INV <br />ARRAY AREA WITH TOTAL ROOF AREA <br />ROOF # OF <br />MODULES <br />ARRAY AREA <br />(Sq. Ft.) <br />TOTAL <br />ROOF <br />AREA <br />(Sq. Ft.) <br />ROOF <br />AREA <br />COVERED <br />BY ARRAY <br />(%) <br />#1 14 274.53 570.76 48.10 <br />#2 3 58.83 445.38 13.21 <br />ROOF PLAN & MODULES <br />PAGE 2 OF 21 <br />ARRAY AREA WITH WHOLE ROOF AREA <br />ROOF # OF <br />MODULES <br />ARRAY AREA <br />(Sq. Ft.) <br />TOTAL <br />ROOF <br />AREA <br />(Sq. Ft.) <br />ROOF <br />AREA <br />COVERED <br />BY ARRAY <br />(%) <br />#1-2 17 333.35 2871.31 11.61 <br />LONGI SOLAR <br />LR4-60HPB 355M <br /> 355W MODULES <br />40.87" <br />69 <br />. <br />0 <br />9 <br />" <br />(17) SOLAREDGE POWER <br />OPTIMIZER S-440 <br />(N) CHIKOUSA 7 RAILS <br />RACKING SYSTEM <br />(8) CHIKOUSA COMPOSITION <br />L-FOOT ATTACHMENTS @48"O.C. <br />(E) FRONT OF RESIDENCE <br />W 12TH ST <br />3/4" EMT CONDUIT <br />RUN ON ROOF <br />(N) JUNCTION BOX <br />(E) BACK OF RESIDENCE <br />ROOF #1 <br />TILT - 10° <br />AZIM. - 180° <br />(E) MAIN SERVICE PANEL, <br />200A RATED, 240V, <br />(SURFACE MOUNT) <br />(E) UTILITY METER <br />(N) AC DISCONNECT <br />(N) SOLAREDGE TECHNOLOGY : <br />SE5000H-US INVERTER <br />INTEGRATED RAPID SHUTDOWN <br />ROOF #01 <br />(14) LONGI SOLAR LR4-60HPB <br />355M 355W MODULES <br />ROOF ACCESS POINT <br />ROOF #02 <br />(03) LONGI SOLAR LR4-60HPB <br />355M 355W MODULES <br />(N) UNIRAC RAIL <br />RACKING SYSTEM <br />(30) UNIRAC STANDOFF ATTACHMENT <br />WITH CHEMLINK E-CURB FLASHINGS <br />@48" O.C. <br />36 <br />" <br /> <br />F <br />I <br />R <br />E <br /> <br />S <br />E <br />T <br />B <br />A <br />C <br />K <br />18" <br /> FIRE <br />SET <br />B <br />A <br />C <br />K <br />18" FIRE <br />SET <br />BACK <br />18" FIRE SETBACK <br />18" FIRE SETBACK <br />18" <br /> FIRE <br /> <br />SETBACK <br />18" <br /> FIRE <br /> <br />SETB <br />A <br />CK <br />1 <br />8 <br />" <br /> <br />F <br />I <br />R <br />E <br /> <br />S <br />E <br />T <br />B <br />A <br />C <br />K <br />1 <br />8 <br />" <br /> <br />F <br />I <br />R <br />E <br /> <br />S <br />E <br />T <br />B <br />A <br />C <br />K <br />18" FIRE SETBACK <br />18" FIRE SETBACK <br />18" FIRE SETBACK <br />18" FIRE SETBACKROOF #2 <br />TILT - 20° <br />AZIM. - 180° <br />Structural <br />Only <br />1310 W 12th St <br />10/11/22