Laserfiche WebLink
SCOPE OF WORK: <br />INSTALL (25) SUNPOWER SPR-M425-H-AC SOLAR ELECTRIC <br />MODULES ON THE EXISTING 1ST STORY COMPOSITION <br />ROOF. INSTALL ASSOCIATED MOUNTING HARDWARE, <br />JUNCTION BOXES, CONDUIT, CONDUCTORS AND <br />GROUNDING. INSTALL (1) LOAD CENTER, (1) FUSED AC <br />DISCONNECT, AND CONNECT TO SCE INSTALLED GMA. <br />HOMEOWNER: HUU NGUYEN <br />PH: 714.717.0992 <br />ADDRESS: 1425 N. KING STREET <br />SANTA ANA, CA 92706 <br />DATE: 5/17/22DATE: 5/17/22 <br />ECOSOLAR USA <br />ELECTRICAL LLC <br />13962 SEABOARD CIRCLE <br />GARDEN GROVE, CA 92840 <br />PH: 714.265.9077 DAVID Q HOANG C10 - 1045300 <br />VICINITY MAP <br />NGUYEN <br />RESIDENCE <br />SHEET INDEX: <br />SHEET 1 PROJECT INFO, VICINITY MAP, NOTES, SCOPE OF WORK <br />SHEET 2 SITE/ROOF PLAN, ELEVATION DETAIL <br />SHEET 3 ELECTRIC LINE DRAWING, GROUNDING DETAIL <br />SHEET 4 CALCULATIONS, SIGNS <br />ATTACHED MODULE, INVERTER, MOUNTING HARDWARE SPEC SHEETS, <br />STRUCTURAL REPORT <br />NTS <br />SHEET <br />NOTICE: <br />ANY CHANGES TO OR USES OF THESE DOCUMENTS/DRAWINGS WITHOUT THE <br />WRITTEN CONSENT OF JENNIFER KEMME OR SCOTT HARRIS ARE STRICTLY PROHIBITED. <br />1 OF 4 <br />PLANS PREPARED BY: <br />JENNIFER KEMME <br />PH: 909.748.1300 <br />GENERAL NOTES: <br />1. THIS SYSTEM COMPLIES WITH THE 2019 CRC, 2019 CBC, 2019 CFC, AND THE 2019 <br />CEC. <br />2. THE SYSTEM WILL NOT BE TURNED-ON UNTIL THE SERVING UTILITY COMPANY <br />HAS BEEN NOTIFIED. <br />3. THE INSTALLED SOLAR SYSTEM HAS A DISTRIBUTED WEIGHT LESS THAN 4 PSF. <br />4. THE CONCENTRATED LOAD FOR EACH VERTICAL SUPPORT IS LESS THAN 40 LBS. <br />5. ALL PV EQUIPMENT IS LISTED BY A RECOGNIZED TESTING LAB. INVERTERS ARE <br />UL 1741 COMPLIANT. <br />6. THE BACKFED BREAKER WILL BE LOCATED AT THE OPPOSITE END OF THE BUS <br />FROM THE MAIN BREAKER. <br />7. CONDUCTORS ARE 90° C RATED COPPER WIRE. <br />8. ANY CONDUCTORS EXPOSED TO SUNLIGHT ARE LISTED AS SUNLIGHT <br />RESISTANT. <br />9. IF DC CONDUCTORS ARE RUN INSIDE THE BUILDING, THEY WILL BE CONTAINED <br />IN A METAL RACEWAY. <br />10. ANY CONDUCTORS BETWEEN SEPARATE ARRAYS ON THE ROOF WILL BE <br />PROTECTED IN CONDUIT. <br />11. THE EQUIPMENT GROUNDING CONDUCTOR ON THE ROOF WILL BE PROTECTED <br />FROM PHYSICAL DAMAGE. IT WILL BE TUCKED NEATLY UNDER THE MODULES <br />AND RAILS AND SECURED IN PLACE. <br />12. THE MODULES WILL BE ATTACHED TO THE EQUIPMENT GROUNDING <br />CONDUCTOR IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. <br />13. ALL EXTERIOR CONDUIT, FITTINGS AND BOXES ARE RAIN-TIGHT AND APPROVED <br />FOR USE IN WET LOCATIONS. <br />14. CLEARANCES AROUND ALL ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN <br />ACCORDANCE WITH CEC 110.26. <br />15. SOLAR MODULES WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL OR <br />BUILDING ROOF VENTS. <br />16. IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE <br />GROUNDING ELECTRODE SYSTEM, A GROUNDING ELECTRODE SYSTEM WILL BE <br />INSTALLED PER CEC 250.50. THE ELECTRICAL SERVICE WILL BE BONDED TO THE <br />WATER AND GAS PIPING PER SECTION 250.104 OF THE CEC. <br />17. A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH CAL-OSHA <br />REGULATIONS. <br />89026PV <br />(25) SUNPOWER SPR-M425-H-AC <br />AC MODULES <br />PEAK POWER = 425 W <br />MAX OUTPUT CURRENT = 1.60 A <br />MAX OCPD = 20 A <br />MAX NUMBER IN SERIES = 10 <br />TEMP. COEFF. OF POWER = -0.29%/°C <br />DIMENSIONS = 73.7" X 40.6" X 1.3" <br />WEIGHT = 48.0 LBS <br />PHOTOVOLTAIC SOLAR PROJECT INFORMATION: <br />SYSTEM SIZE: 10.625 kW (DC) <br />MODULES: <br />ARRAY:INSTALLED WEIGHT = 2.8 PSF <br />ROOF COVERAGE = 520 SF, <br />ARRAYS COVER 33% OF TOTAL ROOF AREA <br />MOUNTING HARDWARE: SUNPOWER INVISIMOUNT RAIL <br />UNIRAC FLASHED FOOT ATTACHMENTS <br /> 5 16" STAINLESS STEEL LAG BOLTS @ <br />64" OC OR LESS WITH A MINIMUM OF <br />21 2" PENETRATION INTO ROOF RAFTERS <br />EXISTING ROOF INFO: 1 STORY, COMPOSITION SHINGLE <br />2 X 6 RAFTERS @ 16" OC <br />Bldg permi#101111031 <br />Elect permit#20176668 <br />Permits issued on 7/21/2022 <br />1425 N King St - <br />2017666807/25/22