My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1451 S Cypress - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Cypress Ave
>
1451 S Cypress Ave
>
1451 S Cypress - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2025 1:35:58 PM
Creation date
5/30/2025 8:00:50 AM
Metadata
Fields
Template:
Plan
Permit Number
20176187
101110431
101112126
Full Address
1451 S Cypress Ave
Document Relationships
101110431 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Cypress Ave\1451 S Cypress Ave
101112126 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Cypress Ave\1451 S Cypress Ave
20176187 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Cypress Ave\1451 S Cypress Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
HOMEOWNER: HUYNH THE LE <br />PH: 714.512.7810 <br />ADDRESS: 1451 CYPRESS AVENUE <br />SANTA ANA, CA 92707 <br />DATE: 9/9/22DATE: 9/9/22 <br />ECOSOLAR USA <br />ELECTRICAL LLC <br />13962 SEABOARD CIRCLE <br />GARDEN GROVE, CA 92840 <br />PH: 714.265.9077 DAVID Q HOANG C10 - 1045300 <br />SCO3E O) :OR. <br />INSTALL (26) SUNPOWER SPR-X20-327-E-AC SOLAR ELECTRIC <br />MODULES ON THE EXISTING 1ST STORY COMPOSITION ROOF. <br />INSTALL ASSOCIATED MOUNTING HARDWARE, JUNCTION <br />BOXES, CONDUIT, CONDUCTORS AND GROUNDING. INSTALL <br />(1) LOAD CENTER, AND INSTALL OCPD IN MAIN SERVICE <br />PANEL. DE-RATE MAIN BREAKER TO 175 AMP. <br />SERVICE POINT & UTILITY METERING <br />CAUTION: <br />POWER TO THIS BUILDING IS ALSO <br />SUPPLIED FROM THE FOLLOWING SOURCES <br />WITH DISCONNECTS AS SHOWN. <br />ADDRESS: 1451 CYPRESS AVENUE, SANTA ANA, CA 92707 <br />SOLAR ARRAY <br />(ON ROOF)N <br />TO BE INSTALLED ON THE OUTSIDE COVER <br />OF THE MAIN SERVICE DISCONNECT: <br />S+EET <br />1OTICE <br />A1 < C+A1*ES TO OR USES O ) T+ESE <br />'OCU0E1TS'RA:I1*S :IT+OUT T+E <br />:RITTE1 CO1SE1T O) -E11I)ER .E00E OR <br />SCOTT +ARRIS ARE STRICTL< 3RO+I%ITE' <br /> O) <br />PLANS PREPARED BY: <br />JENNIFER KEMME <br />PH: 909.748.1300 <br />89008PVR1 <br />S<STE 0 CALCULATIO1S <br />NUMBER OF MODULES IN CIRCUIT # 1 = 9 <br />MODULE MAX OUTPUT CURRENT = 1.31 A <br />(9) (1.31 A) (1.25) = 14.74 A [Ic], USE 20 A BREAKER <br />TOTAL NUMBER OF MODULES = 26 <br />(26) (1.31 A) (1.25) = 42.58 A [I], USE 50 A BREAKER <br />MAIN SERVICE PANEL BUS RATING = 200 A <br />MAIN SERVICE PANEL MAIN OCPD = 175 A <br />175 A + 50 A SOLAR OCPD = 225 A <br />200 A BUS (1.2) = 240 A <br />225 A < 240 A, OK <br />S<STE 0 SI*1A*E <br />ALL SIGNAGE SHALL BE REFLECTIVE, UV RESISTANT <br />PLASTIC, RED IN COLOR WITH WHITE LETTERING, AND <br />ATTACHED WITH WEATHERPROOF ADHESIVE OR <br />OTHER APPROVED METHOD. ALL LETTERS SHALL BE A <br />MINIMUM OF 3 8" HEIGHT AND ALL CAPITALIZED. <br />ALL CONDUIT, JUNCTION BOXES AND OTHER ENCLOSURES <br />SHALL BE MARKED AT 10' MAX INTERVALS AND AT ALL <br />BENDS, TERMINATIONS, SPLICES OR CONNECTIONS WITH <br />"WARNING: PHOTOVOLTAIC POWER SOURCE". <br />WARNING <br />ELECTRIC SHOCK HAZARD <br />DO NOT TOUCH TERMINALS <br />TERMINALS ON BOTH THE LINE <br />AND LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />TO BE INSTALLED AT ALL SERVICEABLE PANELS <br />OR BOXES AND AT ALL DISCONNECTS: <br />RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM <br />RATED AC OUTPUT CURRENT = 42.58 A <br />NOMINAL OPERATING AC VOLTAGE = 240 V <br />TO BE INSTALLED NEXT TO THE <br />SOLAR BREAKER: <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE <br />"OFF" POSITION TO <br />SHUT DOWN PV SYSTEM <br />AND REDUCE <br />SHOCK HAZARD <br />IN THE ARRAY <br />SOLAR ELECTRIC <br />PV PANELS <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />TO BE INSTALLED ON THE FRONT OF THE <br />MAIN SERVICE DISCONNECT: <br />"SOLAR PV SYSTEM EQUIPPED WITH RAPID <br />SHUTDOWN" SHALL BE BLACK LETTERING <br />ON YELLOW BACKGROUND. THE <br />REMAINDER OF THE SIGN SHALL BE BLACK <br />LETTERING ON WHITE BACKGROUND. <br />:IRE CALCULATIO1S <br />FROM THE MODULES TO THE LOAD CENTER: <br />AMBIENT TEMPERATURE = 34°C <br />TEMPERATURE ADDER FOR CONDUIT OFFSET NOT FROM ROOF = 33°C <br />ADJUSTMENT FACTOR PER TABLE 310.15(B)(2)(a) FOR 90°C INSULATED CONDUCTOR AT <br />34°C + 33°C = 67°C = 0.58 <br />Ic = 14.74 A <br />14.74 A/0.58 = 25.41 A <br />NUMBER OF CURRENT CARRYING CONDUCTORS IN CONDUIT = 6 <br />ADJUSTMENT FACTOR PER TABLE 310.15(B)(3)(a) FOR CONDUIT FILL (4-6 CONDUCTORS IN <br />CONDUIT) = 0.80 <br />25.41 A/0.80 = 31.76 A <br />SELECT WIRE SIZE WITH AMPACITY GREATER THAN 31.76 A, <br />USE 10 AWG THWN-2 COPPER WIRE WITH AN AMPACITY OF 40 A <br />SELECT CONDUIT FOR (6) 10 AWG THWN-2 & (1) 10 AWG GROUND = 3 4" EMT CONDUIT <br />FROM THE LOAD CENTER TO THE MAIN SERVICE PANEL: <br />ADJUSTMENT FACTOR PER TABLE 310.15(B)(2)(a) FOR 90°C INSULATED CONDUCTOR AT <br />34°C = 0.96 <br />I = 42.58 A <br />42.58 A/0.96 = 44.35 A <br />SELECT WIRE SIZE WITH AMPACITY GREATER THAN 44.35 A, <br />USE 8 AWG THWN-2 COPPER WIRE WITH AN AMPACITY OF 55 A <br />SELECT CONDUIT FOR (3) 8 AWG THWN-2 & (1) 8 AWG GROUND = 3 4" EMT CONDUIT <br />PV SYSTEM DISCONNECT <br />FOR UTILITY OPERATION <br />1451 S. Cypress <br />09/27/22
The URL can be used to link to this page
Your browser does not support the video tag.