1508 E Washington Ave - Plan
PBA
>
Building
>
ProjectDox
>
W
>
Washington Ave
>
1508 E Washington Ave
>
1508 E Washington Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2025 1:35:58 PM
Creation date
5/30/2025 8:00:50 AM
Metadata
Fields
Template:
Plan
Permit Number
20178303
20178552
101113268
Full Address
1508 E Washington Ave
Document Relationships
101113268 - Permit
(Permit - Plan)
Path:
\Building\Permits\W\Washington Ave\1508 E Washington Ave
20178303 - Permit
(Permit - Plan)
Path:
\Building\Permits\W\Washington Ave\1508 E Washington Ave
20178552 - Permit
(Permit - Plan)
Path:
\Building\Permits\W\Washington Ave\1508 E Washington Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Page 2 of 2 <br />D. Solar Panel Anchorage <br />1. The solar panels shall be mounted in accordance with the most recent Everest Solar Systems <br />installation manual. If during solar panel installation, the roof framing members appear unstable or <br />deflect non-uniformly, our office should be notified before proceeding with the installation. <br />2. The maximum allowable withdrawal force for a 5/16 lag screw is 235 lbs per inch of penetration as <br />identified in the National Design Standards (NDS) of timber construction specifications. Based on <br />a minimum penetration depth of 2½, the allowable capacity per connection is greater than the <br />design withdrawal force (demand). Considering the variable factors for the existing roof framing <br />and installation tolerances, the connection using two 5/16 diameter lag screw with a minimum of <br />2½ embedment will be adequate and will include a sufficient factor of safety. <br />3. Considering the wind speed, roof slopes, size and spacing of framing members, and condition of <br />the roof, the panel supports shall be placed no greater than 72 on center. <br />4. Panel supports connections shall be staggered to distribute load to adjacent framing members. <br />Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing <br />roof system will adequately support the additional loading imposed by the solar system. This evaluation is in <br />conformance with the 2019 CRC, current industry standards and practice, and is based on information supplied <br />to us at the time of this report. <br />Should you have any questions regarding the above or if you require further information do not hesitate to <br />contact me. <br />Very truly yours, <br />Scott E. Wyssling, PE <br />California License No. 83664 <br />Signed 8/22/2022 <br />1508 E Washington <br />Ave - 2017830312/30/22