My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1605 E Wellington Ave - Plan
PBA
>
Building
>
ProjectDox
>
W
>
Wellington Ave
>
1605 E Wellington Ave
>
1605 E Wellington Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/13/2025 12:54:51 AM
Creation date
5/30/2025 8:00:50 AM
Metadata
Fields
Template:
Plan
Permit Number
20174635
101108408
Full Address
1605 E Wellington Ave
Street Number
1605
Street Direction
E
Street Name
Wellington
Street Suffix
Ave
Document Relationships
101108408 - Permit
(Permit - Plan)
Path:
\Building\Permits\W\Wellington Ave\1605 E Wellington Ave
20174635 - Permit
(Permit - Plan)
Path:
\Building\Permits\W\Wellington Ave\1605 E Wellington Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
McPherson Engineering By: J.J. <br />Date: 10/1/21 <br />Rooftop Solar Panels Wind Pressures (Section 29.4, ASCE 7‐16) <br />Vult = 130 mph Kzt = 1.00 (sec 26.8.2) h = 15 ft <br />Exposure Category = C Kz = 0.85 (sec 26.10.1) <br />Roof Zone = 2 Kd = 0.85 (sec 26.6) <br />Panel θ = 7‐27 deg Ke = 1.00 (sec 26.9) <br />qh = 0.00256 Kz Kzt Kd Ke V2 qh = 31.26 (eq. 26.10‐1) <br />γE = 1.5 FIG 29.4‐7)γc = 1.00 (fig 29.4‐7) hpt = 0 ft <br />γa = 0.68 (fig 29.4‐8)γp = 0.9 (fig 29.4‐7) ω = 0.00 deg <br />GPp = ‐2 uplift GCrm = 1.4 uplift <br />p = qh (GPp) γE γa (eq 29.4‐7)p = qh (GCrn) γE γC γp (eq 29.4‐6) <br />p = ‐63.8 p.s.f.p = 59.0 p.s.f. <br />Check Anchorage to Existing Structure <br />0.6DL ‐ 0.6W controlling load combination (eq. 16‐15 for ASD) <br />DL = 2.8 p.s.f.dead load of panel (inlcuding rack system) <br />W = 63.8 p.s.f.wind load normal to face of panel <br />Arealag = 19.9 sq. ft.area tributary to each anchor <br />SPanc = 6.0 ft.spacing of anchors <br />Puplift = Arealag (0.6DL - 0.6W) = 728.5 lbs total uplift on anchor <br />Material = DFL lumber anchor material <br />Dialag = 5/16 in. diameter of screw <br />Penlag = 2.5 in. min. penetration to existing framing <br />Wlag = 266 lb/in. withdrawal load per in. of penetration per NDS Table 11.2A <br />CD = 1.6 load duration factor for wind per NDS Table 2.3.2 <br />Ct = 0.8 temperature factor per NDS Table 2.3.3 <br />Noscrews = 1 number of screws in withdrawal <br />Pallow = Penlag (Wlag CD Ct) * Noscrews = 851.2 lbs total allowable withrawal on anchor <br />Puplift <br />Pallow <br />Anchorage = USE (1) 5/16IN. DIA. LAG SCREW(S) AT 6FT. MAX. O.C. W/ 2.5IN. MIN. PENETRATION <br />0.86 < 1.00 Anchor is OK! <br />Wind Uplift Anchorage <br />Flush Mounted Panels ‐ ASCE Section <br />29.4.4 (where applicable) <br />Flat Roof Panels ‐ ASCE Section 29.4.3 <br />(where applicable) <br />= <br />10/1/2021 11:33 AM <br />6 of 7 <br />©McPherson Engineering <br />1605 E Wellington <br />Ave11/03/21