',6&/$,0(581$87+25,=('86(2)7+,6'5$:,1*6(7
<br />:,7+287:5,77(13(50,66,21)520,1),1,7<62/$5,1&,6,1
<br />9,2/$7,212)86&23<5,*+7/$:6$1':,//%(68%-(&772
<br />&,9,/'$0$*(6$1'3526(&87,216
<br />INFINITY SOLAR, INC.
<br />2460 N GLASSELL ST. #A
<br />ORANGE, CA 92865
<br />PHONE: (714) 880-8089
<br />LIC NO.: C10 #824287
<br />.$<6<('$
<br />
<br />,1),1,7<62/$5,1&
<br />
<br />A. RESIDENTIAL ROOF MOUNTED PHOTOVOLTAIC SYSTEM SHALL
<br />BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURES
<br />SPECIFICATIONS AND THE 2019 CALIFORNIA RESIDENTIAL CODE,
<br />SECTIONS R314, R909 AND R918, 2019 CALIFORNIA ELECTRICAL
<br />CODE AND 2019 CALIFORNIA FIRE CODE.
<br />B. CONTRACTORS SHALL BE PRESENT DURING ALL INSPECTIONS.
<br />C. THE ROOF ACCESS POINT REQUIRING A LADDER SHALL NOT
<br />BE LOCATED OVER A WINDOW, DOOR OR LOCATED WHERE IT
<br />CONFLICTS WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE
<br />LIMBS, WIRES OR SIGNS [CRC 324.7.1].
<br />D. A LADDER SHALL BE PROVIDED AND SECURED TO THE
<br />STRUCTURE AT THE APPROVED ROOF ACCESS POINT PER NOT
<br />"C" ABOVE WITH A CAL OSHA APPROVED DEVICE DURING ALL
<br />INSPECTIONS.
<br />&$/,)251,$%8,/',1*&2'(
<br />&$/,)251,$5(6,'(17,$/&2'(
<br />&$/,)251,$(/(&75,&$/&2'(
<br />&$/,)251,$),5(&2'(
<br />&$/,)251,$0(&+$1,&$/&2'(
<br />&$/,)251,$*5((1&2'(
<br />&$/,)251,$3/80%,1*&2'(
<br />&$/,)251,$(1(5*<&2'(
<br />$1<27+(5 /2&$/$1'081,&,3$/&2'(6
<br />*(1(5$/127(6
<br />2:1(5
<br />1$0(-26(6$/$=$5
<br />3+21(
<br />(0$,/$'VDOD]DUMF#\DKRRFRP
<br />352-(&70$1$*(5
<br />1$0(
<br />3+21(
<br />&2175$&725
<br />1$0(
<br />3+21(
<br />$87+25,7,(6+$9,1*-85,6',&7,21
<br />%8,/',1*6$17$ $1$
<br />=21,1*6$17$ $1$
<br />87,/,7<6&(
<br />'(6,*163(&,),&$7,216
<br />2&&83$1&<58
<br />&216758&7,219%
<br />=21,1*5(6,'(17,$/
<br />612: /2$'36)
<br />:,1'(;32685(&
<br />:,1'63(('03+
<br />522)685)$&(64)7
<br />39&29(5$*(64)7
<br />122)6725,(6
<br />),5(635,1./(5612
<br />/27,1)250$7,21
<br />$31
<br />/27$5($64)7
<br />/,9,1*$5($64)7
<br />$5
<br />REV: DESCRIPTION: BY: DATE:
<br />PAPER SIZE: 11" X 17" (ANSI B)
<br />DRAWING TITLE:
<br />DRAWN BY:
<br />CHECKED BY:
<br />DATE:
<br />DRAWING NO:REVISION:
<br />4/24/2022
<br />ENGINEER OF RECORD
<br />$)
<br />NEW PV SYSTEM: 4.400 kWp
<br />JOSE
<br /> SALAZAR
<br />1920 S KILSON DR,
<br />SANTA ANA, CA 92707
<br />APN: 01409105
<br />PV.01
<br />,167$//(5 127(6
<br />COVER SHEET
<br />N
<br />E
<br />S
<br />W
<br />PV.01
<br />01 AERIAL PHOTO
<br />NTS
<br />352-(&7,1)250$7,21
<br />$33/,&$%/(&2'(6
<br />NEW PV SYSTEM FOR
<br />SALAZAR RESIDENCE
<br />1920 S KILSON DR, SANTA ANA, CA 92707
<br />SYSTEM SIZE: 4.400 kWp
<br />CEC POWER OUTPUT: 4.070 kWp
<br />APN: 01409105
<br />'&6<67(06,=(N: $&6<67(06,=(N:
<br />02'8/(5(&62/$55(&$$385(%/$&.
<br />0,&52,19(57(5(13+$6(,4$86
<br />02817(9(5)/$6+(&203.,7
<br />5$,/,1*(9(5(675$&.,1*;5$,/6
<br />06383*5$'(12
<br />$//:25. 6+$//&203/<:,7+$33/,&$%/(/2&$/081,&,3$/
<br />&2'(6$1'720$18)$&785(56 /,67,1*6$1',167$//$7,21
<br />,16758&7,2167+(3962/$56<67(0:,//%(
<br />,17(5&211(&7('$1'23(5$7(',13$5$//(/:,7+7+(
<br />87,/,7<(/(&75,&$/*5,'3(5 7+(5(48,5(0(1762)7+(
<br />87,/,7<$1'$33/,&$%/(&2'(67+(3962/$56<67(0,6
<br />'(6,*1(',1&203/,$1&(:,7+&(&5$3,'6+87'2:1
<br />6&23(2):25.
<br />6+((7/,677$%/(
<br />6+((7180%(5 6+((77,7/(
<br />39&29(5 6+((7
<br />396,7(3/$1
<br />39522)3/$1
<br />39$77$&+0(173/$1
<br />39$66(0%/<'(7$,/6
<br />39/,1(',$*5$0
<br />39'(6,*17$%/(6
<br />393/$&$5'6
<br />393/$&$5'0$3
<br />390,&52,19(57(5 0$3
<br />6663(&,),&$7,216+((76
<br />&20%,1((;,67,1*%5($.(56720$.(5220)25 62/$5
<br />%5($.(5
<br />Bldg permit# 101110580
<br />Elect permit#20176281
<br />Issued on 5/31/22
<br />1920 S Kilson Dr
<br />05/31/22
|