Laserfiche WebLink
RO <br />O <br />F <br /> <br />S <br />L <br />O <br />P <br />E <br />9 <br />9 <br />SEE PVS-1 FOR DIMENSION <br />6 <br />7 <br />17 <br />19 20 21 <br />SEE DATA SHEET <br />19 20 21 <br />4 5 8 <br />3 12 13 <br />BILL OF MATERIALS <br />EQUIPMENT DESCRIPTION QTY <br />ATTACHMENTS <br />RAILS <br />RAIL SPLICE <br />MID CLAMPS <br />END CLAMPS <br />GROUNDING LUGS <br />UNIRAC FLASHLOC <br />UNIT <br />PIECES <br />PIECES <br />RAIL SPLICE <br />MID CLAMPS <br />END CLAMPS <br />GROUNDING LUGS <br />PIECES <br />PIECES <br />PIECES <br />PIECES <br />14 <br />5 <br />4 <br />18 <br />4 <br />1 <br />1. ROOF MATERIAL: ROLLED COMP <br />2. ROOF STRUCTURE: <br />3. ATTACHMENT TYPE: UNIRAC FLASHLOC <br />4. MODULE MANUFACTURER: Q-CELLS <br />5. MODULE MODEL: Q.PEAK DUO BLK ML-G10+ 400 <br />6. MODULE LENGTH: 74 <br />7. MODULE WIDTH: 41.1 <br />8. MODULE WEIGHT: 48.5 <br />9. MIN. FIRE OFFSET: NONE <br />10. RAFTER SPACING: 24 IN. O.C. <br />11. RAFTER SIZE: 2"X8" NOMINAL <br />12. LAG BOLT DIAMETER: 5/16 IN. <br />13. LAG BOLT EMBEDMENT: 2-1/2 IN. <br />14. TOTAL # OF ATTACHMENTS: 14 <br />15. TOTAL AREA: 3023.7 SQ. FT. <br />16. MAX. HORIZONTAL STANDOFF: 72 IN. <br />17. MAX. VERTICAL STANDOFF: <br />LANDSCAPE: 26 IN., PORTRAIT: 32 IN. <br />18. STANDOFF STAGGERING: YES <br />20. RAIL MODEL: XR-10 RAIL <br />21. RAIL WEIGHT: 0.436 PLF. <br />22. MODULE CLEARANCE: 3 IN. MIN., 6 IN. MAX. <br />UNDER PURLINS/BRACING <br />TAG DESCRIPTION : <br />22 <br />19. RAIL MANUFACTURER: IRONRIDGE <br />IRONRIDGE XR-10 RAIL <br />CS <br />L <br />B <br /> <br /># <br /> <br />1 <br />0 <br />4 <br />9 <br />1 <br />0 <br />8 <br />(8 <br />5 <br />5 <br />) <br />7 <br />7 <br />5 <br />- <br />8 <br />7 <br />7 <br />5 <br />CA <br />L <br />I <br />F <br />O <br />R <br />N <br />I <br />A <br /> <br />S <br />T <br />A <br />T <br />E <br />EN <br />E <br />R <br />G <br />Y <br /> <br />I <br />N <br />C <br />. <br />NA <br />M <br />E <br />: <br /> <br />I <br />R <br />M <br />A <br /> <br />G <br />O <br />N <br />Z <br />A <br />L <br />E <br />Z <br />AD <br />D <br />R <br />E <br />S <br />S <br /> <br />: <br /> <br />1 <br />9 <br />2 <br />7 <br /> <br />W <br /> <br />C <br />A <br />M <br />D <br />E <br />N <br /> <br />P <br />L <br />CI <br />T <br />Y <br /> <br />: <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />ST <br />A <br />T <br />E <br />, <br />Z <br />I <br />P <br /> <br />C <br />O <br />D <br />E <br />: <br /> <br />C <br />A <br />, <br />9 <br />2 <br />7 <br />0 <br />4 <br />AH <br />J <br /> <br />: <br /> <br />C <br />I <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />FI <br />N <br />A <br />N <br />C <br />E <br /> <br />T <br />Y <br />P <br />E <br />: <br /> <br />N <br />O <br />N <br />E <br />SO <br />L <br />A <br />R <br /> <br />P <br />E <br />R <br />M <br />I <br />T <br /> <br />P <br />A <br />C <br />K <br />A <br />G <br />E <br />4. <br />0 <br />0 <br />0 <br /> <br />k <br />W <br /> <br />D <br />C <br />2. <br />9 <br />0 <br />0 <br /> <br />k <br />W <br /> <br />A <br />C <br />MOUNTING DETAILS <br />SCALE:NTS <br />PVS-2 <br />SHEET <br />AL <br />T <br />N <br />A <br /> <br />E <br />N <br />E <br />R <br />G <br />Y <br /> <br />S <br />E <br />R <br />V <br />I <br />C <br />E <br />S <br />21 <br />6 <br />8 <br /> <br />W <br /> <br />G <br />R <br />O <br />V <br />E <br /> <br />P <br />K <br />W <br />Y <br />AM <br />E <br />R <br />I <br />C <br />A <br />N <br /> <br />F <br />O <br />R <br />K <br />, <br /> <br />U <br />T <br />. <br />84 <br />0 <br />0 <br />3 <br /> <br />8 <br />0 <br />1 <br />- <br />7 <br />3 <br />5 <br />- <br />5 <br />1 <br />2 <br />3 <br />RE <br />V <br /> <br />D <br />E <br />S <br />C <br />R <br />I <br />P <br />T <br />I <br />O <br />N <br />DA <br />T <br />E <br /> <br />D <br />B <br /> <br />C <br />B <br />R <br />E <br /> <br />V <br /> <br />I <br /> <br />S <br /> <br />I <br /> <br />O <br /> <br />N <br /> <br />S <br />EN <br />E <br />R <br />G <br />Y <br /> <br /> S <br />E <br />R <br />V <br />I <br />C <br />E <br />S <br />DE <br />S <br />I <br />G <br />N <br />E <br />D <br /> <br />B <br />Y <br />: <br />IN <br />S <br />T <br />A <br />L <br />L <br />E <br />D <br /> <br />B <br />Y <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />I <br />N <br />F <br />O <br />R <br />M <br />A <br />T <br />I <br />O <br />N <br />PROJECT NO : CSD-0250 <br />DATE DRAWN: 8.23.2022 <br />DRAWN BY : HO SUET BILARAN <br />DATE CHECKED : 8.23.2022 <br />CHECKED BY : MARY GRACE RAMOS <br />NOTE TO INSTALL: VERIFY THE ROOF FRAMING INFO BEFORE <br />INSTALLATION AND NOTIFY THE EOR IF THERE IS ANY INCONSISTENCY <br />BETWEEN SITE VERIFICATION AND FOLLOWINGS: 2x8 RAFTERS @ 24" OC <br />SPACING WITH MAX UNSUPPORTED SPAN EQUAL OR LESS THAN 16 FT. SP <br />1927 W Camden Pl <br />11/30/22