Laserfiche WebLink
ROOFTOP CONDUCTOR AMPACITIES DESIGNED IN <br />COMPLIANCE WITH ART. 690.8, TABLES 310.15(B)(2)(A), <br />310.15(B)(3)(A), 310.15(B)(3)(C), 310.15(B)(16), CHAPTER 9 <br />TABLE 4, 5, & 9. LOCATION SPECIFIC TEMPERATURE <br />OBTAINED FROM ASHRAE 2017 DATA TABLES. <br />NOTES <br />• DESIGNED ACCORDING TO AND ALL CODE CITATIONS <br />ARE RELEVANT TO THE 2019 CALIFORNIA ELECTRIC CODE. <br />• ALL SPECIFIED EQUIPMENT GROUNDING <br />DEVICES/COMPONENTS MUST BE LISTED FOR USE <br />• INVERTERS ARE EQUIPPED WITH RAPID SHUT DOWN. <br />• 690.11 DC ARCFAULT CIRCUIT PROTECTION. MICRO <br />INVERTERS ARE EXEMPT BECAUSE THERE ARE NO DC <br />STRINGS. <br />OTHER NOTES <br />ELECTRICAL NOTES <br />1. ALL SEAL TIGHT FLEXIBLE METAL CONDUIT (OR EQUIVALENT) TO BE BONDED TO GROUND AT COUPLINGS ON BOTH ENDS. <br />2. CONDUIT ENTRY/CONNECTION TO ELECTRICAL ENCLOSURES SHALL BE SUITABLE FOR GROUNDING AND SHALL BE SEALED AGAINST <br />ENVIRONMENT, SUCH AS WATER, INSECTS AND RODENTS. CONDUIT SHALL NOT ENTER FROM TOP OF ELECTRICAL EQUIPMENT IN OUTDOOR <br />LOCATIONS WITHOUT SITE-SPECIFIC APPROVAL FROM CALIFORNIA STATE DEVELOPMENT. IF GRANTED APPROVAL FOR TOP ENTRY, ONLY <br />RIGID CONDUIT WITH MEYERS HUBS TO BE USED. <br />3. PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS, CRIMPS, ETC. <br />4. ALL CONDUIT BEND RADII TO CONFORM TO THE CEC MINIMUM BEND RADII REQUIREMENTS. <br />5. MINIMUM CLEARANCE SHALL BE MAINTAINED PER CEC FOR ALL NEW EQUIPMENTS TO BE INSTALLED. <br />6. EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET CEC AND LOCAL UTILITY REQUIREMENTS. <br />7. COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED. <br />8. TYPE NM (ROMEX) CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC RUNS AND SHALL BE INSTALLED MEETING CEC REQUIREMENTS. <br />9. AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%. <br />10. RUN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS NO OTHER CONDUCTORS RUNNING THROUGH IT. <br />11. IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND INSTALLED BY A THIRD PARTY. <br />12. CONDUIT SIZE BASED ON 2 BENDS MAXIMUM. ANY ADDITIONAL BENDS MAY REQUIRE UPSIZE. <br />BILL OF MATERIALS <br />CATEGORY MAKE MODEL NUMBER REF QTY UNIT QTY/UNIT DESCRIPTION <br />MODULE PIECES 1 <br />INVERTER PIECES 1 <br />AC COMBINER PANEL ENPHASE X-IQ-AM1-240-3 1 PIECE 1 ENPHASE IQ COMBINER BOX 3 W/ ENVOY <br />WIRING ENPHASE Q-12-10-240 PIECES 1 ENPHASE Q CABLE Q-12-10-240 <br />WIRING ENPHASE Q-TERM-R 1 PIECE 1 ENPHASE Q CABLE TERMINATOR <br />WIRING ENPHASE Q-CONN-10F 1 PIECE 1 ENPHASE Q-CONN-10F IQ INVERTER FIELD WIREABLE FEMALE CONNECTOR KIT <br />WIRING ENPHASE Q-CONN-10M 1 PIECE 1 ENPHASE Q-CONN-10M IQ INVERTER FIELD WIREABLE MALE CONNECTOR KIT <br />WIRING GEN-6-AWG-BARE-CU FEET 1 6 AWG BARE, COPPER (ARRAY GROUNDING/BONDING) <br />WIRING GEN-10-AWG-THWN-2-CU-BLK FEET 1 10 AWG THWN-2, COPPER, BLACK (LINE 1) <br />WIRING GEN-10-AWG-THWN-2-CU-RD FEET 1 10 AWG THWN-2, COPPER, RED (LINE 2) <br />WIRING GEN-10-AWG-THWN-2-CU-BLK FEET 1 10 AWG THWN-2, COPPER, BLACK (LINE 1) <br />WIRING GEN-10-AWG-THWN-2-CU-RD FEET 1 10 AWG THWN-2, COPPER, RED (LINE 2) <br />WIRING GEN-10-AWG-THWN-2-CU-WH FEET 1 10 AWG THWN-2, COPPER, WHITE (NEUTRAL) <br />WIRING GEN-8-AWG-THWN-2-CU-GR FEET 1 8 AWG THWN-2, COPPER, GREEN (GROUND) <br />WIREWAY GEN-EMT-0_75DIA FEET 1 EMT CONDUIT, 0.75 DIA. <br />OCPD GENERIC MANUFACTURER GEN-CB-20A-240VAC PIECES 1 CIRCUIT BREAKER, 20A, 240VAC <br />OCPD GENERIC MANUFACTURER GEN-CB-20A-240VAC 1 PIECE 1 CIRCUIT BREAKER, 20A, 240VAC <br />OCPD GENERIC MANUFACTURER GEN-CB-15A-240VAC 1 PIECE 1 CIRCUIT BREAKER, 15A, 240VAC <br />TRANSITION BOX GENERIC GEN-AWB-TB-4-4X 1 PIECE 1 TRANSITION/PASS-THROUGH BOX, WITH 4 TERMINAL BLOCKS <br />AC DISCONNECT 1 PIECE 1 <br />1 <br />1 <br />I <br />3 <br />I <br />I <br />I <br />1 <br />4 <br />A <br />B <br />B <br />C <br />3 <br />5 <br />3 <br />2 <br />D <br />C D <br />C D <br />C D B <br />C D B <br />Q-CELLS Q.PEAK DUO BLK ML-G10+ 400 10 Q-CELLS Q.PEAK DUO BLK ML-G10+ 400, 132 CELLS, MONOCRYSTALLINE SILICON <br />ENPHASE IQ8PLUS-72-2-US (240V)10 ENPHASE IQ8PLUS-72-2-US (240V) MICRO INVERTER <br />10 <br />30 <br />EATON DG222URB EATON DG222URB, 2-POLE, NON-FUSED, 60A, 240VAC OR EQUIVALENT <br />50 <br />10 <br />10 <br />10 <br />60 <br />60 <br />50 <br />CS <br />L <br />B <br /> <br /># <br /> <br />1 <br />0 <br />4 <br />9 <br />1 <br />0 <br />8 <br />(8 <br />5 <br />5 <br />) <br />7 <br />7 <br />5 <br />- <br />8 <br />7 <br />7 <br />5 <br />CA <br />L <br />I <br />F <br />O <br />R <br />N <br />I <br />A <br /> <br />S <br />T <br />A <br />T <br />E <br />EN <br />E <br />R <br />G <br />Y <br /> <br />I <br />N <br />C <br />. <br />NA <br />M <br />E <br />: <br /> <br />I <br />R <br />M <br />A <br /> <br />G <br />O <br />N <br />Z <br />A <br />L <br />E <br />Z <br />AD <br />D <br />R <br />E <br />S <br />S <br /> <br />: <br /> <br />1 <br />9 <br />2 <br />7 <br /> <br />W <br /> <br />C <br />A <br />M <br />D <br />E <br />N <br /> <br />P <br />L <br />CI <br />T <br />Y <br /> <br />: <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />ST <br />A <br />T <br />E <br />, <br />Z <br />I <br />P <br /> <br />C <br />O <br />D <br />E <br />: <br /> <br />C <br />A <br />, <br />9 <br />2 <br />7 <br />0 <br />4 <br />AH <br />J <br /> <br />: <br /> <br />C <br />I <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />FI <br />N <br />A <br />N <br />C <br />E <br /> <br />T <br />Y <br />P <br />E <br />: <br /> <br />N <br />O <br />N <br />E <br />SO <br />L <br />A <br />R <br /> <br />P <br />E <br />R <br />M <br />I <br />T <br /> <br />P <br />A <br />C <br />K <br />A <br />G <br />E <br />4. <br />0 <br />0 <br />0 <br /> <br />k <br />W <br /> <br />D <br />C <br />2. <br />9 <br />0 <br />0 <br /> <br />k <br />W <br /> <br />A <br />C <br />PVE-3 <br />SHEET <br />AL <br />T <br />N <br />A <br /> <br />E <br />N <br />E <br />R <br />G <br />Y <br /> <br />S <br />E <br />R <br />V <br />I <br />C <br />E <br />S <br />21 <br />6 <br />8 <br /> <br />W <br /> <br />G <br />R <br />O <br />V <br />E <br /> <br />P <br />K <br />W <br />Y <br />AM <br />E <br />R <br />I <br />C <br />A <br />N <br /> <br />F <br />O <br />R <br />K <br />, <br /> <br />U <br />T <br />. <br />84 <br />0 <br />0 <br />3 <br /> <br />8 <br />0 <br />1 <br />- <br />7 <br />3 <br />5 <br />- <br />5 <br />1 <br />2 <br />3 <br />RE <br />V <br /> <br />D <br />E <br />S <br />C <br />R <br />I <br />P <br />T <br />I <br />O <br />N <br />DA <br />T <br />E <br /> <br />D <br />B <br /> <br />C <br />B <br />R <br />E <br /> <br />V <br /> <br />I <br /> <br />S <br /> <br />I <br /> <br />O <br /> <br />N <br /> <br />S <br />EN <br />E <br />R <br />G <br />Y <br /> <br /> S <br />E <br />R <br />V <br />I <br />C <br />E <br />S <br />DE <br />S <br />I <br />G <br />N <br />E <br />D <br /> <br />B <br />Y <br />: <br />IN <br />S <br />T <br />A <br />L <br />L <br />E <br />D <br /> <br />B <br />Y <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />I <br />N <br />F <br />O <br />R <br />M <br />A <br />T <br />I <br />O <br />N <br />PROJECT NO : CSD-0250 <br />DATE DRAWN: 8.23.2022 <br />DRAWN BY : HO SUET BILARAN <br />DATE CHECKED : 8.23.2022 <br />CHECKED BY : MARY GRACE RAMOS <br />1927 W Camden Pl <br />11/30/22