SCOPE OF WORK: <br />INSTALL (18) CANADIAN CS1Y-390MS SOLAR ELECTRIC MODULES AND <br />(18) SOLAREDGE P401 DC POWER OPTIMIZERS ON THE EXISTING 1ST STORY <br />COMPOSITION ROOF. INSTALL ASSOCIATED MOUNTING HARDWARE, <br />JUNCTION BOXES, CONDUIT, CONDUCTORS AND GROUNDING. INSTALL (1) <br />SOLAREDGE SE6000H-US INVERTER WITH INTEGRATED DC DISCONNECT, (1) <br />AC DISCONNECT, AND INSTALL OCPD IN MAIN SERVICE PANEL. UPGRADE <br />MAIN SERVICE PANEL TO 200 AMPS. <br />HOMEOWNER: JESUS CERVANTES <br />PH: 714.515.2269 <br />ADDRESS: 2013 W. 12TH STREET <br />SANTA ANA, CA 92703 <br />DATE: 5/4/22 <br />MAGIC SUN POWER INC <br />557 OLMSTED DRIVE <br />GLENDALE, CA 91202 <br />PH: 818.388.5478 EDVIN ARAKELIAN C10 - 999485 <br />VICINITY MAP <br />CERVANTES <br />RESIDENCE <br />SHEET INDEX: <br />SHEET 1 PROJECT INFO, VICINITY MAP, NOTES, SCOPE OF WORK <br />SHEET 2 SITE/ROOF PLAN, ELEVATION DETAIL <br />SHEET 3 ELECTRIC LINE DRAWING, GROUNDING DETAIL <br />SHEET 4 CALCULATIONS, SIGNS <br />ATTACHED MODULE, INVERTER, MOUNTING HARDWARE SPEC SHEETS, <br />STRUCTURAL REPORT <br />NTS <br />SHEET <br />NOTICE: <br />ANY CHANGES TO OR USES OF THESE DOCUMENTS/DRAWINGS WITHOUT THE <br />WRITTEN CONSENT OF JENNIFER KEMME OR SCOTT HARRIS ARE STRICTLY PROHIBITED. <br />1 OF 4 <br />PLANS PREPARED BY: <br />JENNIFER KEMME <br />PH: 909.748.1300 <br />(18) CANADIAN CS1Y-390MS <br />PEAK POWER = 390 W <br />MAX OPERATING CURRENT = 9.05 A <br />MAX OPERATING VOLTAGE = 43.10 V <br />OPEN CIRCUIT VOLTAGE = 51.90 V <br />SHORT CIRCUIT CURRENT = 9.82 A <br />MAX SERIES FUSE RATING = 16 A <br />TEMP. COEFF. OF Voc = -0.28%/°C <br />DIMENSIONS = 79.6" X 39.2" X 1.4" <br />WEIGHT = 52.9 LBS <br />GENERAL NOTES: <br />1. THIS SYSTEM COMPLIES WITH THE 2019 CRC, 2019 CBC, 2019 CFC, AND THE 2019 <br />CEC. <br />2. THE SYSTEM WILL NOT BE TURNED-ON UNTIL THE SERVING UTILITY COMPANY <br />HAS BEEN NOTIFIED. <br />3. THE INSTALLED SOLAR SYSTEM HAS A DISTRIBUTED WEIGHT LESS THAN 4 PSF. <br />4. THE CONCENTRATED LOAD FOR EACH VERTICAL SUPPORT IS LESS THAN 40 LBS. <br />5. ALL PV EQUIPMENT IS LISTED BY A RECOGNIZED TESTING LAB. INVERTERS ARE <br />UL 1741 COMPLIANT. <br />6. THE BACKFED BREAKER WILL BE LOCATED AT THE OPPOSITE END OF THE BUS <br />FROM THE MAIN BREAKER. <br />7. CONDUCTORS ARE 90° C RATED COPPER WIRE. <br />8. ANY CONDUCTORS EXPOSED TO SUNLIGHT ARE LISTED AS SUNLIGHT <br />RESISTANT. <br />9. IF DC CONDUCTORS ARE RUN INSIDE THE BUILDING, THEY WILL BE CONTAINED <br />IN A METAL RACEWAY. <br />10. ANY CONDUCTORS BETWEEN SEPARATE ARRAYS ON THE ROOF WILL BE <br />PROTECTED IN CONDUIT. <br />11. THE EQUIPMENT GROUNDING CONDUCTOR ON THE ROOF WILL BE PROTECTED <br />FROM PHYSICAL DAMAGE. IT WILL BE TUCKED NEATLY UNDER THE MODULES <br />AND RAILS AND SECURED IN PLACE. <br />12. THE MODULES WILL BE ATTACHED TO THE EQUIPMENT GROUNDING <br />CONDUCTOR IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. <br />13. ALL EXTERIOR CONDUIT, FITTINGS AND BOXES ARE RAIN-TIGHT AND APPROVED <br />FOR USE IN WET LOCATIONS. <br />14. CLEARANCES AROUND ALL ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN <br />ACCORDANCE WITH CEC 110.26. <br />15. SOLAR MODULES WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL OR <br />BUILDING ROOF VENTS. <br />16. IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE <br />GROUNDING ELECTRODE SYSTEM, A GROUNDING ELECTRODE SYSTEM WILL BE <br />INSTALLED PER CEC 250.50.THE ELECTRICAL SERVICE WILL BE BONDED TO THE <br />WATER AND GAS PIPING PER SECTION 250.104 OF THE CEC. <br />17. A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH CAL-OSHA <br />REGULATIONS. <br />79119PV <br />INVERTER/DC DISCONNECT: (1) SOLAREDGE SE6000H-US <br />MAX DC INPUT VOLTAGE = 480 V <br />NOMINAL DC INPUT VOLTAGE = 380 V <br />MAX DC INPUT CURRENT = 16.5 A <br />DC DISCONNECT MAX INPUT CURRENT = 30.0 A <br />NUMBER OF DC INPUTS = 2 <br />RATED AC POWER = 6000 W <br />AC VOLTAGE = 240 V <br />MAX AC OUTPUT CURRENT = 25.0 A <br />NEMA 4X ENCLOSURE <br />DIMENSIONS = 17.7" X 14.6" X 6.8" <br />WEIGHT = 30.2 LBS <br />PHOTOVOLTAIC SOLAR PROJECT INFORMATION: <br />SYSTEM SIZE: 7.020 kW (DC) <br />MODULES: <br />ARRAY: INSTALLED WEIGHT = 3.0 PSF <br />ROOF COVERAGE = 390 SF, <br />ARRAYS COVER 22% OF TOTAL ROOF AREA <br />MOUNTING HARDWARE: UNIRAC SOLARMOUNT RAIL <br />UNIRAC FLASHKIT PRO ATTACHMENTS <br />5 16" STAINLESS STEEL LAG BOLTS @ <br />72" OC OR LESS WITH A MINIMUM OF <br />21 2" PENETRATION INTO ROOF RAFTERS <br />EXISTING ROOF INFO: 1 STORY, COMPOSITION SHINGLE <br />2 X 4 RAFTERS @ 24" OC <br />MODULE ADD-ON: (18) SOLAREDGE P401 <br /> DC POWER OPTIMIZERS <br /> MAX DC INPUT VOLTAGE = 60 V <br /> OPERATING VOLTAGE RANGE = 8 V - 60 V <br /> MAX DC INPUT CURRENT = 11.75 A <br /> MAX DC OUTPUT CURRENT = 15 A <br /> DC OUTPUT VOLTAGE = 380 V <br /> MAX POWER PER STRING <br />(CONTROLLED BY INVERTER) = 5700 W <br /> NEMA 6P ENCLOSURE <br /> DIMENSIONS = 5.1" X 6.0" X 1.2" <br /> WEIGHT = 1.5 LB <br />Bldg# 101111068 <br />Elec# 20176694 <br />Issued 07/21/22 <br />2013 W. 12th St. <br />07/27/22