PROJECT SITE <br />OWNER:CHAD BARKER <br />ADDRESS:2014 NORTH FLOWER ST <br />SANTA ANA, CA 92706 <br />APN:39905105 <br />UTILITY:SCE <br />AHJ:ORANGE COUNTY <br />CONSTRUCTION TYPE: VB <br />OCCUPANCY TYPE: R3 <br />ELEVATION: 138 FT ABOVE SEA LEVEL <br />PROJECT INFO <br />VICINITY MAP <br />A0 <br />SOLAR PHOTOVOLTAIC SYSTEM NOTES <br />1. ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A RECOGNIZED TESTING LABORATORY AND INSTALLED PER THE LISTING <br /> REQUIREMENTS AND THE MANUFACTURER'S INSTRUCTIONS, CEC 110.2, 110.3, 690.4(B) AND 690.12(D). <br />2. ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES. <br />3. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH CEC ARTICLE 250. <br />4. ALL PV CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALL HAVE PROTECTION AGAINST OVERCURRENT PER CEC 690.9. <br />5. DISCONNECTING MEANS OF THE PV SYSTEM (INCLUDING RAPID SHUTDOWN INITIATION) SHALL BE LOCATED IN READILY <br /> ACCESSIBLE LOCATION NEAR THE EQUIPMENT, CEC 690.13, 690.15. <br />6. ENERGY STORAGE SYSTEMS TERMINALS LOCATED MORE THAN 5 FEET AWAY OR ON OPPOSITE SIDE OF WALL FROM CONNECTED <br /> EQUIPMENT MUST HAVE DISCONNECTING MEANS IN ACCORDANCE WITH CEC 706.7(E) AND LABELED PER 706.7(D). A SECOND <br /> DISCONNECTING MEANS LOCATED AT THE CONNECTED EQUIPMENT SHALL BE INSTALLED WHERE THE DISCONNECTING MEANS AT <br /> THE ESS END OF THE CIRCUIT IS NOT WITHIN SIGHT. <br />7. RAPID SHUTDOWN EQUIPMENT TO COMPLY WITH CEC 690.12. <br />8. THE UTILITY-INTERACTIVE INVERTERS SHALL AUTOMATICALLY DE-ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL <br /> PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THE SYSTEM AND SHALL REMAIN IN THAT STATE UNTIL THE <br /> ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED, CEC 705.40. <br />9. ALL CONDUCTORS IN EXPOSED OUTDOOR LOCATIONS SHALL BE LISTED AND IDENTIFIED FOR USE IN DIRECT SUNLIGHT AND FOR <br /> THE APPLICATION. CEC310.10(D) AND 690.31(C) THROUGH (F). <br />10. INSULATION OF EXPOSED CONDUCTORS UNDER THE MODULES SHALL BE USE-2 OR PV-WIRE TYPE FOR PV SYSTEMS, CEC 690.31(C). <br />11. FINE-STRANDED CABLE CONNECTIONS MUST BE MADE IN LUGS AND TERMINALS LISTED AND MARKED FOR THE USE, CEC 110.14. <br />12. ALL PV CIRCUIT CONDUCTORS SHALL BE MARKED ON EACH END AND GROUPED FOR UNIQUE IDENTIFICATION, CEC 690.31(B). <br />13. ALL GROUNDED, (NEUTRAL), CONDUCTORS' INSULATION SHALL BE SOLID WHITE, GRAY, OR WITH 3-WHITE STRIPES, CEC 200.6, <br /> 200.7, & 400.22; AND ALL GROUNDING CONDUCTORS SHALL BE OF BARE WIRE WITHOUT COVERING, OR WITH INSULATION OF <br /> GREEN OR GREEN WITH YELLOW STRIPES, CEC 250.119 & 400.23. THE COLOR OF UNGROUNDED CONDUCTORS SHALL BE OTHER <br /> THAN FOR GROUNDED, (NEUTRAL), AND GROUNDING CONDUCTORS, CEC 310.110(C). <br />14. MAXIMUM CONDUCTOR LENGTH BETWEEN SUPPLY SIDE CONNECTION AND OVERCURRENT PROTECTION IS 10 FEET, CEC 705.31. <br />15. CONNECTIONS ON THE LOAD SIDE OF THE SERVICE DISCONNECTING MEANS OF THE OTHER SOURCE(S) AT ANY DISTRIBUTION <br /> EQUIPMENT ON THE PREMISES SHALL MEET THE FOLLOWING, CEC 705.12(B). <br />16. DC WIRING INSIDE A BUILDING MUST BE IN METALLIC TYPE RACEWAYS, CONDUITS, ENCLOSURES, OR CABLE SHEATHINGS, CEC <br /> 690.31(G). <br />17. METALLIC TYPE RACEWAYS, CONDUITS, ENCLOSURES, AND CABLE SHEATHS CONTAINING CIRCUITS OVER 250-VOLTS TO GROUND <br /> MUST BE BONDED IN ACCORDANCE WITH CEC 250.97. <br />18. ALL EXTERIOR CONDUIT, FITTINGS AND BOXES SHALL BE RAIN TIGHT AND APPROVED FOR USE IN WET LOCATIONS, CEC 314.15 <br />19. FLEXIBLE, FINE-STRANDED CABLES SHALL BE TERMINATED ONLY WITH TERMINALS, LUGS, DEVICES OR CONNECTOR THAT ARE <br /> IDENTIFIED AND LISTED FOR SUCH USE, CEC 690.31(H) & 110.14. <br />20. CONNECTORS SHALL BE OF LATCHING OR LOCKING TYPE. CONNECTORS THAT ARE READILY ACCESSIBLE AND OPERATING AT <br /> OVER 30 VOLTS SHALL REQUIRE TOOL TO OPEN AND MARKED “DO NOT DISCONNECT UNDER LOAD” OR “NOT FOR CURRENT <br /> INTERRUPTING”, CEC 690.33(C) & (E)(2). <br />21. EQUIPMENT GROUNDING CONDUCTOR FOR PV MODULES SMALLER THAN 6 AWG SHALL BE PROTECTED FROM PHYSICAL DAMAGE <br /> BY A RACEWAY OR CABLE ARMOR, CEC 690.46 & 250.120(C). <br />22. THE INTERCONNECTION POINT SHALL BE ON THE SUPPLY SIDE OF ALL GROUND-FAULT PROTECTION EQUIPMENT, CEC 705.32. <br />23. CABLES/WIRES THAT ARE SUBJECT TO PHYSICAL DAMAGE, SUCH AS THOSE NOT LOCATED UNDER THE MODULES, MUST BE <br /> PROTECTED, CEC 300.4. <br />24. PROPOSED LOCATIONS OF ELECTRICAL SERVICE REPLACEMENTS MUST ALSO BE APPROVED BY THE ELECTRICAL UTILITY <br /> COMPANY. <br />25. FOR ELECTRICAL SERVICE REPLACEMENTS, BONDING TO THE METAL PIPES OF NATURAL GAS, HOT WATER, AND COLD WATER MUST <br /> BE PROVIDE, CEC 250.104. <br />26. GROUNDING ROD ELECTRODES SHALL BE MINIMUM 5/8’’ IN DIAMETER AND INSTALLED 8’ MINIMUM IN CONTACT WITH <br /> SOIL, CEC 250.52(A)(5), 250.53(G). <br />27. MINIMUM 7/8’’ CLEARANCE FROM ROOF TO BOTTOM OF CONDUIT OR USE A TEMPERATURE ADDER OF 33 DEGREES C. <br /> CEC 310.15(B)(3)(C) <br />28. EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST OUTLETS, & VENTILATIONS INTAKE AIR OPENINGS SHALL NOT BE COVERED OR <br /> BLOCKED BY THE SOLAR PHOTOVOLTAIC SYSTEM. <br />29. EXISTING DWV PLUMBING VENT TERMINATIONS THAT ARE HORIZONTALLY LOCATED CLOSER THAN 12" FROM THE PROPOSED <br /> MODULES, MUST BE REROUTED, OR MUST BE EXTENDED A MINIMUM OF 6" ABOVE THE SURFACE OF THE MODULES, CPC 906.1. <br />30. EXISTING B-VENT TERMINATIONS, FOR FUEL BURNING APPLIANCES, WHERE ADJACENT TO THE PROPOSED MODULES, MUST BE <br /> EXTENDED 12" ABOVE THE MODULES' TOP SURFACE, CMC 802.6.1(1) & CPC 509.6.1(1). <br />31. THE MARKINGS, "WARNING: PHOTOVOLTAIC POWER SOURCE", FOR DC RACEWAYS AND CABLE ASSEMBLIES MUST BE AT 10' O.C.; <br /> AND BENDS, ABOVE OR BELOW PENETRATIONS OF ROOFS, CEILINGS, WALLS, OR BARRIERS, CEC 690.31(G)(4). <br />32. PV COMBINER PANELBOARDS MUST HAVE PERMANENT MARKINGS INDICATING THAT THEY ARE DEDICATED FOR PV CIRCUITS ONLY <br /> NO LOADS ARE TO BE CONNECTED. <br />33. WORKING CLEARANCES TO BE PROVIDED AT NEW AND EXISTING ELECTRICAL EQUIPMENT, CEC 110.26. <br />34. A LADDER MUST BE PROVIDED FOR INSPECTIONS IN ACCORDANCE WITH CAL-OSHA REGULATIONS, SECURED AND EXTENDING 3' <br /> ABOVE THE ROOF. <br />35. ALL OF THE REQUIRED MARKINGS, SIGNS, AND LABELS MUST BE INSTALLED ON ALL EQUIPMENT PRIOR TO ANY INSPECTIONS. <br />36. LABELS SHALL BE REFLECTIVE, AND ALL LETTERS SHALL BE CAPITALIZED AND SHALL BE A MINIMUM HEIGHT OF 3/8'' IN WHITE ON A <br /> RED BACKGROUND. CEC 690.31(G)(4) <br />37. IDENTIFICATION OF POWER SOURCE RAPID SHUTDOWN AND LABELING SHALL BE IN ACCORDANCE WITH CEC 690.56(C). <br />38. WHEN THE MAIN CIRCUIT BREAKER IS DERATED, A PERMANENT MARKING MUST BE PROVIDED ON THE PANELBOARD TO INDICATE <br /> THAT THE MAIN CIRCUIT BREAKER HAS BEEN DOWNSIZED TO _______ AMPS, DO NOT UPSIZE IT. <br />39. PANELS AND MODULES NOT TO BE INSTALLED ON ROOF BELOW AN EMERGENCY ESCAPE AND RESCUE OPENING. CRC R324.6.2.2 <br />40. GROUND-MOUNTED PV SYSTEMS MUST HAVE A CLEAR, BRUSH-FREE AREA OF 10-FEET AND A FIRE SEPARATION DISTANCE OF 5-FEET <br /> MINIMUM TO OTHER STRUCTURES AND PROPERTY LINES, CRC R324.7 & R302.1. <br />41. PLAN CHECK AND PERMIT FOR PV SYSTEM AND ASSOCIATED EQUIPMENT ONLY. <br />42. ALL PROJECTS SUBJECT TO FIELD VERIFICATION FOR CODE COMPLIANCE. <br />43. APPROVED SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED WITHIN THE DWELLING UNIT AND SHALL BE FIELD <br /> VERIFIED EITHER THROUGH FINAL BUILDING INSPECTION. SMOKE ALARMS ARE REQUIRED TO BE INSTALLED IN ALL <br /> BEDROOMS, OUTSIDE EACH BEDROOM, AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. CARBON MONOXIDE ALARMS <br /> ARE REQUIRED OUTSIDE EACH BEDROOM AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. R314.1, R315.1 <br />44. ROOF ACCESS POINTS. ROOF ACCESS POINTS SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF <br /> GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING <br /> CONSTRUCTION IN LOCATIONS WHERE THE ACCESS DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS <br /> TREE LIMBS, WIRES OR SIGNS (R331.4.1).LADDERS SHALL BE OSHA APPROVED AND SECURED TO THE STRUCTURE FOR <br /> INSPECTION PURPOSES.CONTRACTORS ARE REQUIRED TO BE PRESENT FOR THE FIRST AND/OR FINAL INSPECTIONS. <br />45. NOTIFY SERVING UTILITY BEFORE ACTIVATION OF PV SYSTEM. <br />8.075 DC KW SOLAR PV AC MODULE SYSTEM- ROOF MOUNT <br />BARKER RESIDENCE <br />2014 NORTH FLOWER ST, SANTA ANA, CA 92706 <br />APPLICABLE CODES <br />ALL MATERIALS, EQUIPMENT, INSTALLATION AND WORK SHALL <br />COMPLY WITH THE FOLLOWING APPLICABLE CODES <br />2019 CA BUILDING CODES (CBC) <br />2019 CA RESIDENTIAL CODES (CRC) <br />2019 CA MECHANICAL CODES (CMC) <br />2019 CA PLUMBING CODES (CPC) <br />2019 CA FIRE CODES (CFC) <br />2019 CA ELECTRICAL CODES (CEC) <br />2019 CA ENERGY CODES (CEnC) <br />2019 CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGreen) <br />PROJECT SITE <br />VICINITY MAP <br />AERIAL VIEW <br />OWNER <br />PROJECT TITLE <br />JOBSITE ADDRESS <br />SHEET TITLE <br />SHEET NUMBER <br />CONTRACTOR <br />15013 CALIFA STREET, <br />VAN NUYS, CA 91411 <br />818-670-7769 <br />WWW.PLUGITINSOLAR.COM <br />C-10 License # 986882 <br />CHAD <br />BARKER <br /> 8.075 DC kW <br />AC MODULE <br />SYSTEM <br />7.296 kW CEC-AC RATING <br />2014 <br />NORTH FLOWER ST <br />SANTA ANA <br />CA 92706 <br />DESIGN BY: NT <br />NATALIA@PLUGITINSOLAR.COM <br />DATE <br />DRAWN <br />DESIGN <br />REVISION <br />DATE DESCRIPTION <br />REVISION <br />SIGNATURE OF LICENSE HOLDER <br />4-2-22 <br />PROJECT SCOPE <br />INSTALLATION OF ROOF MOUNT SOLAR PV SYSTEM <br />NEW <br />EQUIPMENT:19 SPR-M425-H-AC <br />SUNPOWER AC MODULES <br />19 SPR-M425-H-AC (240V) [Sl1] <br />SUNPOWER INVERTERS <br />SYSTEM SIZE: 8.075 DC kW RATING <br />7.296 CEC AC RATING <br />SERVICE: EXISTING 200A MAIN SERVICE PANEL <br />ARRAY AREA: 20.78 SQFT X 19 = 394.82 SQFT <br />SHEET INDEX <br />A0 PROJECT INFO, VICINITY MAP, NOTES <br />A1 SITE PLAN <br />A2 MOUNTING PLAN <br />A3 MOUNTING DETAILS <br />E1 SINGLE LINE DIAGRAM <br />E2 ELECTRICAL CALCULATIONS <br />E3 REQUIRED SIGNAGE <br />E4 AC MODULE DATA SHEET <br />S1 MOUNTING DATA SHEET <br />S2 RACKING DATA SHEET <br />S3 RACKING GROUNDING <br />S4 RACKING CERTIFICATION <br />www. Loyd W Martin .com <br />Solar Structures Engineering <br />#2022-3209 Structural Only August 09, 2022 <br />Exp. 3-31-19 <br />No. C58724 <br />NITRAMW.DYO <br />REGISTEREDPROFESSIONALENGINEER <br />C <br />V <br />L <br />FOETATS <br />ALIFORNIAICIL <br />123 <br />***HISTORIC PROPERTY*** <br />Bldg #101111890 <br />Elect #20177292 <br />Permits issued on 9/12/22 <br />Plng ok per P. Gomez <br />2014 N Flower St <br />09/12/22