Laserfiche WebLink
2030 N Tustin Ave. <br />16.0 kW DC SOLAR PHOTOVOLTAIC SYSTEM <br />2030 N Tustin Ave., Santa Ana, CA 92705 <br />JPH <br />G-1 <br />SHEET NUMBER: <br />DRAWN BY: <br />DATE: <br />REV: <br />5/24/22 <br />5/27/22 <br />PROJECT: <br />2030 N TUSTIN AVE. <br />2030 N TUSTIN AVE., <br />SANTA ANA, CA 92705 <br />LICENSE HOLDER'S <br />SIGNATURE <br />CONTRACTOR: <br />SUNKO SOLAR <br />1540 6TH ST. #304 <br />SANTA MONICA, CA 90401 <br />(415) 866-0676 <br />CSLB # 1021907 <br /> C-46 <br />SCOPE OF WORK SHEET INDEX <br />PARCEL MAP <br />NTS <br />VICINITY MAP <br />NTS <br />AERIAL MAP <br />NTS <br />SIGNAGE <br />INSTALLATION OF: <br />(40) HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ 400 MODULES & <br />(40) ENPHASE IQ7PLUS-72-2-US (208V) MICROINVERTER(S) <br />STC RATING: 16.0 KW DC <br />CEC RATING: 14.34 KW AC <br />OCCUPANCY TYPE: B <br />CONSTRUCTION TYPE: V-B <br />AHJ: CITY OF SANTA ANA <br />APN: 396-332-08 <br />G-1 SCOPE OF WORK; SHEET INDEX; VICINITY MAP; NOTES; SIGNAGE <br />G-2 PROPERTY PLAN <br />G-3 ROOF PLAN; EQUIPMENT LOCATIONS <br />S-1 ROOF FRAMING PLAN; ELEVATIONS; STRUCTURAL DETAILS; BRANCH CIRCUIT CONFIGURATION <br />E-1 ELECTRICAL LINE DIAGRAM; ELECTRICAL CALCULATIONS <br />Z-1 SPECIFICATIONS - MODULE, PV INVERTER, ELECTRICAL EQUIPMENT <br />Z-2 SPECIFICATIONS - RACKING <br />Z-3 SPECIFICATIONS - GROUNDING & BONDING <br />ALL MATERIALS, EQUIPMENT, INSTALLATION AND WORK SHALL COMPLY WITH THE FOLLOWING APPLICABLE CODES: <br />x 201 9 CBC / 201 8 IBC <br />x 201 9 CRC / 201 8 IRC <br />x 201 9 CEC / 201 7 NEC <br />x 201 9 CMC / 201 8 UMC <br />x 201 9 CPC / 201 8 UPC <br />x 201 9 CFC / 201 8 IFC <br />x 201 9 BUILDING ENERGY EFFICIENCY STANDARDS <br />x 201 9 CALIFORNIA ENERGY CODE TITLE 24 <br />x 201 9 CALIFORNIA HEALTH AND SAFETY CODE <br />x CEC ARTICLE 690 <br />x CFC ARTICLE 605.11 <br />x IEEE STANDARD 929 <br />x UL STANDARD 1741 <br />x OSHA 29 CFR 1910.269 <br />x WHERE APPLICABLE, RULES OF THE PUBLIC UTILITIES COMMISSION REGARDING SAFETY AND RELIABILITY <br />x THE AUTHORITY HAVING JURISDICTION <br />x MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS <br />GOVERNING CODES <br />NOTES <br />GENERAL <br />1. UTILITY SHALL BE NOTIFIED BEFORE ACTIVATION OF PV SYSTEM. <br />2. 110.2 APPROVAL: ALL ELECTRICAL EQUIPMENT SHALL BE LABELED, <br />LISTED, OR CERTIFIED BY A NATIONALLY RECOGNIZED TESTING <br />LABORATORY ACCREDITED BY THE UNITED STATES OCCUPATIONAL <br />SAFETY HEALTH ADMINISTRATION. <br />3. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO <br />INITIATING CONSTRUCTION. <br />4. CONTRACTOR SHALL REVIEW ALL MANUFACTURER INSTALLATION <br />DOCUMENTS PRIOR TO INITIATING CONSTRUCTION. <br />5. ALL EQUIPMENT AND ASSOCIATED CONNECTIONS OF INVERTERS, <br />MODULES, PV SOURCE CIRCUITS, BATTERY CONNECTIONS, ETC. AND <br />ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL BE <br />INSTALLED ONLY BY QUALIFIED PERSONNEL (CEC 690.4(E)). <br />6. THE CONTRACTOR OR OWNER MUST PROVIDE ROOF ACCESS <br />(LADDER TO ROOF) FOR THE ALL REQUIRED INSPECTIONS. LADDERS <br />MUST BE OSHA APPROVED, MINIMUM TYPE I WITH A 250 LB RATING, <br />IN GOOD CONDITION AND DESIGNED FOR ITS INTENDED USE. <br />7. CONTRACTOR SHALL VERIFY THAT THE ROOF STRUCTURE WILL <br />WITHSTAND THE ADDITIONAL LOADS. <br />8. LAG SCREWS SHALL PENETRATE A MINIMUM 2" INTO SOLID SAWN <br />STRUCTURAL MEMBERS AND SHALL NOT EXCEED MANUFACTURER <br />RECOMMENDATIONS FOR FASTENERS INTO ENGINEERED <br />STRUCTURAL MEMBERS. <br />9. AN ACCESS POINT SHALL BE PROVIDED THAT DOES NOT PLACE THE <br />GROUND LADDER OVER OPENINGS SUCH AS WINDOWS OR DOORS <br />ARE LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION AND <br />IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH <br />OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES, OR SIGNS. <br />(CRC R331.4.2) <br />10. WHERE DC CONDUCTORS ARE RUN INSIDE BUILDING, THEY SHALL BE <br />CONTAINED IN A METAL RACEWAY; THEY SHALL NOT BE INSTALLED <br />WITHIN 10" OF THE ROOF DECKING OR SHEATHING EXCEPT WHERE <br />COVERED BY THE PV MODULES AND EQUIPMENT. (CEC 690.31(E)(1)) <br />11. PLUMBING AND MECHANICAL VENTS THROUGH THE ROOF SHALL <br />NOT BE COVERED BY SOLAR MODULES - NO BUILDING, PLUMBING, OR <br />MECHANICAL VENTS TO BE COVERED, OBSTRUCTED OR ROUTED <br />AROUND SOLAR MODULES. <br />12. ALL FIELD-INSTALLED JUNCTION, PULL, AND OUTLET BOXES LOCATED <br />BEHIND MODULES SHALL BE ACCESSIBLE DIRECTLY OR BY <br />DISPLACEMENT OF A MODULE SECURED BY REMOVABLE FASTENERS. <br />ELECTRICAL <br />1. WIRING MATERIALS SHALL COMPLY WITH MAXIMUM CONTINUOUS <br />CURRENT OUTPUT AT 25°C AND MAXIMUM VOLTAGE AT 600V; WIRE <br />SHALL BE WET RATED AT 90°C. <br />2. EXPOSED PHOTOVOLTAIC SYSTEM CONDUCTORS ON THE ROOF WILL <br />BE USE-2 OR PV TYPE WIRE. <br />3. PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTIFIED AND <br />GROUPED. THE MEANS OF IDENTIFICATION SHALL BE PERMITTED BY <br />SEPARATE COLOR-CODING, MARKING TAPE, TAGGING OR OTHER <br />APPROVED MEANS <br />4. ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE RAIN-TIGHT <br />AND APPROVED FOR USE IN WET LOCATIONS. (CEC 314.15) <br />5. WHERE CONDUCTORS ARE INSTALLED UNDERGROUND, SECTION <br />300.5 OF THE CEC MUST BE FOLLOWED TO ENSURE PROPER <br />PROTECTION. <br />6. ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND <br />ELECTRICALLY CONTINUOUS. (CEC 250.90, 250.96) <br />7. WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE <br />NOT SPECIFIED, CONTRACTOR SHALL SIZE THEM ACCORDING TO <br />APPLICABLE CODES. <br />8. FOR GROUNDED SYSTEMS, THE PHOTOVOLTAIC SOURCE AND <br />OUTPUT CIRCUITS SHALL BE PROVIDED WITH A GROUND-FAULT <br />PROTECTION DEVICE OR SYSTEM THAT DETECTS A GROUND FAULT, <br />INDICATES THAT FAULT HAS OCCURED, AND AUTOMATICALLY <br />DISCONNECTS ALL CONDUCTORS OR CAUSES THE INVERTER TO <br />AUTOMATICALLY CEASE SUPPLYING POWER TO OUTPUT CIRCUITS. <br />(CEC 690.35(C)) <br />9. FOR UNGROUNDED SYSTEMS, THE INVERTER IS EQUIPPED WITH <br />GROUND FAULT PROTECTION AND A GFI FUSE PORT FOR GROUND <br />FAULT INDICATION. <br />10. PV MODULE FRAMES SHALL BE BONDED TO RACKING RAIL OR BARE <br />COPPER GEC/EGC PER THE MODULE MANUFACTURER'S LISTED <br />INSTRUCTION SHEET. <br />11. PV MODULE RACKING RAIL SHALL BE BONDED TO BARE COPPER <br />G.E.C. VIA WEEB LUG, ILSCO GBL-4DBT LAY-IN LUG, OR EQUIVALENT <br />LISTED LUG. <br />12. THE PHOTOVOLTAIC INVERTER WILL BE LISTED AS UL 1741 <br />COMPLIANT. <br />13. RACKING AND BONDING SYSTEM TO BE UL2703 RATED. <br />14. ANY REQUIRED GROUNDING ELECTRODE CONDUCTOR WILL BE <br />CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN <br />LISTED EQUIPMENT. (CEC 250.64(C)) <br />15. WHEN BACKFED BREAKER IS THE METHOD OF UTILITY <br />INTERCONNECTION, THE BREAKERS SHALL NOT READ "LINE AND <br />LOAD". <br />16. WHEN APPLYING THE 120% RULE OF CEC 705.12(D)(2), THE SOLAR <br />BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE BUS <br />FROM THE MAIN BREAKER PER 705.12(D)(7). <br />17. THE WORKING CLEARANCE AROUND THE EXISTING ELECTRICAL <br />EQUIPMENT AS WELL AS THE NEW ELECTRICAL EQUIPMENT WILL BE <br />MAINTAINED IN ACCORDANCE WITH CEC 110.26(A) <br />18. RAPID SHUTDOWN REQUIREMENTS: PV SYSTEMS INSTALLED ON OR <br />IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION. PV <br />SYSTEM CONDUCTORS OF MORE THAN 3 FT INSIDE A BUILDING, OR <br />MORE THAN 1 FT FROM A PV ARRAY, SHALL BE LIMITED TO NOT <br />MORE THAN 30 VOLTS AND 240 VA WITHIN 30 SECONDS OF RAPID <br />SHUTDOWN INITIATION, IN ACCORDANCE WITH CEC 690.12(A)-(D) <br />TO BE PLACED JUNCTION BOXES, DISCONNECTS, RACEWAYS, <br />ENCLOSURES AND CABLE ASSEMBLIES; MARKING SHALL BE PLACED <br />ON INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES <br />AND CABLE ASSEMBLIES EVERY 10 FEET, WITHIN 1 FOOT OF TURNS <br />OR BENDS AND WITHIN 1 FOOT ABOVE AND BELOW PENETRATIONS <br />OF ROOF/CEILING ASSEMBLIES, WALLS OR BARRIERS: <br />WARNING: PHOTOVOLTAIC POWER SOURCE <br />PV SOLAR - AC DISCONNECT <br />PV SYSTEM DC DISCONNECT <br />RATED MAX POWER-POINT CURRENT - 10.8 A <br />RATED POWER-POINT VOLTAGE - 37.1 V <br />MAXIMUM SYSTEM VOLTAGE - 51.6 V <br />SHORT CIRCUIT CURRENT - 13.9 A <br />WARNING: ELECTRIC SHOCK HAZARD <br />TERMINALS ON BOTH THE LINE AND THE LOAD <br />SIDES MAY BE ENERGIZED IN THE OPEN POSITION <br />CAUTION <br />POWER TO THIS BUILDING IS ALSO SUPPLIED <br />FROM THE FOLLOWING SOURCES WITH <br />DISCONNECTS LOCATED AS SHOWN: <br />2030 N TUSTIN AVE., <br />SANTA ANA, CA 92705 <br />PV SOLAR <br />ARRAY <br />M <br />CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED <br />WARNING DUAL POWER SOURCES <br />SECOND SOURCE IS PHOTOVOLTAIC SYSTEM <br />RATED AC OUTPUT CURRENT: 32.2 A <br />NORMAL OPERATING AC VOLTAGE: 208 V <br />WARNING: THIS SERVICE METER IS ALSO SERVED <br />BY A PHOTOVOLTAIC SYSTEM <br />A <br />TO BE INSTALLED AT THE MAIN ELECTRICAL SERVICE: <br />TO BE INSTALLED AT THE MAIN SERVICE PANEL, <br />AC DISCONNECT, AND PV LOAD CENTER: <br />TO BE INSTALLED AT THE MAIN ELECTRICAL SERVICE AND SUBPANELS: <br />B <br />C <br />TO BE INSTALLED AT THE MAIN ELECTRICAL SERVICE: <br />WARNING: ELECTRIC SHOCK HAZARD <br />IF A GROUND FAULT IS INDICATED, <br />NORMALLY GROUNDED CONDUCTORS MAY BE <br />UNGROUNDED AND ENERGIZED <br />TO BE INSTALLED ON THE INVERTER (GROUNDED SYSTEMS): <br />E <br />TO BE INSTALLED ON THE DC DISCONNECT: <br />F <br />TO BE INSTALLED AT THE DC DISCONNECT: <br />TO BE INSTALLED AT THE AC DISCONNECT: <br />PHOTOVOLTAIC DISCONNECT FOR UTILITY OPERATIONS <br />TO BE INSTALLED AT THE AC DISCONNECT: <br />WARNING: ELECTRIC SHOCK HAZARD. THE DC <br />CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM <br />ARE UNGROUNDED AND MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />TO BE INSTALLED AT THE JUNCTION BOXES AND DC DISCONNECT <br />(UNGROUNDED SYSTEMS): <br />PV LOADS ONLY - DO NOT ADD <br />ADDITIONAL LOADS <br />TO BE INSTALLED AT THE DEDICATED PV LOAD CENTER: <br />G <br />H <br />I <br />J <br />K <br />L <br />PV ARRAY JUNCTION BOX PV LOAD CENTER <br />(WHEN PRESENT) <br />AC DISCONNECT <br />(WHEN PRESENT) <br />MAIN SERVICE <br />PANEL <br />A <br />H <br />D <br />J <br />K <br />B B <br />C <br />M <br />SUBPANEL <br />(WHEN PRESENT) <br />B <br />C <br />D <br />B <br />L <br />D <br />N <br />NI <br />O <br />N <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE "OFF" <br />POSITION TO <br />SHUTDOWN PV SYSTEM <br />AND REDUCE SHOCK <br />HAZARD IN ARRAY <br />SOLAR ELECTRIC <br />PV PANELS <br />RAPID SHUTDOWN SWITCH <br />FOR SOLAR PV SYSTEM <br />TO BE PLACED AT THE RAPID SHUTDOWN/DISCONNECT: <br />THE TITLE “SOLAR PV SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN” SHALL UTILIZE <br />CAPITALIZED CHARACTERS WITH A MINIMUM HEIGHT OF 9.5 MM (3∕M8 IN.) IN BLACK ON YELLOW <br />BACKGROUND, AND THE REMAINING CHARACTERS SHALL BE CAPITALIZED WITH A MINIMUM <br />HEIGHT OF 4.8 MM (3∕M16 IN.) IN BLACK ON WHITE BACKGROUND <br />TO BE INSTALLED AT THE MAIN ELECTRICAL SERVICE: <br />O <br />SIGNAGE FORMAT: ALL LETTERS SHALL BE CAPITALIZED, 3/8" WHITE LETTERING ON RED BACKGROUND, ARIAL OR SIMILAR FONT, NON-BOLD; REFLECTIVE, ON WEATHER- RESISTANT <br />MATERIAL SUITABLE FOR THE ENVIRONMENT (USE UL-969 AS STANDARD FOR WEATHER RATING) WILL BE USED; DURABLE ADHESIVE MATERIALS MEET THIS REQUIREMENT. <br />WHEN 120% RULE USED, TO BE INSTALLED NEXT TO THE BACKFED <br />BREAKER AT MAIN ELECTRICAL SERVICE & SUBPANEL TIE-IN LOCATIONS: <br />D1 WARNING - INVERTER OUTPUT CONNECTION. DO NOT <br />RELOCATE THIS OVERCURRENT DEVICE <br />WARNING: THIS EQUIPMENT FED BY MULTIPLE SOURCES <br />TOTAL RATING OF ALL OVERCURRENT DEVICES <br />EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE <br />SHALL NOT EXCEED AMPACITY OF BUSBAR <br />WHEN 120% RULE IS NOT USED, <br /> TO BE INSTALLED NEXT TO THE BACKFED BREAKER AT <br />MAIN ELECTRICAL SERVICE & SUBPANEL TIE-IN LOCATIONS: <br />D2 <br />SERVICE POINT & <br />UTILITY METERING <br />PV LOAD CENTER (ON ROOF) <br />PV DISCONNECT FOR <br />UTILITY OPERATION <br />Bldg permit # 101111576 <br />Plng approved by F. Arias <br />Bldg approved by J.Lo on 9/20/22 <br />Elect permit # 20177059 approved on 8/10/22 by M. Smith <br />Permits issued on 1/10/23 <br />2030 N Tustin Ave - <br />101111576 & <br />2017705901/10/23