Laserfiche WebLink
WARNING: PHOTOVOLTAIC <br />POWER SOURCE <br /> SOLAR PV BREAKER <br />BREAKER IS BACKFED <br /> DO NOT RELOCATE <br />! WARNING ! <br />ELECTRICAL SHOCK HAZARD <br />DO NOT TOUCH TERMINALS. <br />TERMINALS ON BOTH LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION. <br />PHOTOVOLTAIC SYSTEM <br />AC DISCONNECT <br />WARNING <br />DUAL POWER SUPPLY <br />SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM <br />ELECTRIC SHOCK HAZARD <br />DO NOT TOUCH TERMINALS <br />TERMINALS ON BOTH THE LINE AND LOAD SIDES <br />MAY BE ENERGIZED IN THE OPEN POSITION. <br />OPERATING VOLTAGE: 240 VOLTS <br />OPERATING CURRENT: 11.25 AMPS <br />CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED <br />PHOTOVOLTAIC POWER SOURCE <br />OPERATING AC VOLTAGE: 240 V <br />MAXIMUM OPERATING <br />AC OUTPUT CURRENT: 11.25 A <br />TO BE PLACED ON ALL INTERIOR & EXTERIOR <br />PV CONDUITS, RACEWAYS, ENCLOSURE, CABLE <br />ASSEMBLES, EVERY 10 FEET, 1' FROM TURNS <br />AND ABOVE AND BELOW PENETRATIONS AND <br />ALL DC COMBINER AND JUNCTION BOXES <br />SIGNAGE <br />PHOTOVOLTAIC SYSTEM <br />COMBINER PANEL <br />DO NOT ADD LOADS <br />NOTES: <br />ALL LABELS WILL BE ON RESISTANT MATERIAL <br />SUITABLE FOR THE ENVIRONMENT <br />ALL LABELS SHALL HAVE A RED BACKGROUND <br />WITH MIN. 3/8" WHITE LETTERING <br />TO BE PLACED ON MAIN SERVICE PANEL <br />TO BE PLACED ON SOLAR SUB PANEL <br />TO BE PLACED ON MAIN SERVICE PANEL TO BE PLACED INSIDE MAIN SERVICE PANEL <br />NEXT TO SOLAR BREAKER <br />TO BE PLACED ON DISCONNECT <br />TO BE PLACED ON DISCONNECT <br />PHOTOVOLTAIC SYSTEM <br />EQUIPPED WITH <br />RAPID SHUTDOWN <br />TO BE PLACED ON <br />MAIN SERVICE PANEL <br />WARNING <br />DUAL POWER SUPPLY <br />SOURCES: UTILITY GRID AND <br />PV SOLAR ELECTRIC SYSTEM <br />TO BE PLACED ON MAIN SERVICE PANEL <br />CAUTION: <br />POWER TO THIS BUILDING IS ALSO SUPPLIED FROM A <br />PHOTOVOLTAIC SYSTEM WITH DISCONNECTS <br />LOCATED AS SHOWN <br />TO BE PLACED ON MAIN SERVICE PANEL <br />SOLAR PV SYSTEM EQUIPPED WITH <br />RAPID SHUTDOWN <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE <br />"OFF" POSITION TO <br />SHUTDOWN PV SYSTEM <br />AND REDUCE <br />SHOCK HAZARD <br />IN THE ARRAY <br />RAPID SHUT DOWN SWITCH <br />FOR SOLAR PV SYSTEM <br />TO BE PLACED ON AC DISCONNECT <br />LABEL FOR PV SYSTEMS THAT SHUT DOWN <br />THE ARRAY AND THE CONDUCTORS LEAVING THE ARRAY Drawing <br />Signage <br />Issue Date <br />11/17/2021 <br />J <br />U <br />A <br />N <br /> <br />D <br />E <br /> <br />L <br />E <br />O <br />N <br />20 <br />3 <br />0 <br /> <br />W <br /> <br />9 <br />T <br />H <br /> <br />S <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />PH <br />O <br />N <br />E <br />: <br /> <br />( <br />7 <br />1 <br />4 <br />) <br /> <br />5 <br />4 <br />1 <br />- <br />8 <br />8 <br />6 <br />8 <br />NE <br />X <br />U <br />S <br /> <br />E <br />N <br />E <br />R <br />G <br />Y <br /> <br />S <br />Y <br />S <br />T <br />E <br />M <br />S <br />28 <br />1 <br />0 <br /> <br />H <br />A <br />R <br />B <br />O <br />R <br /> <br />B <br />L <br />V <br />D <br /> <br />S <br />U <br />I <br />T <br />E <br /> <br />2 <br />0 <br />1 <br />OX <br />N <br />A <br />R <br />D <br />, <br /> <br />C <br />A <br /> <br />9 <br />3 <br />0 <br />3 <br />5 <br />CL <br />A <br />S <br />S <br /> <br />B <br />CA <br /> <br />L <br />I <br />C <br />E <br />N <br />S <br />E <br /> <br /># <br />3 <br />5 <br />9 <br />0 <br />6 <br />0 <br />Designed by <br /> AMRUTESH VYAS <br />REV 1 <br />Drawing <br />PV-5 <br />(N)AC DISCONNECT <br />(N)ENPHASE AC <br />COMBINER PANEL <br />(N)MAIN SERVICE PANEL <br />(N)J-BOX <br />(N)CONDUIT RUN 1" ABOVE <br />ROOF BETWEEN ARRAYS <br />20 <br />3 <br />0 <br /> <br />W <br /> <br />9 <br />T <br />H <br /> <br />S <br />T <br />2030 W. Ninth <br />Street02/23/22