My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2045 W Martha Ln - Plan
PBA
>
Building
>
ProjectDox
>
M
>
Martha Ln
>
2045 W Martha Ln
>
2045 W Martha Ln - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2025 1:40:13 PM
Creation date
5/30/2025 8:00:52 AM
Metadata
Fields
Template:
Plan
Permit Number
20174637
101108410
Full Address
2045 W Martha Ln
Document Relationships
101108410 - Permit
(Permit - Plan)
Path:
\Building\Permits\M\Martha Ln\2045 W Martha Ln
20174637 - Permit
(Permit - Plan)
Path:
\Building\Permits\M\Martha Ln\2045 W Martha Ln
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
19'-8" <br />46 <br />' <br />- <br />0 <br />" <br />22'-7" <br />33 <br />' <br />- <br />2 <br />" <br />72 <br />' <br />-8 <br />" <br />114 <br />' <br />-3" <br />11 <br />6 <br />' <br />- <br />1 <br />1 <br />" <br />69'-7" <br />48'-1" <br />MSP <br />AC <br />D <br />INV <br />UM <br />1 <br />PROJECT DESCRIPTION: <br />PLOT PLAN & VICINITY MAP <br />SCALE: 1/16" = 1'PV-1 <br />SCALE: NTS PV-1 <br />PLOT PLAN & <br />VICINITY MAP <br />10X355 LONGI SOLAR:LR4-60HPB 355M 355W MODULE <br />ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES <br />SYSTEM SIZE: 3.55KW DC STC,3.8 kW AC CEC <br />REV <br />SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />ANSI B <br />11" X 17" <br />DATE DESCRIPTION <br />REVISIONS <br />Signature with Seal <br />PROJECT NAME & ADDRESS <br />PV-1 <br />PROJECT ID <br />EL <br />A <br />I <br />N <br />E <br /> <br />H <br />O <br />F <br />F <br />M <br />A <br />N <br />N <br />20 <br />4 <br />5 <br /> <br />W <br /> <br />M <br />A <br />R <br />T <br />H <br />A <br /> <br />L <br />N <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />, <br />U <br />S <br />A <br />FRESH09/27/2021 ORIGINAL PLAN <br />2065 W OBISPO AVE #102 <br />GILBERT, AZ 85233 USA <br />866-572-2637 <br />LIC # CA-1019100 <br />ABHISHEK MAHESH <br />KABILAN SELVARANGAN <br /> ROOF ACCESS POINT <br />ROOF ACCESS POINT SHALL NOT BE LOCATED IN <br />AREAS THAT DO NOT REQUIRE THE PLACEMENT <br />OF GROUND LADDERS OVER OPENINGS SUCH <br />AS WINDOWS OR DOORS, AND LOCATED AT <br />STRONG POINTS OF BUILDING CONSTRUCTION <br />IN LOCATIONS WHERE THE ACCESS POINT DOES <br />NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS <br />SUCH AS TREE LIMBS, WIRES OR SIGNS. <br />ARRAY LOCATIONS <br />VICINITY MAP <br />SCALE: NTSPV-1 <br />2 HOUSE PHOTO <br />EQUIPMENT SUMMARY <br />10 - LONGI SOLAR:LR4-60HPB 355M 355W MODULES <br />01 - SOLAREDGE TECHNOLOGY:SE3800H-US (240V) INVERTER <br />10 - SOLAREDGE POWER OPTIMIZER P-401 <br />PROJECT SITE <br />SHEET INDEX <br />PV-1 PLOT PLAN & VICINITY MAP <br />PV-2 ROOF PLAN & MODULES <br />PV-3 STRING LAYOUT <br />PV-4 ATTACHMENT DETAIL <br />PV-5 ELECTRICAL LINE DIAGRAM <br />PV-6 WIRING CALCULATIONS <br />PV-7 PLACARDS <br />PV-8 OPTIMIZER CHART <br />PV-9+ EQUIPMENT SPECIFICATIONS <br />3 <br />PAGE 1 OF 13 <br />NOTES <br />1. NOTIFY SERVING UTILITY BEFORE <br />ACTIVATION OF PV SYSTEM. <br />2. MANUFACTURERS PRODUCT INSTALLATION <br />INSTRUCTIONS SHALL BE AVAILABLE AT <br />THE TIME OF INSPECTION. <br />3. ALL SUBMITTALS WILL COMPLY WITH 2019 <br />CEC, CBC, AND CFC. <br />4. SMOKE ALARMS AND CARBON MONOXIDE <br />DETECTOR EQUIPMENT SHALL BE IN PLACE <br />AT RESIDENCE ACCORDING TO THE CRC, <br />CBC R314-315 REQUIREMENT. <br />AHJ - SANTA ANA <br />UTILITY - SCE <br />ACCOUNT # - CA-R-179164 <br />GOVERNING CODES <br />THIS PROJECT SHALL COMPLY WITH THE <br />FOLLOWING CODE <br />2019 CALIFORNIA ELECTRICAL CODE <br />2019 CALIFORNIA RESIDENTIAL CODE <br />2019 CALIFORNIA BUILDING CODE <br />2019 CALIFORNIA FIRE CODE <br />2019 CALIFORNIA GREEN BUILDING <br />STANDARDS CODE <br />2019 CALIFORNIA ENERGY CODE <br />2019 CALIFORNIA PLUMBING CODE <br />2020 NATIONAL ELECTRICAL CODE <br />ALL OTHER ORDINANCES ADOPTED BY <br />THE LOCAL GOVERNING AGENCIES. <br />ROOF #03 <br />(3) LONGI SOLAR LR4-60HPB <br />355M 355W MODULES <br />(E) DETACHED <br />STRUCTURE <br />(E) MAIN SERVICE PANEL, <br />200A RATED, 240V, <br />(N) SOLAREDGE TECHNOLOGY : <br />SE3800H-US INVERTER <br />INTEGRATED RAPID SHUTDOWN <br />(N) AC DISCONNECT <br />(E) UTILITY METER <br />ROOF ACCESS POINT <br />W MA <br />R <br />T <br />H <br />A <br /> <br />L <br />N <br />(E) GATE <br />(E) FENCE <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />LIN <br />E <br />PROPERTY LINE <br />PRO <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />NE <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />IN <br />E <br />1-STO <br />R <br />Y <br />HOUS <br />E <br />PRO <br />P <br />E <br />R <br />T <br />Y <br /> <br />LINE <br />EXISTIN <br />G <br />DRIVE <br />WAY <br />ROOF #02 <br />(2) LONGI SOLAR LR4-60HPB <br />355M 355W MODULES <br />ROOF #01 <br />(5) LONGI SOLAR LR4-60HPB <br />355M 355W MODULES <br />Bldg permit#101108410 <br />Elect permit#20174637 <br />Issued 11/10/2021 <br />2045 W Martha Ln <br />12/13/21
The URL can be used to link to this page
Your browser does not support the video tag.