CAUTION ! <br />POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE <br />FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN <br />21 <br />0 <br />2 <br /> <br />W <br /> <br />M <br />O <br />O <br />R <br />E <br /> <br />A <br />V <br />E <br />(E)UTILITY METER <br /> 1 ( SERVICE PANEL <br />WITH (() MAIN BREAKER <br /> 1 COMBINER BOX 4 <br /> 1 PV MODULES <br />SHEET NAME <br />SHEET NUMBER <br />PV-5 <br />PROJECT NAME <br />VA <br />N <br /> <br />Q <br />U <br />A <br />C <br />H <br />21 <br />0 <br />2 <br /> <br />W <br /> <br />M <br />O <br />O <br />R <br />E <br /> <br />A <br />V <br />E <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br />C <br />A <br />, <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br /> <br />U <br />S <br />A <br />AP <br />N <br /># <br /> <br />4 <br />1 <br />2 <br />0 <br />9 <br />3 <br />2 <br />2 <br />UT <br />I <br />L <br />I <br />T <br />Y <br />: <br /> <br />S <br />C <br />E <br />AH <br />J <br />: <br /> <br />C <br />I <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />SHEET SIZE <br />ANSI B <br />11" X 17" <br />DEL MAR, CA 92014, USA <br />REVDATE DESCRIPTION <br />VERSION <br />UR08/19/2022 INITIAL RELEASE <br />WARNING LABELS & <br />PLACARD <br />WARNING <br />DUAL POWER SOURCES <br />SECOND SOURCE IS <br />PHOTOVOLTAIC SYSTEM <br />WARNING <br />POWER SOURCE OUTPUT <br />CONNECTION - DO NOT RELOCATE <br />THIS OVERCURRENT DEVICE. <br />REQ'D BY & 705.12 (B)(3) <br />APPLY TO: <br />MAIN SERVICE PANEL <br />LOAD CENTER <br />COMBINER BOX <br />INVERTER <br />AT EACH AC DISCONNECTS MEANS <br />[CEC 690.13(B) AND 690.54] <br />AT POINT OF INTERCONNECTION <br />OVERCURRENT DEVICE <br />REQ'D BY CEC 705.12 (B)(2)(3)(B) <br />PHOTOVOLTAIC SYSTEM AC DISCONNECT <br />RATED ACOPERATING CURRENT 21.78 AMPS <br />AC NOMINAL OPERATING VOLTAGE 240 VOLTS <br />LABEL LOCATION: <br />CONDUIT, RACEWAYS, AND J-BOXES <br />(LABELED EVERY 10') <br />(PER CODE: CEC690.31(G)(3) <br />   <br />    <br />LABEL LOCATION: <br />RAPID SHUTDOWN <br />(PER CODE: CEC 690.56(C)(3) <br />CAUTION <br />PHOTOVALTAIC SYSTEM <br />CIRCUIT IS BACKFED <br />LABEL LOCATION: <br />AT MAIN SERVICE PANE, PULL BOXES <br />[CEC 705.12(B)(3)]AT RAPID SHUTDOWN SYSTEM <br />[CEC 690.56(C)(1)(A)] <br />LABEL LOCATION <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />SOLAR ELECTRIC <br />PV PANELS <br />2102 W Moore Ave <br />01/30/23