Laserfiche WebLink
Ur <br />b <br />a <br />n <br /> <br />E <br />n <br />e <br />r <br />g <br />y <br /> <br />S <br />o <br />l <br />a <br />r <br />, <br /> <br />I <br />n <br />c <br />. <br />10 <br />1 <br />9 <br />2 <br /> <br />C <br />o <br />n <br />s <br />t <br />i <br />t <br />u <br />t <br />i <br />o <br />n <br /> <br />D <br />r <br />i <br />v <br />e <br />Hu <br />n <br />t <br />i <br />n <br />g <br />t <br />o <br />n <br /> <br />B <br />e <br />a <br />c <br />h <br />, <br /> <br />C <br />A <br />92 <br />6 <br />4 <br />6 <br />(5 <br />6 <br />2 <br />) <br /> <br />4 <br />4 <br />7 <br /> <br />4 <br />9 <br />7 <br />1 <br />C- <br />4 <br />6 <br /> <br />L <br />i <br />c <br />. <br /> <br /># <br />9 <br />4 <br />4 <br />1 <br />1 <br />5 <br />8280 W DC <br />7497 W CEC-AC <br />APN: 396-292-06 <br />Drawn by: M.A. <br />Date: 03/15/2022 <br />PV-4 <br />Notes & Signage <br />Ma <br />n <br />z <br />o <br />, <br /> <br />G <br />e <br />n <br />a <br />e <br /> <br />& <br /> <br />J <br />a <br />v <br />i <br />e <br />r <br />21 <br />0 <br />6 <br /> <br />D <br />e <br />o <br />d <br />a <br />r <br /> <br />S <br />t <br />r <br />e <br />e <br />t <br />Sa <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />Contractor’s Signature <br />Notes: <br />1. Utility is 120V/240V 1Ø3W. <br />2. PV System is Utility Interactive. <br />3. Inverter is fully compliant with 2019 CEC 705.40 concerning Lack of Interactive System Power. <br />4. All PV system components shall be listed by a recognized testing agency. <br />5. Wiring material shall be suitable for the sun exposure and wet locations. <br />6.Where the terminal of the disconnecting means may be energized in the open position, a warning sign shall <br />be mounted on or adjacent to the disconnecting means. The sign shall be clearly legible and have the <br />following words or equivalent: “WARNING - ELECTRIC SHOCK HAZARD, DO NOT TOUCH TERMINALS. <br />TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION." <br />7. Signs shall be posted adjacent to each PV disconnect and inverter to indicate, "Photovoltaic System”. <br />8. All PV modules and associated equipment and wiring material shall be protected from any physical damage. <br />9. In one- and two-family dwelling, live parts in PV source circuits and PV output circuits over 150 Volts to <br />ground shall not be accessible to other than qualified persons while energized. <br />10. All field installed junction, pull and outlet boxes located behind modules or panels shall be accessible <br />directly or by displacement of a module(s) or panel(s) secured by removable fasteners. <br />11. Pressure terminals tightened to the recommended torque specification <br />12. Crimp-on terminals listed and installed with listed crimping tools by the same manufacturer. <br />13. User accessible fuses in "touch-safe" holders or capable of being changed without touching live contacts. <br />Signage: <br />Signage material shall be reflective, weather-resistant <br />material suitable for the environment. <br />All signage shall fall within the format: <br />Minimum 3/8” Letter Height All Letters Shall be <br />Capitalized Arial or Similar Font, Non-Bold <br />On DC Conduit, Raceways, Enclosures, Cable <br />Assemblies, DC Combiners and Junction Boxes: <br />Markings shall be placed every 10 feet on all interior <br />and exterior DC conduits, raceways, enclosures, and <br />cable assemblies, at turns above and / or below <br />penetrations, all DC combiners, and junction boxes. <br />“WARNING: PHOTOVOLTAIC POWER SOURCE” <br />30.13 <br />240 <br />CAUTION <br />PV MODULES <br />MAIN SERVICE PANEL <br />COMBINER PANEL <br />urbanenergysolar.com <br />(562) 447-4971 CSLB# 944115 <br />POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES <br />WITH DISCONNECTS LOCATED AS SHOWN <br />PARAMETERS <br />2106 Deodar <br />04/14/22