Laserfiche WebLink
GENERAL <br />NOTES & <br />SIGNAGE <br />PV-5 <br />Solar Contractors Inc. <br />ADDRESS: <br />5628 Baldwin Ave. <br />Temple City, CA 91780 <br />CONTACT NAME(S): <br />Alan Shih <br />PHONE: 626-353-4787 <br />LICENSE TYPE: B, C-46 <br />LICENSE #: 1007552 <br />CONTRACTOR: <br />PROJECT <br />INFORMATION: <br />Do Residence <br />ADDRESS: <br />2050 Rembrandt <br />Santa Ana, CA 92704 <br />OWNER NAME(S): <br />Tuan Do <br />PHONE: 812-272-8351 <br />EMAIL: tuandns@gmail.com <br />SYSTEM DC: 12.54 kW <br />SYSTEM AC: 11.268 kW <br />8/18/2021 <br />ALAN SHIH <br />AS INDICATED <br />REV DESCRIPTION DATE <br />DATE <br />SCALE <br />DRAWN BY <br />GENERAL ELECTRICAL REQUIREMENTS. <br />1.ALL EQUIPMENT SHALL BE UL-LISTED FOR THE APPLICATION. <br />2.ALL WORK SHALL COMPLY WITH 2013 CALIFORNIA BUILDING CODE, 2013 CALIFORNIA ELECTRIC <br />CODE, ARTICLE 690, AND ALL MANUFACTURER'S LISTINGS AND INSTALLATION INSTRUCTIONS. <br />INSTALLER IS ENCOURAGED TO FOLLOW NEC-2011 WITH A FOCUS ON ARTICLE 690. <br />3. NO PIPING, DUCTS OR EQUIPMENT FOREIGN TO ELECTRICAL EQUIPMENT SHALL BE PERMITTED TO <br />BE LOCATED WITHIN THE DEDICATED SPACE ABOVE THE ELECTRICAL EQUIPMENT. <br />4.ALL INSTALLED EQUIPMENT TO CONFORM TO NEC 690.61, AN INVERTER OR AN AC MODULE IN AN <br />INTERACTIVE SOLAR PHOTOVOLTAIC SYSTEM SHALL AUTOMATICALLY DE-ENERGIZE ITS OUTPUT <br />TO THE CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF <br />VOLTAGE IN THAT SYSTEM AND SHALL REMAIN IN THAT STATE UNTIL THE ELECTRICAL <br />PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED. <br />5.SYSTEM VOLTAGE CALCULATIONS ARE BASED ON EXPECTED AMBIENT TEMPERATURE OF #°C TO <br />##°C. <br />6.ALL INSTALLED EQUIPMENT SHALL BE RATED FOR USE WITH CONDUCTORS RATED FOR 90'C. <br />7.ALL CONDUCTORS SHALL BE COPPER AND SUITABLE FOR WET LOCATIONS. <br />8.WIRE TYPE TO BE THWN-2 90DEG C OR EQUAL, EXCEPT THOSE IN FREE AIR, IN FREE AIR USE <br />USE-2. <br />9.ALL MC CONNECTORS BETWEEN MODULES SHALL BE MC4 TYPE OR EQUIVALENT AND CONNECT <br />INSULATED WIRES RATED FOR 90' C AND WET AND EXPOSED CONDITIONS. <br />10.CLEAR WORKING SPACE ABOUT EQUIPMENT TO BE PROVIDED AS REQUIRED BY CEC 110.26. NO <br />APPARATUS OR OTHER EQUIPMENT FOREIGN TO THE ELECTRICAL INSTALLATION SHALL BE <br />LOCATED IN THE DEDICATED EQUIPMENT SPACE <br />11.UNDERGROUND CONDUIT RUNS SHALL BE BURIED TO AN 18" MINIMUM DEPTH, EXCEPT WHERE <br />UNDER PARKING LOTS & DRIVEWAYS. A 24" MINIMUM DEPTH UNDER PARKING LOTS & DRIVEWAYS <br />IS REQUIRED. ALL BELOW GRADE RUNS SHALL HAVE THEIR LOCATION IDENTIFIED BY A WARNING <br />RIBBON THAT IS PLACED IN THE TRENCH AT LEAST 12" ABOVE THE UNDERGROUND INSTALLATION <br />12.ALL INSTALLATION IS ABOVE GROUND. <br />13.ALL FITTINGS AND HUBS SHALL BE RATED FOR RAIN OR WET LOCATION AND COMPLY WITH UL <br />514B. <br />14.WHERE A CONDUIT ENTERS A BOX, FITTING OR OTHER ENCLOSURE, A GROUNDING WIRE IS USED. <br />BONDING JUMPERS TO BE INSTALLED AROUND CONCENTRIC OR ELECTRIC KNOCKOUTS. <br />15.GROUNDING METHOD SHALL BE CONTINUOUS AND SUCH THAT REMOVAL OF ANY PIECE OF <br />EQUIPMENT SHALL NOT INTERRUPT THE GROUNDING OF ANY OTHER PIECE OF EQUIPMENT. <br />16.WHERE EVER FIRE RATED BUILDING ASSEMBLIES ARE PENETRATED, SEAL PENETRATION WITH <br />FIRE-RATED SEALANT SO AS TO MAINTAIN REQUIRED RATING PER CBC, CHAPTER 7. <br />17.INVERTERS TO BE INSTALLED HAVE BEEN TESTED AND LISTED BY UNDERWRITERS LABORATORIES <br />TO MEET THE REQUIREMENTS OF UL1741 STATIC INVERTERS AND CHARGE CONTROLLERS FOR <br />USE IN PV POWER SYSTEMS AND UL1998 SOFTWARE PROGRAMMABLE COMPONENTS, AS WELL AS <br />IEEE-929-2000. <br />18.DC CONDUCTOR SIZING BASED ON ISC MINIMUM AMPACITY PER NEC 690.9. TEMPERATURE <br />DERATING BASED ON TABLE 310.16, CALC'D AT 90 DEGREES C. CONDUCTOR DERATING BASED ON <br />NEC 310.15(B)(2)(A) AND ON NUMBER OF CURRENT CARRYING CONDUCTORS IN CONDUIT. <br />CONDUIT SIZE PER NEC ANNEX C, TABLE C1. <br />19.DC DISCONNECT LOCATION SHALL BE IN COMPLIANCE WITH NEC690.14(C)(1). READILY <br />ACCESSIBLE, OUTSIDE OF STRUCTURE OR IF INSIDE, NEAREST TO SYSTEM CONDUCTOR <br />ENTRANCE POINT. <br />20.DC EQUIPMENT GROUND-CONTINUOUS DC GEC-BOND DIRECTLY TO MAIN AC GEC <br />21.INDIVIDUALLY GROUND ALL MODULE FRAMES, RAILS AND MOUNTING STRUCTURE USING BARE <br />COPPER WIRE EMPLOYING SEPARABLE CONNECTION IN ACCORDANCE WITH NECK 250.124(A). <br />USE APPROVED LAY-UP LUGS ATTACHED WITH STAINLESS STEAL: 18-8 GRADE OR HIGHER, 24 OR <br />32 THREADS PER INCH. <br />22.EQUIPMENT GROUNDING CONDUCTORS SMALLER THAN 6 AWG SHALL BE PROTECTED FROM <br />PHYSICAL DAMAGE BY RACEWAY OR CABLE ARMOR EXCEPT WHERE NOT SUBJECT TO OR WHERE <br />PROTECTED FROM PHYSICAL DAMAGE. <br />23.AC, DC DISCONNECT AND ALL OTHER APPLICABLE EQUIPMENT TO BE LABELED PER 690.54 AD A <br />POWER SOURCE WITH OPERATING CURRENT & SHORT CIRCUIT CURRENT. <br />24.CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO CONSTRUCTION <br />25.SPLICING CONNECTORS: POLARIS CONNECTORS <br />26.DC ARRAY CONDUCTORS ARE TO REMAIN OUTSIDE OF BUILDING PRIOR TO FUSEABLE COMBINER <br />BOX OR FUSEABLE DC DISCONNECTING MEANS. FUSEABLE DISCONNECTING MEANS IS REQUIRED <br />OUTSIDE OF THE BUILDING, §690.14(C)(1) <br />27.INSPECTION REQUIRED FOR ROOF CONNECTION MOUNTING ASSEMBLIES PRIOR TO INSTALLATION <br />OF SOLAR MODULE. <br />28.THE RESPONSIBILITY OF RE-CERTIFYING WINDOWS PER NFRC IS REQUIRED AND PROVIDED BY THE <br />ARCHITECT. <br />29.EQUIPMENT OVER 600 VOLTS SHALL COMPLY WITH ARTICLE 490 <br />30.FOR CIRCUITS OVER 250 VOLTS TO GROUND, THE ELECTRICAL CONTINUITY OF METAL RACEWAYS <br />SHALL BE ENSURED BY CONNECTIONS USING THREADED COUPLINGS OR LISTED DEVICES SUCH <br />AS BONDING TYPE LOCKNUTS OR BUSHINGS WITH BONDING JUMPERS. <br />31.RACEWAYS FOR GEC SHALL BE BONDED AT EACH END. <br />32.FOR DC EQUIPMENT INSTALLED ON THE ROOF, CONDUIT, WIRING SYSTEMS, AND RACEWAYS <br />SHALL BE LOCATED AS CLOSE AS POSSIBLE TO THE RIDGE, HIP, OR VALLEY AND SHALL RUN FROM <br />THE RIDGE, HIP, OR VALLEY DIRECTLY TO AN OUTSIDE WALL. DC COMBINER BOXES SHALL BE <br />LOCATED SO AS TO MINIMIZE CONDUIT RUNS IN PATHWAYS BETWEEN ARRAYS. DC WIRING <br />LOCATED INSIDE BUILDING SHALL BE RUN IN METALLIC CONDUIT OR IN RACEWAYS AND SHALL BE <br />RUN ALONG THE BOTTOM OF LOAD BEARING STRUCTURAL FRAMING MEMBERS WHEREVER <br />FEASIBLE. <br />33.DIRECT-CURRENT PHOTOVOLTAIC SOURCE AND OUTPUT CIRCUIT OF A UTILITY INTERACTIVE <br />INVERTER FROM A BUILDING INTEGRATED OR OTHER PHOTOVOLTAIC SYSTEM SHALL BE RUN <br />OUTSIDE A BUILDING UNLESS CONTAINED IN METALLIC RACEWAYS OR ENCLOSURES FROM THE <br />POINT OF PENETRATION OF THE SURFACE OF THE BUILDING OR STRUCTURE TO THE FIRST <br />READILY ACCESSIBLE DISCONNECTING MEANS. <br />WARNING <br />ELECTRIC SHOCK HAZARD IF A <br />GROUND FAULT IS INDICATED <br />NORMALLY GROUNDED <br />CONDUCTORS MAY BE <br />UNGROUNDED AND ENERGIZED <br />CAUTION:SOLAR CIRCUIT <br />PHOTOVOLTAIC DISCONNECT <br />WARNING <br />ELECTRIC SHOCK HAZARD <br />DO NOT TOUCH TERMINALS <br />TERMINALS ON BOTH LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />WARNING <br />INVERTER OUTPUT CONNECTION <br />DO NOT RELOCATE THIS <br />OVERCURRENT DEVICE <br />PV SYSTEM AC DISCONNECT <br />RATED AC OUTPUT CURRENT (A): 47.85A <br />NOMINAL OPERATING AC VOLTAGE (V): 240V <br />NEC 690.5(c) <br />PLACE THIS LABEL ON INVERTER(S) OR <br />NEAR GROUND FAULT INDICATOR <br />NEC 690.14 (C)(2) <br />PLACE THIS LABEL ON ALL DISCONNECTING MEANS <br />NEC 690.17 <br />PLACE THIS LABEL ON ALL DISCONNECTING MEANS <br />WHERE ENERGIZED IN AN OPEN POSITION <br />PLACE MARKINGS EVERY 10FT ON ALL INTERIOR AND EXTERIOR DC CONDUIT, <br />RACEWAYS, ENCLOSURES AND CABLE ASSEMBLIES, ALL TURNS, ABOVE AND <br />BELOW PENETRATIONS, ALL DC COMBINERS, AND JUNCTION BOXES IN 3/8" <br />WHITE LETTERING ON RED BACKGROUND, ON FADE RESISTANT MATERIAL <br />*ROOFTOP DISCONNECT SHALL BE PERMANENTLY LABELED IN <br />REFLECTIVE, FADE RESISTANT MATERIAL STATING "EMERGENCY <br />DISCONNECT" <br />NEC 690.64(B)(7) <br />PLACE THIS LABEL AT POC TO SERVICE DISTRIBUTION <br />EQUIPMENT (I.E. SUB OF MAIN PANEL) <br />NEC 690.14, 690.15, 690.54 <br />PLACE THIS LABEL AT "INTERCONNECTIVE POINT OF <br />INTERCONNECTION" (I.E. CONNECTION W/ UTILITY SERVICE SUCH AS MSP) <br />PV EQUIPMENT LABELS AND NOTES: <br />1. LABEL "CAUTION: SOLAR CIRCUIT" SHALL BE ON ALL EXPOSED CONDUIT, <br />ENCLOSURES, CABLE ASSEMBLIES, JUNCTION BOXES. <br />2.LABELS SHALL HAVE WHITE LETTERING WITH RED BACKGROUND. <br />3.LABELS LETTERING SHALL BE ALL CAPITAL LETTERS, ARIAL OR EQUAL FONT, <br />AND A MINIMUM OF 3/8" HEIGHT AND SIZE. <br />4.LABELS MINIMUM SIZE (HEIGHT =4", WIDTH =4") <br />5.LABELS SHALL BE REFLECTIVE, WEATHER RESISTANT MATERIAL. <br />6.ALL PV SYSTEM COMPONENTS SHALL BE LISTED BY A RECOGNIZED TESTING <br />AGENCY. <br />7.WIRING MATERIAL SHALL BE SUITABLE FOR SUN EXPOSURE AND WET <br />LOCATIONS. FILED APPLIED PROTECTIVE COATINGS ARE NOT ACCEPTABLE. <br />8.SIGNS SHALL BE POSTED ADJACENT TO EACH PV DISCONNECT AND INVERTER <br />TO INDICATE "PHOTOVOLTAIC SYSTEM" <br />9.ALL PV MODULES AND ASSOCIATED EQUIPMENT AND WIRING MATERIAL SHALL <br />BE PROTECTED FROM ANY PHYSICAL DAMAGE. <br />10.ALL FIELD INSTALLED JUNCTION, PULL AND OUTLET BOXES LOCATED BEHIND <br />MODULES OR PANELS SHALL BE ACCESSIBLE DIRECTLY OR BY DISPLACEMENT <br />OF A MODULE(S) OR PANELS(S) SECURED BY REMOVABLE FASTENERS. <br />11.THE ROOF MOUNTED PHOTOVOLTAIC MODULES, PANELS, OR SOLAR VOLTAIC <br />ROLL ROOFING MATERIAL SHALL HAVE THE SAME OR BETTER LISTED <br />FIRE-RESISTANCE RATING THAN THE BUILDING ROOF-COVERING MATERIAL. <br />§690.5(C) <br />LABELS AND MARKINGS: A WARNING LABEL SHALL APPEAR ON THE UTILITY-INTERACTIVE <br />INVERTER OR BE APPLIED BY INSTALLER NEAR THE GROUNG-FAULT INDICATER AT <br />A VISSIBLE LOCATION, SATTING THE FOLLOWING: <br />WARNING <br />ELECTRICAL SHOCK HAZARD <br />IF A GROUND FAULT IS INDICATED, <br />NORMALLY GROUNDED CONDUCTORS <br />MAY BE UNGROUNDED AND ENERGIZED <br />WHEN THE PHOTOVOLTAIC SYSTEM ALSO HAS BATTERIES, THE SAME WARNING SHALL ALSO BE <br />APPLIED BY THE INSTALLER IN A VISIBLE LOCATION AT THE BATTERIES. <br />§690.14(C)(2) <br />MARKING: EACH PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS SHALL BE PERMANENTLY MARKED <br />TO IDENTIFY IT AS A PHOTOVOLTAIC SYSTEM DISCONNECT. <br />§690.15 <br />DISCONNECTION OF PHOTOVOLTAIC EQUIPMENT <br />MEANS SHALL BE PROVIDED TO DISCONNECT EQIPMENT, SUCH AS INVERTERS, BATTERIES, CHARGE <br />CONTROLLERS, AND THE LIKE, FROM ALL UNGROUNDED CONDUCTORS OF ALL SOURCES. IF THE <br />EQUIPMENT IS ENERGIZED FROM MORE THAN ONE SOURCE, THE DISCONNECTING MEANS SHALL BE <br />GROUPED AND IDENTIFIED. <br />§690.17 <br />SWITCH OR CIRCUIT BREAKER: <br />THE DISCONNECTING MEANS FOR UNGROUNDED CONDUCTORS SHALL CONSIST OF A MANUALLY <br />OPERABLE SWITCH(ES) OR CIRCUIT BREAKER(S) COMPLYING WITH ALL THE FOLLOWING <br />REQUIREMENTS: <br />1. LOCATED WHERE READILY ACCESSIBLE <br />2. EXTERNALLY OPERABLE WITHOUT EXPOSING THE OPERATOR TO CONTACT WITH LIVE PARTS <br />3. PLAINLY INDICATING WHETHER IN THE OPEN OR CLOSED POSITION <br />4. HAVING AN INTERRUPTING RATING SUFFICIENT FOR THE NOMINAL CIRCUIT VOLTAGE AND THE <br />CURRENT THAT IS AVAILABLE AT THE LINE TERMINALS OF THE EQUIPMENT <br />5. WHERE ALL TERMINALS OF THE DICONNECTING MEANS MAY BE ENERGIZED IN THE OPEN <br />POSITION, A WARNING SIGN SHALL BE MOUNTED ON OR ADJACENT TO THE DISCONNECTING <br />MEANS. THE SIGN SHALL BE CLEARLY LEGIBLE AND HAVE THE FOLLOWING WORDS: <br />WARNING <br />ELECTRICAL SHOCK HAZARD. <br />DO NOT TOUCH TERMINALS. <br />TERMINALS ON BOTH THE LINE <br />AND LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION. <br />§690.53 <br />DIRECT-CURRENT PHOTOVOLTAIC POWER SOURCE: APERMANENT LABEL FOR THE DIRECT-CURRENT <br />PHOTOVOLTAIC POWER SOURCE INDICATING ITEMS (1) THROUGH (5) SHALL BE PROVIDED BY THE <br />INSTALLER AT THE PHOTOVOLTAIC DISCONNECTING MEANS: <br />1. RATED MAXIMUM POWER-POINT CURRENT <br />2. RATED MAXIMUM POWER-POINT VOLTAGE <br />3. MAXIMUM SYSTEM VOLTAGE <br /> FPN TO (3): SEE 690.7(A) FOR MAXIMUM PHOTOVOLTAIC SYSTEM VOLTAGE. <br />4. SHORT-CIRCUIT CURRENT <br /> FPN TO (4): SEE 690.8(A) FOR CALCULATION OF MAXIMUM CIRCUIT CURRENT. <br />5. MAXIMUM RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER (IF INSTALLED) <br /> FPN: REFLECTING SYSTEMS USED FOR IRRADIANCE ENHANCEMENT MAY RESULT <br /> IN INCREASED LEVELS OF OUTPUT CURRENT AND POWER. <br />§690.54 <br />INTERACTIVE SYSTEM POINT OF INTERCONNECTION. ALL INTERACTIVE SYSTEM(S) POINTS OF <br />INTERCONNECTION WITH OTHER SOURCES SHALL BE MARKED AT AN ACCESSIBLE LOCATION AT THE <br />DISCONNECTING MEANS AS A POWER SOURCE AND WITH THE RATED MAX AC OUTPUT CURRENT AND <br />THE NOMINAL OPERATING AC VOLTAGE. <br />§690.56(B) <br />FACILITIES WITH THE UTILITY SERVICES AND PV SYSTEMS. BUILDING OR STRUCTURES WITH BOTH <br />UTILITY SERVICE AND PHOTOVOLTAIC SYSTEM SHALL HAVE A PERMANENT PLAQUE OR DIRECTORY <br />PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM <br />DISCONNECTING MEANS IF NOT LOCATED AT THE SAME LOCATION. <br />§690.64(B)4) <br />MARKING. EQUIPMENT CONTAINING OVERCURRNET DEVICES IN CIRCUITS SUPPLYING POWER TO A <br />BUSBAR OR CONDUCTOR SUPPLIED FROM MULTIPLE SOURCES SHALL BE MARKED TO INDICATE THE <br />PRESENCE OF ALL SOURCES. <br />GENERAL FIRE GUIDELINES & MARKING REQTS: <br />SEC. 5. MARKINGS, LABELS, AND WARNING SIGNS. <br />A. PURPOSE: PROVIDES EMERGENCY RESPONDERS WITH APPROPRIATE WARNING AND GUIDANCE WITH <br />RESPECT TO ISOLATING THE SOLAR ELECTRICAL SYSTEM. THIS CAN FACILITATE IDENTIFYING <br />ENERGIZED ELECTRICAL LINES THAT CONNECT THE SOLAR PANELS TO THE INVERTER, AS THESE <br />SHOULD NOT BE CUT WHEN VENTING FOR SMOKE REMOVAL. <br />B. MAIN SERVICE DISCONNECT: <br />1. RESIDENTIAL BUILDINGS: THE MARKING MAY BE PLACED WITHIN THE MAIN SERVICE <br />DISCONNECT. THE MARKING SHALL BE PLACED ON THE OUTSIDE COVER IF THE MAIN <br />SERVICE DISCONNECT IS OPERABLE WITH THE SERVICE PANEL CLOSED. <br />2. COMMERCIAL BUILDINGS: THE MARKING SHALL BE PLACED ADJACENT TO THE MAIN SERVICE <br />DISCONNECT CLEARLY VISIBLE FROM THE LOCATION WHERE THE LEVER IS OPERATED. <br />3. MARKINGS: VERBIAGE, FORMAT, AND TYPE OF MATERIAL. <br />A. VERBIAGE: <br /> CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED <br />B. FORMAT: <br /> (1) WHITE LETTERING ON A RED BACKGROUND. <br /> (2) MINIMUM 3/8 INCHES LETTER HEIGHT. <br /> (3) ALL LETTERS SHALL BE CAPITALIZED. <br /> (4) ARIAL OR SIMILAR FONT, NON-BOLD. <br />C. MATERIAL: <br /> (1) REFLECTIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR THE <br /> ENVIRONMENT (USE UL -- 969 AS STANDARD FOR WEATHER <br /> RATING). DURABLE ADHESIVE MATERIALS MEET THIS REQUIREMENT. <br />C. MARKING REQUIREMENTS ON DC CONDUIT, RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES, DC <br />COMBINERS, AND JUNCTION BOXES: <br /> 1. MARKINGS: PLACEMENT, VERBIAGE, FORMAT, AND TYPE OF MATERIAL. <br />A. PLACEMENT: MARKINGS SHALL BE PLACED EVERY 10 FEET ON ALL INTERIOR AND <br />EXTERIOR DC CONDUITS, RACEWAYS, ENCLOSURES, AND CABLE ASSEMBLIES, AT TURNS, <br />ABOVE AND FOR BELOW PENETRATIONS, ALL DC COMBINERS, AND JUNCTION BOXES. <br />B. VERBIAGE: <br />CAUTION: SOLAR CIRCUIT <br /> NOTE: THE FORMAT AND TYPE OF MATERIAL SHALL ADHERE <br /> TO "V.B-3B, C" OF THIS REQUIREMENT. <br />C. INVERTERS ARE NOT REQUIRED TO HAVE CAUTION MARKINGS. <br />SEC. 7. DIRECT CURRENT (DC) CONDUCTOR LOCATIONS. <br />A. CONDUIT, WIRING SYSTEMS, AND RACEWAYS: <br />1. LOCATED AS CLOSE AS POSSIBLE TO THE RIDGE, HIP OR VALLEY AND FROM THE HIP OR <br />VALLEY AS DIRECTLY AS POSSIBLE TO AN OUTSIDE WALL. <br />B. CONDUIT RUNS BETWEEN SUB ARRAYS AND DC COMBINER BOXES SHALL: <br />1. USE DESIGN GUIDELINES THAT MINIMIZES THE TOTAL AMOUNT OF CONDUIT USED ON THE <br />ROOF BY TAKING THE SHORTEST PATH FROM THE ARRAY TO THE DC COMBINER BOX. <br />2. THE DC COMBINER BOXES ARE TO BE LOCATED SUCH THAT CONDUIT RUNS ARE MINIMIZED <br />IN THE PATHWAYS BETWEEN ARRAYS. <br />C. DC WIRING: <br />1. DC WIRING SHALL BE RUN IN METALLIC CONDUIT OR RACEWAYS WHEN LOCATED WITHIN <br />ENCLOSED SPACES IN A BUILDING. <br />2. WHEN POSSIBLE DC WIRING SHALL RUN ALONG THE BOTTOM OF LOAD- BEARING MEMBERS. <br />SEC. 8. GROUND MOUNTED PHOTOVOLTAIC ARRAYS. <br />A. SETBACK REQUIREMENTS: <br />1. DOES NOT APPLY TO GROUND MOUNTED FREESTANDING PHOTOVOLTAIC ARRAYS. <br />2. A 10 FEET MINIMUM CLEARANCE IS REQUIRED AROUND GROUND-MOUNTED PHOTOVOLTAIC <br />SYSTEMS. <br />3. SHALL NOT OBSTRUCT FIRE DEPARTMENT ACCESS. <br />SEC. 9. OVERHEAD ARRAYS ON ROOFTOPS (E.G. TRELLIS SYSTEMS). <br />A. MINIMUM REQUIREMENTS: <br />1. OVERHEAD ARRAYS SHALL COMPLY WITH THE SAME MARKING, LABELING, AND WARNING <br />SIGNS AS REQUIRED OF ROOF-MOUNTED SYSTEMS. <br />2. THERE SHALL BE AN UNOBSTRUCTED CLEARANCE OF SEVEN FEET OR MORE BETWEEN THE <br />ROOF DECK SURFACE AND THE UNDERSIDE OF THE OVERHEAD ARRAY. <br />3. THE REGULATIONS IN 57.12.03, AND 57.138.04 OF THE LOS ANGELES FIRE CODE SHALL BE <br />COMPLIED WITH. <br />4. AN UNINTERRUPTED SECTION OF SOLAR PHOTOVOLTAIC PANELS SHALL NOT EXCEED 150 <br />FEET BY 150 FEET IN DIMENSION IN EITHER AXIS. <br />5. THE OVERHEAD CLEAR WIDTH BETWEEN ARRAYS OR SUB-ARRAYS SHALL BE FOUR FEET OR <br />GREATER EXTENDING FROM THE EDGE OF THE ARRAY(S) TO THE ROOF DECK SURFACE, <br />THEREBY, MAINTAINING AN UNOBSTRUCTED ACCESS PATHWAY, AND PROVIDING FOR <br />EMERGENCY VENTILATION PROCEDURES. THE USE OF THE AREA BELOW ARRAYS IS <br />PROHIBITED. <br />WARNING <br />DUAL POWER SOURCES <br />SECOND SOURCE IS PHOTO-VOLTAIC SYSTEM <br />RATED AC OUTPUT CURRENT (A): 47.85A <br />AC NORMAL OPERATING VOLTAGE (V): 240V <br />NEC 690.54 <br />PLACE THIS LABEL MAIN SERVICE PANEL <br />PHOTOVOLTAIC SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />NEC 690.56 (c) <br />PLACE THIS LABEL AT RAPID SHUT DOWN DISCONNECT WHERE RAPID SHUT DOWN IS <br />INSTALLED <br />2050 W Rembrandt <br />09/28/21