My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2114 1%2 N Candis Ave - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Candis Ave
>
2114 1/2 N Candis Ave
>
2114 1%2 N Candis Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2025 1:40:33 PM
Creation date
5/30/2025 8:00:52 AM
Metadata
Fields
Template:
Plan
Permit Number
20178811
101113991
Full Address
2114 1/2 N Candis Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
WARNING! <br />THIS EQUIPMENT FED BY MULTIPLE <br />SOURCES. TOTAL RATING OF ALL <br />OVERCURRENT DEVICES EXCLUDING <br />MAIN SUPPLY OVERCURRENT DEVICE <br />SHALL NOT EXCEED AMPACITY OF <br />BUSBAR. <br />TO BE INSTALLED AT MAIN SERVICE PANEL. <br />SIGNAGE NOTES: <br />ALL SIGNAGE SHALL BE REFLECTIVE, UV RESISTANT PLASTIC, RED IN COLOR <br />WITH WHITE LETTERING, AND ATTACHED WITH WEATHERPROOF ADHESIVE <br />OR OTHER APPROVED METHOD. ALL LETTERS SHALL BE A MINIMUM OF <br />3/8" HEIGHT AND ALL CAPITALIZED. <br />ALL CONDUIT, JUNCTION BOXES AND OTHER ENCLOSURES SHALL BE <br />MARKED AT 10' MAX INTERVALS AND AT ALL BENDS, TERMINATIONS, <br />SPLICES OR CONNECTIONS WITH "WARNING: PHOTOVOLTAIC POWER <br />SOURCE". <br />NUMBER OF MODULES IN CIRCUIT#1 = 3 <br />MODULE MAX OUTPUT CURRENT = 1.45A <br />(3)(1.45A)(1.25) = 5.44A[Ic], USE 20A BREAKER <br />NOTE: DISTANCE ABOVE ROOF TO BOTTOM OF <br />CONDUIT: >23mm (7/8") <br />FROM THE MODULES TO THE HUB+: <br />AMBIENT TEMPERATURE = 34°C <br />ADJUSTMENT FACTOR PER TABLE 310.15(B)(2)(b) FOR 90°C <br />INSULATED CONDUCTOR AT 34°C = 1.05 <br />Ic = 5.44A <br />5.44A/1.05 = 5.18A <br />NUMBER OF CURRENT CARRYING CONDUCTORS IN CONDUIT = 2 <br />ADJUSTMENT FACTOR PER TABLE 310.15(B)(3)(a) FOR CONDUIT <br />FILL (1-3 CONDUCTORS IN CONDUIT)=1 <br />5.18A/1= 5.18A <br />SELECT WIRE SIZE WITH AMPACITY GREATER THAN 5.18A, USE 10 <br />AWG THWN-2 COPPER WIRE WITH AN AMPACITY OF 40A. <br />SELECT CONDUIT FOR (2)10 AWG THWN-2 & (1)8 AWG GROUND <br />= 3/4" EMT CONDUIT. <br />2114 1/2 CANDIS AVE, SANTA ANA, CA 92706 <br />POWER TO THIS BUILDING ALSO SUPPLIED <br />FROM THE FOLLOWING SOURCES WITH <br />DISCONNECTS LOCATED AS SHOWN: <br />CAUTION: <br />SERVICE BY QUALIFIED PERSONNEL ONLY <br />TO BE INSTALLED ON THE OUTSIDE COVER <br />OF THE MAIN SERVICE DISCONNECT: <br />WARNING! <br />ELECTRIC SHOCK HAZARD <br />TERMINALS ON BOTH LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE <br />"OFF" POSITION TO <br />SHUT DOWN PV SYSTEM <br />AND REDUCE <br />SHOCK HAZARD <br />IN THE ARRAY <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />SOLAR ELECTRIC <br />PV PANELS <br />TO BE INSTALLED AT ALL SERVICEABLE <br />PANELS OR BOXES AND AT ALL DISCONNECTS. <br />CAUTION <br />TRI POWER SOURCES <br />SECOND SOURCE IS AC BATTERY <br />THIRD SOURCE IS PV SYSTEM <br />TO BE INSTALLED AT MAIN SERVICE PANEL. <br />WARNING! <br />PHOTOVOLTAIC POWER SOURCE <br />TO BE INSTALLED ON JUNCTION BOXES <br />AND CONDUIT EVERY 10'. <br />TO BE INSTALLED ON OR NO MORE THAN 1M (3FT) <br />FROM THE SERVICE DISCONNECTING MEANS TO <br />WHICH THE PV SYSTEMS ARE CONNECTED. <br />ENERGY STORAGE SYSTEM <br />CONTAINS ENERGIZED BATTERIES <br />TO BE INSTALLED AT SUNVAULT ENERGY <br />STORAGE SYSTEM. <br />NO BRANCH CIRCUIT LOADS LARGER <br />THAN 35 AMPS MAY BE INSTALLED <br />IN THIS SUBPANEL <br />TO BE INSTALLED AT HUB+. <br />ENERGY STORAGE SYSTEM <br />DISCONNECT <br />TO BE INSTALLED AT SUNVAULT ENERGY <br />STORAGE SYSTEM. <br />PV SOLAR BREAKER <br />DO NOT RELOCATE THIS <br />OVERCURRENT DEVICE <br />TO BE INSTALLED AT HUB+. <br />ESS BREAKER <br />DO NOT RELOCATE THIS <br />OVERCURRENT DEVICE <br />TO BE INSTALLED AT HUB+. <br />ECOSOLAR USA <br />ELECTRICAL LLC <br />13962 SEABOARD CIRCLE <br />GARDEN GROVE, CA 92840 <br />PH: 714.265.9077 <br />SCOPE OF WORK: <br />DAVID Q HOANG C10 - 1045300 <br />DATE: <br />DRAWN BY: <br />HOMEOWNER: <br />ADDRESS: <br />CHECKED BY: <br />R.A. <br />S.C.INSTALL (1) A400-G-AC AND (2)A415-G-AC SOLAR ELECTRIC MODULES ON THE EXISTING 1ST <br />STORY COMP SHINGLE ROOF. INSTALL ASSOCIATED MOUNTING HARDWARE, JUNCTION <br />BOXES, CONDUIT, CONDUCTORS AND GROUNDING. CONNECT TO THE (N)20A BREAKER <br />INSTALLED IN THE EXISTING SUNPOWER HUB+ GENERATION BUS. <br />REV DESCRIPTION DATE <br />A UPDATED ADDRESS 01.21.2023 <br />B UPDATED AHJ <br />ADAPTED CODES 02.04.2023 <br />HAO NGUYEN <br />(949)205-9259 <br />02.04.2023 <br />2114 1/2 CANDIS AVE <br />SANTA ANA, CA 92706 <br />PV3 <br />SYSTEM SIGNAGE <br />SYSTEM CALCULATIONS: <br />WIRE CALCULATIONS: <br />SOLAR ARRAY <br />(ON ROOF) <br />SUBPANEL (INSIDE) <br />SUNPOWER HUB+ <br />SERVICE POINT AND <br />UTILITY METERING <br />SUNPOWER ESS <br />2114 1%2 N <br />Candis Ave02/23/23
The URL can be used to link to this page
Your browser does not support the video tag.