Laserfiche WebLink
THREE (3) RIGID <br />CONDUITS INSIDE <br />COLUMN FOR POWER & <br />DATA LINES. SEE <br />DETAIL 2/A1.0 FOR <br />PLACEMENT. <br />VAR <br />I <br />E <br />S <br />- <br />S <br />E <br />E <br /> <br />SHE <br />E <br />T <br /> <br />E1.0 <br />COLUMN <br />THREE (3) RIGID CONDUITS IN <br />FLOOR FOR POWER AND DATA <br />LINES PER DIMENSION NOTED <br />ON E1.0 POWER PLAN TO <br />CENTER OF STUB UP <br />FINISHED WALL <br />INSTALL NEW IG <br />DUPLEX RECEPTACLE <br />3/4" RIGID CONDUIT 6" <br />AFF WITH TWO (2) <br />PULL STRINGS ONLY <br />INSTALL NEW <br />NETWORK DATA JACK <br />INSTALL NEW IG <br />QUAD RECEPTACLE <br />3/4" RIGID CONDUIT TO <br />DUPLEX RECEPTACLE <br />VIA TRENCH <br />STO <br />R <br />E <br /> <br />ENT <br />R <br />A <br />N <br />C <br />E <br />INSTALL NEW IG <br />QUAD RECEPTACLE <br />NOTE: <br />FACE OF RECEPTACLE AND DATA <br />OUTLETS ARE TO FACE STOCK ROOM <br />WALL. FAILURE TO MEET THE <br />REQUIREMENT WILL RESULT IN <br />RE-INSTALLATION AT CONTRACTOR'S <br />EXPENSE <br />INSTALL NEW <br />NETWORK DATA JACK <br />INSTALL NEW IG <br />QUAD RECEPTACLE <br />4'-0" O.C.6'-0" O.C. <br />FINISHED <br />FLOOR <br />15 <br />" <br /> <br />A <br />F <br />F <br /> <br />M <br />A <br />X <br />15 <br />" <br /> <br />A <br />F <br />F <br />12" MAX <br />15 <br />" <br /> <br />A <br />F <br />F <br /> <br />M <br />A <br />X <br />FAILURE TO MEET THESE REQ'D <br />DIMENSIONS WILL RESULT IN <br />RE-INSTALLATION AT <br />CONTRACTOR'S EXPENSE <br />3/4" RIGID CONDUIT 6" AFF WITH TWO <br />(2) PULL STRINGS ONLY (REFER TO <br />POWERED KEY NOTE "2D") <br />1.5" RIGID CONDUIT W/ DATA LINES <br />(REFER TO POWERED KEY NOTE "2C") <br />3/4" RIGID CONDUIT W/ DEDICATED <br />POS CIRCUIT (REFER TO POWERED <br />KEY NOTES "2A", "2B", & "2F") <br />3/4" RIGID CONDUIT W/ DEDICATED <br />CIRCUIT (REFER TO POWERED KEY <br />NOTES "2A" & "2B") <br />3/4" RIGID CONDUIT W/ <br />DEDICATED CIRCUIT <br />(REFER TO POWERED <br />KEY NOTES "2A" & "2E") <br />RECEPTACLE & DATA PORT <br />NETWORK JACKS <br />RECEPTACLE & DATA PORT <br />NETWORK JACKS <br />1.5" RIGID CONDUIT W/ DATA LINES <br />(REFER TO POWERED KEY NOTE "2C") <br />CASH & WRAP <br />NETWORK JACK 1 <br />R2 <br />RJ45 <br />3 <br />RJ45 <br />P2 <br />4 <br />MANAGER & TRAINING <br />NETWORK JACK <br />R1 <br />RJ45 RJ45 <br />P1 <br />RJ45 <br />SS <br />RJ45 <br />UC <br />RJ45 <br />NP <br />RJ45 <br />MT1 <br />RJ45 <br />MT2 <br />CASH & WRAP <br />NETWORK JACK 2 <br />DATA PORT 4: P2 VIA CAT-6 WIRE <br />DATA PORT 3: R2 VIA CAT-6 WIRE <br />TO DATA RACK PATCH PANEL <br />1 2 <br />8 <br />7 <br />25 26 <br />DATA PORT 31: SS VIA CAT-6 WIRE <br />DATA PORT 2: P1 VIA CAT-6 WIRE <br />DATA PORT 1: R1 VIA CAT-6 WIRE <br />OPEN <br />DATA PORT 8 UC VIA CAT-6 WIRE <br />DATA PORT 7: NP VIA CAT-6 WIRE <br />DATA PORT 26: MT2 VIA CAT-6 WIRE <br />DATA PORT 25: MT1 VIA CAT-6 WIRE <br />31 <br />TO DATA RACK PATCH PANEL <br />OPEN <br />OPEN OPEN <br />OPEN OPEN <br />OPEN <br />OPEN <br />OPEN <br />OPEN <br />OPEN <br />OPEN <br />OPEN <br />OPEN <br />DATA PORT 32: CCTV VIA CAT-6 WIRE <br />RJ45 <br />CCTV <br />32 <br />OPEN <br />OPEN <br />PATCH PANEL DETAIL <br />1 <br />R1 <br />2 <br />P2 <br />3 <br />R2 <br />4 <br />P2 <br />5 6 7 <br />NP <br />8 <br />UC <br />9 10 11 12 13 14 15 16 <br />AP1 <br />17 <br />AP2 <br />18 19 20 21 22 23 24 <br />MT1 MT2 SM1 <br />37 38 39 40 41 42 43 44 45 46 47 4831 32 33 34 35 36 25 26 27 28 29 30 <br />SS CCTV HVAC AV1 AV2 AV3 AV4 AV5 <br />LTE AP3 <br />WHITE/BROWN <br />2 <br />1 <br />6 <br />3 <br />8 <br />7 <br />4 <br />5 <br />BROWN <br />CAT6 CONNECTOR <br />CAT6 CABLE <br />DATA <br />WHITE/BLUE <br />BLUE <br />WHITE/GREEN <br />GREEN <br />B B <br />ORANGE <br />GUARDIAN <br />SECURITY <br />PANEL <br />48 PORT PATCH PANEL <br />C111 VERIZON CISCO ROUTER <br />POWER DISTRIBUTION UNIT <br />MUSIC AMPLIFIER SYSTEM <br />TRIPP LITE - SMART UPS <br />VERASYS <br />SMART BUILDING HUB <br />WIFI CLIENT EOL <br />WIFI AP SYSTEM BUS <br />USB B USB A <br />UPGRADE RUN <br />LINK ETHERNET <br />FAULT POWER <br />RESET REBOOT <br />RTU-1 RTU-2 <br />RTU-3 RTU-4 <br />8' <br />- <br />0 <br />" <br />4'-0" <br />4' <br />- <br />0 <br />" <br />PROGRAMMABLE <br />SWITCH BANK(#14) <br />TWO (2) SECURITY <br />QUAD OUTLETS <br />(#13) <br />H1 <br />CAT 6 CABLE FOR <br />CONNECTION TO H1 <br />ON PATCH PANEL. <br />TELEPHONE BACKBOARD <br />(4' x 8' x 3/4" PLYWOOD) <br />CONDUIT WITH <br />CIRCUIT FOR <br />POWER <br />CONNECTION <br />EMS SYSTEM <br />MOUNTED ON <br />BACKBOARD <br />SYSTEM. <br />DATA RACK QUAD <br />OUTLET (#13) <br />EMS QUAD <br />OUTLET (#13) <br />RACK-MOUNTED UPS SYSTEM TO <br />CONNECT TO POWER <br />DISTRIBUTION UNIT. <br />DATA RACK PER KEYED NOTE. <br />SEE RESPONSIBILITY SCHEDULE. <br />MUSIC AMPLIFIER - <br />PROVIDED AND INSTALLED BY <br />MUSIC SERVICE PROVIDER. <br />POWER DISTRIBUTION UNIT <br />TO BE MOUNTED IN RACK. <br />48 PORT PATCH PANEL. PUNCH <br />DOWN ALL DROPS PER <br />LABELED PORTS AND PATCH <br />OVER TO ROUTER. SEE PATCH <br />PANEL DETAIL FOR PORTS AND <br />LABELS TO BE USED. <br />C1111 VERIZON NETWORK <br />ROUTER (PROVIDED BY IT) <br />2" PVC CONDUIT TO RUN 12" <br />ABOVE CEILING FOR <br />LOW-VOLTAGE CAT 6 CABLES. <br />AREA FOR <br />ADDITIONAL <br />NETWORK <br />EQUIPMENT. <br />POWER <br />CONNECTION TO <br />EMS SYSTEM <br />CONDUIT WITH <br />CIRCUIT FOR <br />POWER <br />CONNECTION <br />POWER <br />CONNECTION TO <br />UPS SYSTEM IN <br />DATA RACK <br />CISCO 24 PORT SWITCH <br />CISCO 24-PORT SWITCH TO BE <br />PATCHED FROM PATCH PANEL <br />PER DETAIL. <br />SPACER(S) <br />GROUNDING PLATE/BAR <br />SHELF - USED FOR MUSIC & A/V EQUIPMENT <br />SPACER(S) <br />SHELF - USED FOR CABLE MODEM(S) AND EQUIPMENT <br />VENTED SHELF <br />VENTED SHELF <br />3'-0" 3'-0" 3'-0" <br />STANDARD <br />3' <br />- <br />1 <br />" <br />TRAINING AREA <br />QUADPLEX MTD <br />HORIZONTAL <br />3' <br />- <br />1 <br />" <br />FINISHED FLOOR <br />3' <br />- <br />0 <br />" <br />3'-0" 3'-0" <br />MANAGER'S DESK <br />QUADPLEX MTD <br />HORIZONTAL <br />FINISHED FLOOR <br />SECURITY EQUIP <br />QUADPLEX MTD <br />HORIZONTAL MANAGER AND TRAINING NETWORK JACK <br />3' <br />- <br />0 <br />" <br />SEE DETAIL 6/E4.0 FOR DATA WIRING DETAILS. <br />STANDARD <br />3'-0" <br />08/04/22 <br />SHEET NUMBER <br />RE <br />V <br />I <br />S <br />I <br />O <br />N <br />S <br />SH <br />E <br />E <br />T <br /> <br />M <br />A <br />N <br />A <br />G <br />M <br />E <br />N <br />T <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />I <br />N <br />F <br />O <br />R <br />M <br />A <br />T <br />I <br />O <br />N <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />O <br />. <br />: <br />DA <br />T <br />E <br /> <br />I <br />S <br />S <br />U <br />E <br />D <br />: <br />DR <br />A <br />W <br />N <br /> <br />B <br />Y <br />: <br />RE <br />V <br />I <br />E <br />W <br />E <br />D <br /> <br />B <br />Y <br />: <br />SEAL <br />Corporate Office: <br />3025 Highland Parkway | Suite 850 <br />Downers Grove, IL 60515 <br />info@sevansolutions.com <br />www.sevansolutions.com <br />INTEGRITY | RESPECT | TEAMWORK <br />EXCELLENCE | CHARITY <br />DESIGN SOLUTIONS, P.C. <br />27 <br />0 <br />0 <br /> <br />M <br />I <br />L <br />A <br />N <br /> <br />C <br />O <br />U <br />R <br />T <br />, <br /> <br />B <br />I <br />R <br />M <br />I <br />N <br />G <br />H <br />A <br />M <br />, <br /> <br />A <br />L <br /> <br />3 <br />5 <br />2 <br />1 <br />1 <br />CO <br />N <br />T <br />A <br />C <br />T <br /> <br />H <br />I <br />B <br />B <br />E <br />T <br />T <br /> <br />C <br />O <br />N <br />S <br />T <br />R <br />U <br />C <br />T <br />I <br />O <br />N <br /> <br />D <br />E <br />P <br />A <br />R <br />T <br />M <br />E <br />N <br />T <br />@ <br />( <br />2 <br />0 <br />5 <br />) <br /> <br />9 <br />4 <br />2 <br />- <br />4 <br />2 <br />9 <br />2 <br />15 <br />4 <br />0 <br />07 <br />/ <br />0 <br />1 <br />/ <br />2 <br />2 <br />GR <br />S <br />NO <br />. <br />DA <br />T <br />E <br />DE <br />S <br />C <br />R <br />I <br />P <br />T <br />I <br />O <br />N <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />22 <br />0 <br />5 <br />8 <br />0 <br />SE <br /> <br />J <br />O <br />B <br /># <br />: <br />New York Omaha HonoluluMiami Los Angeles Seattle <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />21 <br />3 <br />0 <br /> <br />E <br /> <br />1 <br />7 <br />T <br />H <br /> <br />S <br />T <br />. <br />- <br />- <br />- <br />- <br />- <br />- <br />EL <br />E <br />C <br />T <br />R <br />I <br />C <br />A <br />L <br /> <br />D <br />E <br />T <br />A <br />I <br />L <br />S <br />E4.0 <br />1 <br />E4.0 <br /> CASH WRAP DETAIL <br />1/2" = 1'-0"SCALE: <br />GENERAL ELECTRICAL NOTES <br />5 <br />E4.0 <br />BACKBOARD AND DATA RACK ELEVATION <br />NOT TO SCALE <br />3 <br />E4.0 <br />NOT USED <br />1/2" = 1'-0"SCALE: <br />2 <br />E4.0 <br /> CASH WRAP ELEVATION <br />1" = 1'-0"SCALE: <br />6 <br />E4.0 <br />DATA WIRING DETAIL <br />6" = 1'-0"SCALE: <br />4 <br />E4.0 <br />PATCH PANEL DETAIL <br />3" = 1'-0"SCALE: <br />7 <br />E4.0 <br />CAT6 PLUG WIRING DETAIL <br />NOT TO SCALE <br />JM <br />S <br />2130 E 17th St - <br />10111279406/07/23