ESR-1308 | Most Widely Accepted and Trusted Page 7 of 21 <br />Table 1607.1 and Item 31 of 2009 IBC Table 1607.1, <br />as applicable. <br />5.9 The supporting construction for the ceiling system has <br />not been evaluated and is outside the scope of this <br />report. The code official must approve the floor or roof <br />construction supporting the suspended ceiling system. <br />5.10 The ceiling systems recognized in this report have <br />been evaluated for use in interior applications. For <br />exterior ceiling systems must be designed for wind <br />loads and with due consideration of atmospheric <br />conditions. <br />5.11 Lay-in ceiling panels must be justified to the <br />satisfaction of the code official as complying with the <br />interior finish requirements of Chapter 8 of the <br />applicable code. <br />5.12 The electrical safety of the EAC main runners is <br />outside the scope of this report. EAC main runners <br />must be installed in accordance with the applicable <br />provisions of the National Electrical Code. <br />5.13 Suspended ceiling system with 730145 main runner, <br />and XL7325 and XL7345 cross runners have only been <br />evaluated for gravity loads only. Seismic design is <br />outside the scope of this report. <br />6.0 EVIDENCE SUBMITTED <br />6.1 Data in accordance with the ICC-ES Acceptance <br />Criteria for Suspended Ceiling Framing Systems <br />(AC368), dated November 2019 (editorially revised <br />March 2021). <br />6.2 Reports of fire-resistance tests in accordance with <br />ASTM E119. <br />6.3 Reports of comparative seismic qualification tests in <br />accordance with the ICC-ES Acceptance Criteria for <br />Seismic Certification by Shake-table Testing of <br />Nonstructural Components (AC156), dated October <br />2010 (editorially revised December 2020). <br />7.0 IDENTIFICATION <br />7.1 Cartons of framing members, clips and accessories <br />are identified with the name and address of Armstrong <br />World Industries, Inc.; the catalog number; the word <br />“WAVE”; and the ICC-ES evaluation report number <br />(ESR-1308). <br />7.2 The report holder’s contact information is the following: <br />WORTHINGTON ARMSTRONG VENTURE (WAVE) <br />101 LINDENWOOD DRIVE, SUITE 350 <br />MALVERN, PENNSYLVANIA 19355 <br />(610) 722-1218 <br />www.armstrongceilings.com <br />jrameen@armstrongceilings.com <br />7.3 The Additional Listee’s contact information is the <br />following: <br />ARMSTRONG WORLD INDUSTRIES, INC. <br />POST OFFICE BOX 3001 <br />LANCASTER, PENNSYLVANIA 17604 <br />TABLE 1—ACOUSTICAL MATERIALS <br />ACOUSTICAL PANEL SIZE (inches)ACOUSTICAL MATERIAL TYPE1 STEEL FLOOR DECK PANEL TYPE2 <br />0 by 60 <br />20 by 60 <br />24 by 24 <br />24 by 24 <br />24 by 24 or 36 <br />24 by 24 or 36 <br />24 by 24 or 36 <br />24 by 48 or 60 <br />24 by 48 or 60 <br />30 by 30 <br />30 by 30 <br />30 by 30 <br />30 by 60 <br />36 by 36 <br />36 by 36 <br />36 by 60 <br />48 by 48 <br />P(S OR P) OR PC(S) <br />P(S OR P) OR PC(S) <br />BF(S) <br />BF(S) <br />P(S) <br />PC(S) <br />P(S) <br />P(S OR P) OR PC(S) <br />P(S OR P) OR PC(S) <br />P(S) <br />PC(S) <br />P(S) <br />P(S) OR PC(S) <br />PC(S) <br />PC(S) <br />PC(S) <br />PC(S) <br />F, C or B <br />F or B1 <br />F, C or B <br />F <br />F, C or B <br />C or B <br />F <br />F, C or B <br />F or B1 <br />F, C or B <br />C or B <br />F <br />F, C or B <br />F, C or B <br />F or B1 <br />F, C or B <br />F, C or B <br />For SI: 1 inch = 25.4 mm. <br />1(S) = surface perforations, (P) = through perforations. <br />2(F) = all fluted steel deck panels, (C) = all cellular steel floor deck panels, (B) = any blend of fluted and cellular floor deck panels, (B1) = blend of one cellular floor <br />deck panels and one or more fluted deck panels. <br /> <br />2130 E 17th St - <br />10111279406/07/23