My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2202 N Freeman St - Plan
PBA
>
Building
>
ProjectDox
>
F
>
Freeman St
>
2202 N Freeman St
>
2202 N Freeman St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2025 1:40:33 PM
Creation date
5/30/2025 8:00:52 AM
Metadata
Fields
Template:
Plan
Permit Number
20175064
101109040
Full Address
2202 N Freeman St
Document Relationships
101109040 - Permit
(Permit - Plan)
Path:
\Building\Permits\F\Freeman St\2202 N Freeman St
20175064 - Permit
(Permit - Plan)
Path:
\Building\Permits\F\Freeman St\2202 N Freeman St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
22 <br />22 <br />340W <br />* 340 <br />Q.PEAK DUO BLK-G6+ 340 <br />318.1W <br />* 318.1 * <br />1.0 <br />97% <br />1.0 <br />0.97 <br />IQ7-60-2-US (CEC)22 <br />FROM JBOX TO IQ COMBINER BOX <br />FROM IQ COMBINER BOX TO PV LOAD CENTER <br />1 1/2'' <br /> TEMP. DERATE FACTOR (TEMP - 39 + 22 = 61C)0.58 <br /> RACEWAY HEIGHT FROM ROOF <br />PV SYSTEM <br />AS INDICATED <br />OCTOBER 15, 2021 <br />PAUL ZIESMER <br />2202 FREEMAN ST <br />SANTA ANA, CA 92706 <br />CONTRACTOR <br />Current Insight, LLC <br />2852 W. Amini Way <br />South Jordan, UT <br />84095 <br />EXO ENERGY <br />Address: <br />1247 Simpson Way <br />Escondido, CA 92029 <br />Phone Number: <br />208-351-4153 <br />CSLB:#1063308 <br />Drafted By: <br />3 <br />WIRE SIZE <br />CALCULATIONSFROM PV MODULES TO JBOX <br /> #12 AWG ENPHASE TRUNK CABLE, PV WIRE(4) 1 <br />(1) #6 AWG BARE CU EGC <br />2 <br /> #8 AWG CU EGC, <br />(3) <br />3 <br />(1) #8 AWG CU EGC, <br /> MAXIMUM INVERTER OUTPUT CURRENT <br /> WALL TEMPERATURE FACTOR <br />OUTPUT CALCULATIONS <br />PV SYSTEM MAX DC OUTPUT <br />PV SYSTEM MAX AC OUTPUT <br />1.25 <br />0.91 <br />(4) <br />(1) <br />22 <br /> Pmax (PTC Rating) <br />3/4'' EMT TYPE CONDUIT <br />3/4'' EMT TYPE CONDUIT <br />#10 AWG THWN-2 <br />WIRE CHART WIRE CHART <br />a b <br />2 BRANCH CIRCUITS <br /> INVERTER OUTPUT MAX CURRENT <br /> COEFFICIENT 1.25 <br />13 <br /> BRANCH CIRCUIT CURRENT a: 13 BREAKER SIZE PER BRANCH CRCT <br />20A <br />0.8ADJST. FACTOR (4 thru 6 WIRES) <br />* *1.25131.0 16.3A <br /> ADJUSTED CONDUCTOR AMPACITY <br />/ / 16.3 0.58 0.8 35.1A <br /> NUMBER OF MICROINVERTERS <br /> 7.48KW <br />6.79KW <br />WIRE CHART <br />QTY <br /> CONSIDER CONTINUOUS COEFFICIENT <br /> CONSIDER CONTINUOUS (A)1.25* *22 1.0 27.5 <br />*1.25 / 0.91*22 1.0 30.2 <br /> #10 AWG THWN-2 <br /> TEMPERATURE ADJUSTMENT (A) <br />22 <br />Attention!!!!!!! <br />Need Calculation <br />(don't delete this note) <br />9 <br /> BRANCH CIRCUIT CURRENT b: 9 BREAKER SIZE PER BRANCH CRCT <br />20A* *1.259 1.0 11.3A <br />MAIN SERVICE PANEL RATING <br />BUSBAR RATING <br />MAIN BREAKER <br />PV BACKFEED BREAKER SIZE <br />120% RULE: <br />MAX ALLOWED FEED <br />60A <br />175A <br />200A <br />240A <br />175A''MB'' + 60A "SOLAR" = 235A ≤240A MAX <br />(3) <br />4 <br />(1) #8 AWG CU EGC, <br /> MAXIMUM INVERTER OUTPUT CURRENT (A) <br /> TEMPERATURE FACTOR <br /> TEMPERATURE ADJUSTMENT (A) <br />1.25 <br />0.91 <br /> #6 AWG THWN-2 <br />44.0 * 1.25 / 0.91 <br />22.0 + 22.0 = 44.0 <br />60.4 <br />44.0 * 1.25 55.0 <br />3/4'' EMT TYPE CONDUIT <br /> CONSIDER CONTINUOUS COEFFICIENT <br />FROM PV LOAD CENTER TO MAIN SERVICE PANEL <br /> CONSIDER CONTINUOUS (A) <br />2202 N Freeman St <br />03/30/22
The URL can be used to link to this page
Your browser does not support the video tag.