Laserfiche WebLink
2 <br />SINGLE LINE <br /> DIAGRAM <br />PV SYSTEM <br />AS INDICATED <br />JANUARY 11, 2022 <br />PAUL ZIESMER <br />2202 FREEMAN ST <br />SANTA ANA, CA 92706 <br />CONTRACTOR <br />Current Insight, LLC <br />2852 W. Amini Way <br />South Jordan, UT <br />84095 <br />EXO ENERGY <br />Address: <br />1247 Simpson Way <br />Escondido, CA 92029 <br />Phone Number: <br />208-351-4153 <br />CSLB:#1063308 <br />Drafted By: <br />ITEM DESCRIPTION QTY# <br />PV MODULE <br />MAIN SERVICE PANEL <br />MAIN SERVICE PANEL <br />& UTILITY METER <br />BUSBAR RATING <br />BREAKER RATING <br />1 <br />ITEM DESCRIPTION QTY # <br />PVC JUNCTION BOX 4"x4"x2" UL LISTED WATER TIGHT NEMA TYPE 3 <br />1 <br />1 <br />1 <br />4 <br />3 <br />1 <br />8 <br />15A 6 <br />M <br />MAIN <br />SERVICE <br />PANEL <br />120/240V <br />1P,3W <br />2 <br />EXISTING <br />GROUNDING SYSTEM <br />UTILITY <br />22 <br />HANWHA 340W <br />Q.PEAK DUO BLK-G6+ 340 <br />Voc = 40.66V <br />Vmp = 33.94V <br />Isc = 10.52A <br />Imp = 10.02A <br />2 <br />3 <br />INVERTER <br />PEAK PWR TRACKING VOLTAGE <br />CEC EFFICIENCY <br />PROTECTION RATING: <br />MAXIMUM INPUT CURRENT <br />MAXIMUM OUTPUT CURRENT <br />MAXIMUM INPUT POWER <br />PEAK OUTPUT POWER <br />4 22 <br />27-37 V <br />97.0 % <br />NEMA 6 <br />15.0 A <br />1.0 A <br />235-350 W <br />250 W <br />Enphase Energy Microinverters (IQ7-60-2-US) <br />IQ COMBINER <br />ENPHASE IQ COMBINER BOX WITH ENPHASE ENVOY IQ <br />120/240V, NEMA 3R MODEL# X-IQ-AM1-240-3-ES <br /> INSTALL 15A PV 2-POLE C/B <br /> INSTALL 20A PV 2-POLE C/B <br />0 <br />2 <br />8 1 <br /> 15A PV 2-POLE C/B <br /> (2)#14 AWG THWN-2 (L1+L2) <br /> (1)#14 AWG-NEUTRAL <br />ENVOY <br />INFORMATION <br />60AAC DISCONNECT NON FUSED AC DISCONNECT LOCKABLE, <br />BLADE TYPE, NEMA 3R, 120/240V 16 <br />17 PV LOAD CENTER PV LOAD CENTER <br />120/240 1P/3W 125A <br />EXISTING <br />(DOWNSIZED) <br />PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN <br />AND COMPLIANT WITH NEC 690.12 <br />Branch a: (13) Modules, (13) Microinverters <br />2 <br />1 <br />(D)175A <br />3 <br />175A <br />200A <br />200A <br />FOR WIRE SIZE CALCULATIONS PLEASE SEE PAGE #3 <br />20A <br />EXISTING <br />CONDUIT <br />EXISTING PHOTOVOLTAIC ARRAY <br />18 SOLAR WORLD 250W MODULES <br />EXISTING <br />SB 5000TL-US-22 <br />SOLAR INVERTER <br />EXISTING <br />CONDUIT <br />EXISTING <br />CONDUIT <br />M <br />EXISTING <br />PERFORMANCE <br />METER <br />EXISTING <br />CONDUIT <br />Branch b: (9) Modules, (9) Microinverters <br />20A <br />7 <br />4 <br />EXISTING <br />CONDUIT <br />EXISTING <br />AC DISCONNECT <br />INSTALL 2P <br />60A CB(PV) AT <br />OPPOSITE END <br />OF BUS FROM <br />MAIN FEEDER CB <br />EXISTING <br />JBOX <br />4 <br />30A <br />30A <br />RAPID SHUTDOWN <br />RAPID SHUTDOWN <br />Both system have Rapid Shutdowns <br />2202 N Freeman St <br />02/08/22