10.52 A <br />CODE REQUIRED <br />SIGNAGE <br />4 <br />PV SYSTEM <br />AS INDICATED <br />JANUARY 11, 2022 <br />PAUL ZIESMER <br />2202 FREEMAN ST <br />SANTA ANA, CA 92706 <br />CONTRACTOR <br />Current Insight, LLC <br />2852 W. Amini Way <br />South Jordan, UT <br />84095 <br />EXO ENERGY <br />Address: <br />1247 Simpson Way <br />Escondido, CA 92029 <br />Phone Number: <br />208-351-4153 <br />CSLB:#1063308 <br />Drafted By: <br />60 Hz <br />250 W <br />N/A <br />NEC 690.56(C)(3) <br />DO NOT UPSIZE MAIN BREAKER. MAIN <br />BREAKER WAS DOWNSIZED TO A <br />TO ACCOMMODATE PV SYSTEM. <br />CAUTION <br />POWER TO THIS BUILDING IS ALSO SUPPLIED <br />FROM THE FOLLOWING SOURCES WITH <br />DISCONNECTS LOCATED AS SHOWN: <br />NEC 705.10(B) & NEC 690.56(B) <br />Permanent directory or plaque providing location of service disconnecting means and <br />photovoltaic system disconnecting means, if not located at the same location. (Plaques shall <br />be metal or plastic, with engraved or machine printed letters, or electro-photo plating, in a <br />contrasting color to the plaque. Plaques shall be permanently attached to the equipmenq or in the <br />required location using an approved method that is suitable to withstand the environment to which it <br />is exposed. Plaques and signage shall meet legibility, defacemet, exposure and adhesion <br />requirements of Underwriters Laboratories marking and labeling system 969(UL969). <br />Plaques will have red background & white lettering. <br />N <br /> 0° <br />S <br /> 180° <br />E <br /> 90° <br />W <br /> 270° <br />CONTACT EXO ENERGY SOLAR (888) 463-9667 <br />JB <br /> <br />B <br />O <br />X <br />WARNING <br />ELECTRICAL SHOCK HAZARD <br />TERMINALS ON THE LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />NEC 690.13(B) <br />TURN OFF PHOTOVOLTAIC <br />AC DISCONNECT PRIOR TO <br />WORKING INSIDE PANEL <br />NEC 110.27(C) & OSHA 1910.145(f)(7) <br />DC <br /> <br />D <br />i <br />s <br />c <br />o <br />n <br />n <br />e <br />c <br />t <br />ELECTRICAL SHOCK HAZARD <br />TERMINALS ON THE LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />NEC 690.13(B) <br />DC VOLTAGE IS ALWAYS PRESENT <br />WHEN SOLAR MODULES <br />ARE EXPOSED TO SUNLIGHT NEC 690.53 <br />NEC 690.13(B) <br />In <br />v <br />e <br />r <br />t <br />e <br />r <br /> <br />/ <br /> <br />P <br />V <br /> <br />L <br />o <br />a <br />d <br />WARNING <br />THE DISCONNECTION OF THE <br />GROUNDING CONDUCTOR(S) <br />MAY RESULT IN OVERVOLTAGE <br />ON THE EQUIPMENT <br />NEC 690.31(I) <br />NEC 690.54 <br />AC <br /> <br />D <br />i <br />s <br />c <br />o <br />n <br />n <br />e <br />c <br />t <br />NEC 690.54 <br />NEC 690.52 <br />WARNING <br />ELECTRICAL SHOCK HAZARD <br />TERMINALS ON THE LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />NEC 690.13(B) <br />PM <br /> <br />M <br />E <br />T <br />E <br />R <br />NEC 705.12(D)(3) & NEC 690.59 <br />Ma <br />i <br />n <br />/ <br />S <br />u <br />b <br /> <br />P <br />a <br />n <br />e <br />l <br />NEC 690.54 <br />NEC 690.13 (F), NEC 705.12(B)(3-4) & NEC 690.59 <br />NEC 705.12(D)(3) & NEC 690.59 <br />NEC 690.15 (C) & NEC 690.33(E)(2) <br />NEC 690.13(B) <br />SINGLE 120-VOLT SUPPLY <br />DO NOT CONNECT <br />MULTIWIRE BRANCH CIRCUIT <br />NEC 710.15(C) & 692.9 (C) <br />TURN OFF PHOTOVOLTAIC <br />AC DISCONNECT PRIOR TO <br />WORKING INSIDE PANEL <br />NEC 110.27(C) & OSHA 1910.145(f)(7) <br />WARNING <br />ELECTRICAL SHOCK HAZARD <br />TERMINALS ON THE LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />NEC 690.13(B) <br />NEC 705.12 (B)(2)(c) <br />LABELING REQUIREMENTS FOR ARTICLE 690 <br />NEC 690.13(B) Each PV system disconnecting means shall plainly indicate whether <br />in the open (off) or closed (on) position and be permanently marked “PV SYSTEM <br />DISCONNECT” or equivalent. Additional markings shall be permitted based upon <br />the specific system configuration. For PV system disconnecting means where the <br />line and load terminals may be energized in the open position, the device shall be <br />marked with the following words or equivalent. <br />NEC 690.13(F) Type of Disconnect. A dc PV system disconnecting means shall be <br />marked for use in PV systems or be suitable for backfeed operation. <br />NEC 690.15(C) An isolating device shall be rated to open the maximum circuit <br />current under load or be marked “Do Not Disconnect Under Load” or “Not for <br />Current Interrupting.” <br />NEC 690.31(B)(1) PV system circuit conductors shall be identified at all accessible <br />points of termination, connection and splices. The means of identification shall be <br />permitted by separate color coding, marking tape, tagging or other approved means. <br />NEC 690.31(G)(1) Where circuits are embedded in build up, laminate or membrane <br />roofing materials not covered by PV modules and associated equipment, the location <br />of the circuits shall be clearly marked. <br />NEC 690.31(G)(4) PV dc system circuit labels shall appear on every section of the wiring <br />system that is separated by enclosures, walls, partitions, ceilings, or floors. Spacing between <br />labels or markings, or between a label and a marking, shall not be more than 3 m (10 ft). <br />Labels required in this section shall be suitable for the environment where they are installed. <br />NEC 690.31(I) Solidly-grounded bipolar PV systems shall be clearly marked with a permanent, <br />legible warning notice indicating that the disconnection of the grounded conductor(s) may <br />result in overvoltage on the equipment. <br />NEC 690.33(E)(2) Interruption of Circuit. Connectors shall be a type that requires the use of a <br />tool to open and marked “Do Not Disconnect Under Load” or “Not for Current Interrupting.” <br />NEC 690.52 Alternating-current modules shall be marked with identification of terminals or <br />leads and with identification of the following ratings. <br />NEC 690.53A permanent label for the dc PV power source indicating items (1) through (3) <br />shall be provided by the installer at dc PV system disconnecting means and at each dc <br />equipment disconnecting means required by 690.15. Where a disconnecting means has more <br />than one dc PV power source, the values in 690.53 (1) through (3) shall be specified for each <br />source. <br />NEC 690.54 All interactive system(s) points of interconnection with other <br />sources shall be marked as an accessible location at the disconnecting <br />means as a power source and with the rated ac output current and the <br />nominal operating ac voltage. <br />NEC 690.55 The PV system output circuit conductors shall be marked to <br />indicate polarity where connected to energy storage systems. <br />NEC 690.56(B)Plaques or directories shall be installed in accordance with <br />705.10. <br />NEC 690.56(C)(3) A rapid shutdown switch shall have a label located on <br />or no more than 1 meter (3 ft) from the switch that includes the following <br />wording. <br />NEC 690.56(C)(1)(a-b) The type of PV system shall be labeled as described <br />in a) or b): <br />NEC 690.59 PV systems connected to other sources shall be installed in <br />accordance with Parts I and II of Article 705. <br />SOLAR ELECTRIC <br />PV PANELS <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />TURN RAPID SHUTDOWN <br />SWITCH ON THE <br />"OFF" POSITION TO <br />SHUTDOWN PV SYSTEM <br />AND REDUCE <br />SHOCK HAZARD <br />IN ARRAY <br />IFC 605.11.3.1(1) & 690.56(C)(1)(a) <br />NEC 690.56(C)(3) <br />NEC 690.31(G)(3)(4) <br />NEC 690.31(G)(1)CO <br />N <br />D <br />U <br />I <br />T <br />RATED AC OUTPUT CURRENT: <br />NOMINAL OPERATING AC VOLTAGE: <br />PHOTOVOLTAIC AC DISCONNECT <br />MAXIMUM VOLTAGE <br />MAXIMUM CIRCUIT CURRENT <br />MAX RATED OUTPUT CURRENT OF <br />THE CHARGE CONTROLLER <br />OR DC-TO-DC CONVERTER <br />(IF INSTALLED) <br />DC DISCONNECT <br />PHOTOVOLTAIC <br />WARNING WARNING DUAL POWER SOURCE <br />SECOND SOURCE IS PHOTOVOLTAIC SYSTEM <br />RATED AC OUTPUT CURRENT: <br />NOMINAL OPERATING AC VOLTAGE: <br />PHOTOVOLTAIC AC DISCONNECT NOMINAL OPERATING AC VOLTAGE <br />NOMINAL OPERATING AC FREQUENCY <br />MAXIMUM AC POWER <br />MAXIMUM AC CURRENT <br />MAX OVERCURRENT DEVICE RATING <br />FOR AC MODULE PROTECTION <br />RATED AC OUTPUT CURRENT: <br />NOMINAL OPERATING AC VOLTAGE: <br />PHOTOVOLTAIC AC DISCONNECT WARNING DUAL POWER SOURCE <br />SECOND SOURCE IS PHOTOVOLTAIC SYSTEM <br />MAIN PHOTOVOLTAIC <br />SYSTEM DISCONNECT WARNING <br />CAUTION <br />PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED <br />WARNING <br />POWER SOURCE OUTPUT <br />CONNECTION. DO NOT <br />RELOCATE THIS <br />OVERCURRENT DEVICE. <br />WARNING <br />DO NOT DISCONNECT <br />UNDER LOAD <br />RAPID SHUT DOWN SWITCH <br />FOR SOLAR PV SYSTEM <br />WARNING: PHOTOVOLTAIC <br />POWER SOURCE <br />WARNING <br />PHOTOVOLTAIC POWER SOURCE <br />DO NOT REMOVE UNLESS REPLACED IN EXACT LOCATION - PV POWER CIRCUIT DIRECTLY BELOW <br />WARNING <br />FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY <br />AND CONDUCTORS LEAVING THE ARRAY: SIGH TO <br />BE LOCATED ON OR NO MORE THAN 3 FT AWAY <br />FROM SERVICE DISCONNECTING MEANS TO WHICH <br />THE PV SYSTEMS ARE CONNECTED AND SHALL <br />INDICATE THE LOCATION OF ALL IDENTIFIED RAPID <br />SHUTDOWN SWITCHES IF NOT AT THE SAME <br />LOCATION. [CEC 690.56(C)(1)(A)] <br />45.5 V <br />240 Vac <br />240 Vac <br />240 Vac <br />240 Vac <br />NEC 690.13(B) <br />AC DISCONNECT <br />PHOTOVOLTAIC <br />60 A <br />22.0 A <br />22.0 A <br />22.0 A <br />22.0 A <br />Fr <br />e <br />e <br />m <br />a <br />n <br /> <br />S <br />t <br />175 <br />SERVICE POINT & <br />UTILITY METERING <br />PV SYSTEM DISCONNECT <br />FOR UTILITY OPERATION <br />PV LOAD CENTER <br />IQ COMBINER BOX <br />(E) SOLAR RS ARRAY ON <br />THE ROOF <br />(N) SOLAR RS ARRAY <br />ON THE ROOF <br />(N) SOLAR RS ARRAY <br />ON THE ROOF <br />2202 N Freeman St <br />02/08/22