Laserfiche WebLink
OCTOBER 21, 2021 <br />PV SYSTEM <br />AS INDICATED <br />California Solar Group <br />Project Name Address Project Description Contractor <br />7647 Hayvenhurst Ave., Unit 26 <br />Van Nuys, CA 91406 <br />casolargroup.com <br />info@casolargroup.com <br />Phone Number: +1 818 658 2362 <br />Address & Phone Number <br />CSLB # 1067781 <br /> Drawn By: Unique Solar Design <br />SHEET SIZE <br />11''X 17'' ANSI B <br />SHEET NUMBER <br />Company Logo Signature <br />2210 W Avalon Ave <br />Santa Ana, CA 92706Abel Marica <br />5.10KW DC Roof Mounted <br />PV Electrical System <br />15-Hanwha 340W PV Modules <br />15-IQ7Plus Enphase Microinverters <br />Note <br />G N <br />L2 <br />L1 <br />TO UTILITY GRID <br />L2 L1 <br />PV2 <br />5 <br />Photovoltaic system is rapid shut down ready <br />3 <br />... 12 1 <br />II J BOX <br />NEMA 3R <br />EQUIPMENT INFORMATION <br />1 15 (N) Hanwha 340W Modules <br />(Q.PEAK DUO BLK-G6 340) (Page D1) <br />2 15 (N) Enphase Microinverters IQ7PLUS-72-2-US <br />[240V] [SI1-JUN20] (Page D2) <br />3 2 (N) Junction-Box <br />4 1 (N) Enphase IQ Combiner Box With Enphase Envoy <br />IQ MODEL# X-1Q-AM1-240-3-ES (120/240V) (Page D3) <br />5 1 (N) 30A Non-Fused AC Disconnect (120/240V) <br />6 (E) 200A Main Service Panel (120/240V, 1ɸ, 3W) <br />PV SYSTEM OUTPUT <br />CALCULATION <br />MAX DC OUTPUT: 340W * 15 = 5.10kW <br />MAX AC OUTPUT: 318.4 W PTC * 15 <br />= 4.78kW * 0.97(CEC) = 4.64kW <br />(2) #14 AWG THWN, <br />(1) #10 AWG CU EGC <br />[C] [D] <br />WIRE TYPE/QTY/SIZE <br />COPPER <br />Enphase Q Cable <br /> (2) #10 <br />GRD-SIZE <br />#6, BARE CU <br />WIRE <br />AMP <br />TERMINAL <br />RATING CONDUIT <br />OPEN AIR <br />TEMP. <br />CORRECTION <br />0.71>3.5 - 12'' <br />AMP. ADJ <br />C.C.C <br />CURRENTWIRE <br />TAG# <br />A <br />B <br />28.4 >= 18.2A1 <br />ABOVE ROOF / <br />Through Attic <br />#8, EGC CU 0.91 36.4 >= 22.7A <br />40A 90° <br />3/4'' <br />EMT <br />40A 90° <br />C <br />ALONG <br /> THE WALL <br />3/4'' <br />EMT <br />>3.5 - 12'' <br />4 <br />(N)2P 20A <br />15A <br />N <br />G <br />(1st) SERIES OF 3 MICROINVERTERS <br />(2nd) SERIES OF 12 MICROINVERTERS <br />8' Minimum Embedment Rod at 6' <br />From Equipment Ground Conductor Unless <br />Existing Ground is UFER. <br />200A END <br />FEED MAIN <br />OCPD <br />INSTALL 2P <br />30A CB(PV) <br />FURTHEST FROM <br />MAIN FEEDER CB <br />#8, EGC CU 0.71THWN-2 (2) #10 <br />L1, L2 28.4 >= 4.5A40A 90° <br />MAIN SERVICE PANEL <br />CALCULATION <br />120/240V 1ɸ, 3W <br />BUS RATING: 200A <br /> MAIN BREAKER SIZE: 200A <br />(200A X 1.2) - 200A MAIN BREAKER <br /> = 40A >= 30A (N) SOLAR BREAKER <br />PV ARRAY A <br />HANWHA SOLAR 340W <br />(12) MODULES <br />WIRED IN (2ND) SERIES <br />OF (12) MICROINVERTERS <br />THWN-2 (3) #10 <br />(L1,L2,N)1 <br />(N)2P 20A <br />L1 <br />L2 <br />N <br />G <br />L1 <br />L2 <br />6 <br />[D] <br />2 31 <br />[A]PV ARRAY A <br />HANWHA SOLAR 340W <br />(3) MODULES <br />WIRED IN (1ST) SERIES <br />OF (3) MICROINVERTERS <br />21 <br />I J BOX <br />NEMA 3R <br />[B] <br />0.8 <br />(4 WIRES) <br />3/4'' <br />EMT >3.5 - 12''#8, EGC CU 0.71THWN-2 (4) #10 <br />L1(2), L2(2)22.7 >= 18.2A40A90° <br />1 <br />D