Laserfiche WebLink
6 Ft. <br />1. Installers to verify rafter size, spacing and sloped spans, and notify the E.O.R of any discrepancies before proceeding. <br />2. Any rotted or damaged rafters shall be replaced prior to proceeding. <br />6 Ft. <br />Digitally Signed by <br />Phong Truong, P.E. <br />Date: 2021.10.28 09:08:48 -0700 <br />SRC Job Id: 31375 <br />Ceiling Type: 1/2 gyp. Bd. <br />Collar Tie Space: 0 <br />Coverage %: 8.3 <br />Frame Size: 2x4@24 <br />Ground Snow (psf): 0 <br />Sloped Roof Snow Load (psf): 0 <br />Lag Screw Diameter (in): 5/16 <br />Lag Screw Embedment (in): 2.5 <br />Overall Span (ft): 35 <br />PV Orientation: Landscape <br />PV Weight (psf): 2.9 <br />Rafter Sloped Span (ft): 6.5 <br />Rail System: 2Rail <br />Roofing Type: Comp. Shingle <br />Roof Mean Height (ft): 20 <br />Roof Slope (degrees): 20 <br />Roof Type: Truss <br />Sloped Ceiling?: No <br />Standoff Max. Horz. Space (ft): 6 <br />Standoff Max. Vert. Space (ft): 1.708 <br />Standoff Staggered?: Yes <br />Wind Exposure: C <br />Wind Speed (mph): 110 <br />Unique Solar Design <br />13535 Valerio Street Apt 204 <br />Van Nuys, CA 91405 USA 096 <br />Abel Marica (Santa Ana) <br />2210 West Avalon Avenue <br />Santa Ana, CA 92706 10-28-2021