Service Sub Panel <br />OCTOBER 21, 2021 <br />PV SYSTEM <br />AS INDICATED <br />California Solar Group <br />Project Name Address Project Description Contractor <br />7647 Hayvenhurst Ave., Unit 26 <br />Van Nuys, CA 91406 <br />casolargroup.com <br />info@casolargroup.com <br />Phone Number: +1 818 658 2362 <br />Address & Phone Number <br />CSLB # 1067781 <br /> Drawn By: Unique Solar Design <br />SHEET SIZE <br />11''X 17'' ANSI B <br />SHEET NUMBER <br />Company Logo Signature <br />2210 W Avalon Ave <br />Santa Ana, CA 92706Abel Marica <br />5.10KW DC Roof Mounted <br />PV Electrical System <br />15-Hanwha 340W PV Modules <br />15-IQ7Plus Enphase Microinverters <br />Note <br />GENERAL NOTES: <br />T <br /> PVC/RMC/EMT Type Conduit <br />Main Service Panel <br />(N) Solar PV Module <br />Junction Box <br />INDEX <br />Solar Inverter <br />Power Optimizer / Microinverter <br />IQ Combiner Box <br />PV Load Center <br />Performance Meter <br />DC Disconnect <br /> FMT Type Conduit <br />(E) Solar PV Module <br />SHEET INDEX <br />TITLE PAGE <br />LINE DIAGRAM <br />CODE REQUIRED SIGNAGE <br />ATTACHMENT LAYOUT <br />INVERTER DATA SHEET <br />MODULE DATA SHEET <br />RACKING DATA SHEET <br />GROUNDING SPECS <br />ATTACHMENT DATA SHEET <br />SITE PLAN <br />PROJECT VICINITY MAP PROJECT SATELLITE VIEW <br />T <br />PV1 <br />PV2 <br />PV3 <br />PV4 <br />(E) Satellite <br />(E) Chimney <br />D1 <br />D2 <br />D3 <br />D4 <br />D5 <br />D6 <br />D7 <br />COMBINER BOX DATA SHEET <br />Setback Line <br />MSP <br />SSP <br />INV <br />DCD <br />J.B <br />IQB <br />PVLC <br />PM <br />(E) AC Unit <br />ALL ELECTRICAL WORK TO BE INSTALLED BY A QUALIFIED AND LICENSED <br />ELECTRICAL CONTRACTOR. <br />ALL SOLAR MODULES SHALL BE UL LISTED 1703 & CEC APPROVED. ALL <br />INVERTERS SHALL BE UL LISTED 1741 CERTIFIED & CEC APPROVED. ALL <br />ELECTRICAL COMPONENTS AND MATERIALS SHALL BE LISTED FOR IT'S <br />PURPOSE AND INSTALLED IN A WORKMAN LIKE MANNER. ALL OUTDOOR <br />EQUIPMENT SHALL MEET APPROPRIATE NEMA STANDARDS. <br />THE ELECTRICAL CONTRACTOR IS ADVISED THAT ALL DRAWINGS AND <br />COMPONENT MANUALS ARE TO BE UNDERSTOOD PRIOR TO INSTALLATION. <br />THE CONTRACTOR IS ADVISED TO HAVE ALL SWITCHES IN THE OFF POSITION <br />AND FUSES REMOVED PRIOR TO INSTALLATION OF FUSE-BEARING <br />COMPONENTS. <br />THIS SYSTEM IS INTENDED TO BE OPERATED IN PARALLEL WITH THE UTILITY <br />SERVICE PROVIDER. ANTI-ISLANDING PROTECTION IS A REQUIREMENT OF UL <br />1741 AND IS INTENDED TO PREVENT THE OPERATION OF THE PV SYSTEM <br />WHEN THE UTILITY GRID IS NOT OPERATIONAL. <br />PERMISSION TO OPERATE THE SYSTEM IS NOT AUTHORIZED UNTIL FINAL <br />INSPECTIONS AND APPROVALS ARE OBTAINED FROM THE LOCAL AUTHORITY <br />HAVING JURISDICTION AND THE LOCAL UTILITY SERVICE PROVIDER. <br />THE METHOD OF ATTACHMENT CREATES A UNIFIED STRUCTURE TO MEET <br />DEAD LOAD, WIND LOAD, AND SEISMIC REQUIREMENTS. SOLAR MODULES <br />WILL BE SECURED TO THE EXISTING ROOF AS SPECIFIED ON THE <br />STRUCTURAL SHEETS. EXISTING ROOF EQUIPMENT WILL NOT BE EFFECTED <br />BY THE PV SYSTEM. ALL STRUCTURAL DESIGN AND INSTALLATION <br />COMPONENTS ARE THE RESPONSIBILITY OF OTHERS AND OUTSIDE THE <br />SCOPE OF THIS DOCUMENT. <br />ALL FASTENERS SHALL BE CORROSION RESISTANT APPROPRIATE FOR SITE <br />CONDITIONS. CONNECTORS SHALL BE TORQUED PER DEVICE LISTING OR <br />ENGINEERING RECOMMENDATIONS. <br />ALL ROOFING REPAIR MUST MAINTAIN EXISTING CLASS AND TYPE OF ROOF <br />AND ALL WORK SHALL BE IN ACCORDANCE WITH THE ROOF IN <br />MANUFACTURER'S INSTALLATION REQUIREMENTS. <br />PROJECT DESCRIPTION: <br />SYSTEM SIZE: DC STC: 5.10 kW <br /> AC CEC: 4.64 kW <br />SOLAR MODULES: (15) HANWHA SOLAR 340W (Q.PEAK DUO BLK-G6 340) <br />INVERTER: (15) ENPHASE IQ7PLUS-72-2-US [240V] [SI1-JUN20] MICROINVERTERS <br />EXISTING MSP BUS: 200A <br />EXISTING MAIN BREAKER: 200A <br />NEW PV BREAKER: 30A <br />ONE STORY BUILDING <br />ROOF TYPE: COMPOSITION SHINGLE <br />ROOF STRUCTURE: 2''X4'' TRUSSES 24'' O/C <br />MOUNTING SYSTEM: IRONRIDGE RACKING <br />PARCEL NUMBER: 10158109 <br />LOT AREA: 8,300 SQFT <br />LIVING AREA: 2,031 SQFT <br />Visible Lockable Labeled DisconnectVLLD <br />APPLICABLE CODES <br />2019 CALIFORNIA ELECTRICAL CODE <br />2019 CALIFORNIA BUILDING CODE <br />2019 CALIFORNIA GREEN BUILDING STANDARDS CODE <br />2019 CALIFORNIA ENERGY CODE <br />2019 CALIFORNIA MECHANICAL CODE <br />2019 CALIFORNIA PLUMBING CODE <br />RACKING & MODULE CERTIFICATIONS <br />RACKING DETAILSD8 <br />N <br />Bldg# 101109038 <br />Elec# 20175063 <br />Issued 01/13/22