Laserfiche WebLink
Wire Tag Scope <br />#[23) CERTAINTEED -CT370HC11-66 <br />1 |(1)12-2TC-ER, THWN-2, COPPER,(OR CODE APPROVED EQUIVALENT), (1) 6 AWG BARE, COPPER (GROUND) <br />(23) ENPHASE IQ8M-72-2-US INVERTER(S) <br />2 | (2) 10 AWG THWN - 2, OR THHN, COPPER - (POSITIVE),(1) 10 AWG THWN - 2, OR THN, COPPER - (NEGATIVE},(1} 10 AWG THHN/THWN, COPPER -(GROUND),(1) 3/4°EMT cine 3 <br />3 _ | (@}OAWG THHN/THWN-2,COPPER -(L1), (3)10 AWG THHN/THWN-2,COPPER -(L2), (1) 10 AWG THHN/THWN-2 (GROUND), CONDUIT: 3/4" EMT String?8 <br />String3:7 <br />a |@) 8AWG THWN-2 COPPER - (L1), (1) 8 AWG THWN-2 COPPER (L2), (1) 8 AWG THWN-2 COPPER - (NEUTRAL), (1) 10 AWG THWN-2 COPPER - (GROUND}{1) CONDUIT: 3/4"EMT [ | String4:o <br />?Strings:0 <br />?Stringé:0 <br />CALCULATIONS: <br />PER CEC 690.80, "WHERE A SINGLE OVERCURRENT DEVICE IS USED TO PROTECT A SET OF TWO OR <br />MORE PARALLEL-CONNEGTED MODULE CIRCUITS, THE AMPACITY OF EACH OF THE MODULE <br />INTERCONNECTION CONDUCTORS SHALL NOT BE LESS THAN THE SUM OF THE RATING OF THE SINGLE <br />FUSE PLUS 125 PERCENT OF THE SHORT-CIRGUIT CURRENT FORM THE OTHER PARALLEL-GONNECTED <br />MODULES." <br />MODULE COUNT(23) * MIGROINVERTER MAX OUTPUT GURRENT(1.35) * (1.25) = 38.81A < 40A <br />THIS BREAKER MAY BE 10A OR 154 <br />AS PER MANUFACTURER, THIS <br />BREAKER ENERGIZES THE ENVOY (E) 200A MAIN SERVICE PANEL <br />(€)200A/2P MAIN BREAKER (6) UTILITY METER <br />ENPHASE IQ8M-72-2-US MICROINVERTER(S)(E)200A-2P <br />M e m o o u CIRCUIT (1):{N) 125A IQ COMBINER PV AC DISCONNECT8 MODULES VISIBLE, LOCKABLE, <br />C a s My LABELED, OPEN <br />={ \GOA, 240V, 2-POLE t?~| <br />|NDENVOY E) LOADS} <br />BRANCH CIRCUIT (2): B O X <br />V V 8 MODULES V V ( 1 )b a a <br />a s c M <br />f y N) 404-2P| <br />NEW <br />BRANCH CIRUIT (3):BOX A_|92082?¢T e . <br />V 7 MODULES.V M 1 2 e h | h y | J <br />PAPA a e }i a gl cot o r e s N <br />iG <br />BOX G <br />1 2 NEMA 3 3 JUNCTION BOX <br />EXISTING GROUNDING <br />ELECTRODE SYSTEM ? _ ? <br />I N T E R C O N N E C T I O N N O T E S : <br />1. I N T E R C O N N E C T I O N S I Z I N G , L I M I T A T I O N S A N D C O M P L I A N C E D E T E R M I N E D IN A C C O R D A N C E W I T H [ C E C 7 0 5 .1 2 }, A N D [ C E C 690.64]. <br />3. GROUND FAULT PROTECTION IN ACCORDANCE WITH [CEC 215.9], [CEC 230.95] AND [CEC 690.5] <br />4. ALL EQUIPMENT TO BE RATED FOR BACKFEEDING. <br />5. PV BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE BUSBAR RELATIVE TO THE MAIN BREAKER. <br />D I S C O N N E C T N O T E S <br />1. D I S C O N N E C T I N G S W I T C H E S S H A L L B E W I R E D S U C H T H A T W H E N T H E S W I T C H I S O P E N E D T H E C O N D U C T O R S R E M A I N I N G LI VE A R E <br />C O N N E C T E D T O T H E T E R M I N A L S M A R K E D ?LINE SIDE? ( T Y P I C A L L Y T H E U P P E R T E R M I N A L S ) <br />2. A C D I S C O N N E C T M U S T B E A C C E S S I B L E T O Q U A L I F I E D U T I L I T Y P E R S O N N E L , B E L O C K A B L E , A N D B E A V I S I B L E - B R E A K S W I T C H <br />VISIBLE, L O C K AB L E , <br />L A B E L E D AC D I S C O N N E C T <br />L O C A T E D WI THI N 10° <br />OF T H E UTILITY M E T E R <br />C o m p l e t e S o l a r <br />ABngrtes Way. <br />COMPLETE SOLAR <br />3000 EXECUTIVE PKWY.STE 504 <br />SAN RAMON, CA 94583 <br />LICENSE TYPE C10 <br />LICENSE # 961928 <br />PHONE# (877) 299-4943 <br />wey <br />C H A D H A <br />RISHI CHADHA PROIECT <br />2215 FREEMAN ST <br />SANTA ANA, CA 92705 <br />LAT , LONG: 33.7656184, <br />-117.8781931 <br />SITE I N F O R M A T I O N : <br />MAX CONTINUOUS AC SYSTEM SIZE: <br />DC SYSTEM SIZE: 8.51 kW <br />{23) CERTAINTEED - CT370HC11-06 <br />MODULES <br />(23) ENPHASE 1Q8M-72-2-US <br />INVERTER(S) <br />MOUNTING EQUIPMENT: <br />UNIRAC SM &UNIRAC- FLASHLOC <br />DESIGNED BY: BRAD NEWMAN <br />a C O M P L E T E <br />S O L A R <br />IDATE: J a n u a r y 27, 2 0 2 3 <br />L I NE D I A G R A M <br />PV-6.0 <br />2215 N Freeman St <br />02/21/23