My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2215 N Freeman St - Plan
PBA
>
Building
>
ProjectDox
>
F
>
Freeman St
>
2215 N Freeman St
>
2215 N Freeman St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2025 1:41:09 PM
Creation date
5/30/2025 8:00:52 AM
Metadata
Fields
Template:
Plan
Permit Number
20178299
101113265
101113912
Full Address
2215 N Freeman St
Document Relationships
101113265 - Permit
(Permit - Plan)
Path:
\Building\Permits\F\Freeman St\2215 N Freeman St
101113912 - Permit
(Permit - Plan)
Path:
\Building\Permits\F\Freeman St\2215 N Freeman St
20178299 - Permit
(Permit - Plan)
Path:
\Building\Permits\F\Freeman St\2215 N Freeman St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
4 asa otsantiago <br />ERVICW <br />weg @ <br />° <br />i <br />HY <br />nestfeoRAc PagK <br />ones snacanpect Fume?someantoe <br />woe Qiteaeree a wSe Sha <br />A E R I A L V I E W : <br />2295 Freeman $1 Page SANTIAGO] <br />Soeta ana GA 92700 <br />FaENCH COUR <br />wasmingtom <br />SHEET INDEX: <br />P y -1 .0 C O V E R S H E E T <br />PV-2.0 SITE PLAN <br />PV-3.0 ROOF PLAN <br />PV-4.0 ROOF ATTACHMENTS <br />PV-5.0 MOUNTING DETAIL <br />PV-6.0 LINE DIAGRAM <br />PV-7.0 LABELS <br />PY-8.0 P L A C A R D <br />G E N E R A L NOTES: <br />1, __ ALLELECTRICAL MATERIALS SHALL BE NEW AND LISTED BY RECOGNIZED ELECTRICAL <br />?TESTING LABORATORY CUSTOM MADE EQUIPMENT SHALL HAVE COMPLETE TEST DATA <br />SUBMITTED BY THE MANUFACTURER ATTESTING TO ITS SAFETY <br />2, OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED <br />3, ALLMETALLIC EQUIPMENT SHALL BE GROUNDED <br />4, ALL SPECIFIC WIRING {S BASEO ON THE USE OF COPPER. <br />§. _ CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS PRIOR TO INSTALLATION AND SHALL <br />COORDINATE ALL INSPECTIONS, TESTING COMMISSIONING AND ACCEPTANCE WITH THE CLIENT, <br />UTILITY CO. AND CITY INSPECTORS AS NEEDED. <br />6, THE ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS OF SERVICE POINTS <br />AND SERVICE SIZES WITH THE SERVING UTILITY COMPANY AND COMPLY WITH ALE UTILITY <br />COMPANIES REQUIREMENTS. IF THE SOLAR BACK FED BREAKER (S VOER THE BUSS SIZE 20% <br />LIMIT, CONTRACTOR SHALL INCLUDE THE COST TO REPLACE MAIN BREAKER OR ENLARGE MAIN <br />CAPACITY. <br />7.__ DRAWINGS ARE DIAGRAMMATIC ONLY. ROUTING OF RACEWAYS SHALL BE OPTION OF THE <br />CONTRACTOR UNLESS OTHERWISE NOTED AND SHALL BE COORDINATED WITH OTHER TRADES. <br />8, IF THE ROOF MATERIAL OR ROOF STRUCTURE NOT ADEGUATE FOR PV INSTALLATION, <br />CALL ENGINEER PRIOR TO INSTALL. THE CONTRACTOR IS RESPONSIBLE TO VERIFY THAT THE <br />ROOF 1S CAPABLE OF WITHSTANDING THE EXTRA WEIGHT <br />9. IF THE DISTANCES FOR CABLE RUNS ARE DIFFERENT THAN SHOWN, THE CONTRACTOR: <br />SHALL NOTIFY THE ELECTRICAL ENGINEER TO VALIDATE THE SIRE SIZE. FINAL DRAWINGS WILL <br />BE RED-LINED ANO UPDATED AS APPROPRIATE. <br />10. WHENEVER A DISCREPANCY IN QUALITY OF EQUIPMENT ARISES ON THE DRAWING OR <br />SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING <br />ALL MATERIAL AND SERVICES REQUIRED 8Y THE STRICTEST CONDITIONS NOTED ON THE <br />DRAWINGS OR IN THE SPECIFICATIONS TO ENSURE COMPLETE COMPLIANCE AND LONGEVITY OF <br />?THE OPERABLE SYSTEM REQUIRED BY THE ARCHITECTIENGINEERS. <br />11. ALL BROCHURES, OPERATION MANUALS, CATALOGS, SHOP DRAWINGS, ETC. SHALL BE <br />HANDED OVER TO OWNER'S REPRESENTATIVE AT THE COMPLETION OF WORK <br />?CHADrA RRRPROHECT <br />2295 FREEMAN ST <br />S A N T AAMA, CA92706 <br />AT,LONG 337656184, <br />GOV E R N I N G CODES: <br />THE INSTALLATION OF SOLAR ARRAY AND <br />PHOTOVOLTAIC POWER SYSTEMS SHALL <br />COMPLY WITH THE FOLLOWING CODES: <br />2019 CALIFORNIA ELECTRICAL CODE <br />2019 CALIFORNIA BUILDING CODE {VOL 1 & 2) <br />2019 CALIFORNIA RESIDENTIAL CODE <br />2019 CALIFORNIA FIRE CODE <br />2019 CALIFORNIA GREEN BUILDING STANDARDS CODE <br />2019 CALIFORNIA ENERGY CODE <br />2019 CALIFORNIA MECHANICAL CODE <br />A L L O T H E R O R D I N A N C E A D O P T E D B Y <br />T H E L O C A L G O V E R N I N G A G E N C I E S <br />117 2781851 <br />SCOPE OF WORK: <br />PV ROOF MOUNT INSTALLATION OF <br />23 CERTAINTEED - CT365HC11-06 MODULES, <br />23 ENPHASE 108M-72-2-US INVERTER(S), <br />EXISTING 200A MAIN SERVICE PANEL WITH 200A MAIN <br />?SITE INFORMATION: <br />METER CONNECTION: OVERHEAD <br />NO TRENCHING <br />S I T E S P E C I F I C A T I O N S : <br />Z O N I N G : R E S I D E N T I A L <br />O C C U P A N C Y G R O U P : R -3 <br />C O N S T R U C T I O N T Y P E : Y-B. <br />N U M B E R O F S T O R I E S : 1 <br />R O O F L A Y E R S : 1 <br />FIRE SPRINKLERS PRESENT: N <br />A H I : S A N T A A N A <br />SYSTEM I NFORM ATI ON: <br />DC SYSTEM SIZE: 8.4 KW <br />M AX CONTINUOUS A C SYSTEM SIZE: 7.48 kW <br />Signed 9/16/2022 <br />r o y C O M P L E T ! <br />S O L A R <br />CATE: September 18, 2022 <br />EQUIPMENT INFORMATION: <br />(23) CERTAINTEED - CT36SHC11-08 MODULES <br />(23) ENPHASE |Q8M-72-2-US INVERTER(S) <br />MOUNTING EQUIPMENT: UNIRAC SM & UNIRAC - FLASHLOC COMP - 72" 0.C. <br />C O V E R S H E E T <br />PV-1.0 <br />Bldg permit #101113265 <br />Elect permit #20178299 <br />Permits issued on 12/22/22 <br />2215 N Freeman St <br />12/27/22
The URL can be used to link to this page
Your browser does not support the video tag.