My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2230 N Tamy Ln - Plan
PBA
>
Building
>
ProjectDox
>
T
>
Tamy Ln
>
2230 N Tamy Ln
>
2230 N Tamy Ln - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2025 1:41:10 PM
Creation date
5/30/2025 8:00:52 AM
Metadata
Fields
Template:
Plan
Permit Number
20174662
101108445
Full Address
2230 N Tamy Ln
Document Relationships
101108445 - Permit
(Permit - Plan)
Path:
\Building\Permits\T\Tamy Ln\2230 N Tamy Ln
20174662 - Permit
(Permit - Plan)
Path:
\Building\Permits\T\Tamy Ln\2230 N Tamy Ln
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
A B <br />-- <br />IS <br />S <br />U <br />E <br />D <br /> <br />F <br />O <br />R <br />: <br /> <br />P <br />E <br />R <br />M <br />I <br />T <br />DA <br />T <br />E <br />: <br />So <br />l <br />a <br />r <br /> <br />P <br />h <br />o <br />t <br />o <br />v <br />o <br />l <br />t <br />a <br />i <br />c <br /> <br />S <br />y <br />s <br />t <br />e <br />m <br />9/ <br />3 <br />0 <br />/ <br />2 <br />0 <br />2 <br />1 <br />FI <br />D <br />E <br />L <br /> <br />Z <br />A <br />M <br />U <br />D <br />I <br />O <br />22 <br />3 <br />0 <br /> <br />T <br />A <br />M <br />Y <br /> <br />L <br />A <br />N <br />E <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />(7 <br />1 <br />4 <br />) <br /> <br />3 <br />4 <br />9 <br />- <br />1 <br />7 <br />4 <br />1 <br />SU <br />N <br />L <br />U <br />X <br />10 <br />8 <br />6 <br />0 <br /> <br />6 <br />T <br />H <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />RA <br />N <br />C <br />H <br />O <br /> <br />C <br />U <br />C <br />A <br />M <br />O <br />N <br />G <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />1 <br />7 <br />3 <br />0 <br />Ph <br />o <br />n <br />e <br />: <br /> <br />( <br />9 <br />0 <br />9 <br />) <br /> <br />3 <br />9 <br />0 <br />- <br />1 <br />7 <br />9 <br />6 <br />CS <br />L <br />B <br /> <br /># <br />1 <br />0 <br />0 <br />8 <br />3 <br />7 <br />4 <br /> <br />( <br />C <br />- <br />1 <br />0 <br />) <br />X_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />PV-4 <br />RE <br />Q <br />U <br />I <br />R <br />E <br />D <br /> <br />S <br />I <br />G <br />N <br />A <br />G <br />E <br /> ON THE FACE OF THE MAIN SERVICE <br />DISCONNECT PER CEC 690.13(B): <br />PV SYSTEM <br />DISCONNECT <br /> ON ALL INTERIOR AND EXTERIOR PV CONDUIT, <br />RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES <br />AND JUNCTION BOXES: <br />WARNING: PHOTOVOLTAIC POWER SOURCE <br />MARKING SHALL BE REFLECTIVE AND PLACED EVERY 10 <br />FEET AT TURNS AND ABOVE AND/OR BELOW <br />PENETRATIONS AND AT ALL PV COMBINER AND JUNCTION <br />BOXES. <br />THE FOLLOWING SIGNAGE MUST HAVE A MINIMUM <br />OF 3/8" HIGH LETTERING, IN ARIAL FONT <br />(NON-BOLD), WITH CAPITAL LETTERS, WHITE ON <br />RED BACKGROUND AND ON A REFLECTIVE, <br />WEATHER RESISTANT MATERIAL. <br />PLAQUES SHALL BE METAL OR PLASTIC WITH ENGRAVED <br />OR MACHINE PRINTED LETTERS, OR ELECTRO-PHOTO <br />PLATING, IN A CONTRASTING COLOR TO THE PLAQUE. <br />PLAQUE SHALL BE ATTACHED TO THE SERVICE <br />EQUIPMENT WITH APPROVED ADHESIVE. MINIMUM OF <br />3/8" HIGH WHITE LETTERING ON RED BACKGROUND. <br />ANY PHOTOVOLTAIC DC CONDUCTORS ENTERING THE <br />BUILDING SHALL BE INSTALLED IN A METALLIC RACEWAY <br />AND SHALL ALSO HAVE LABEL IDENTIFIED EVERY 10 FEET <br />- AND WITHIN 1 FOOT OF TURNS OR BENDS AND WITHIN 1 <br />FOOT ABOVE AND BELOW PENETRATIONS OF <br />ROOF/CEILING ASSEMBLIES, WALLS OR BARRIERS. <br /> ON FACE OF THE SERVICE METER PANEL: <br />SIGNAGE AT CONDUIT & BOXES: <br />SIGNAGE AT MAIN SERVICE PANEL: <br />1 <br />MSP1 <br />FRONT OF HOME <br />CAUTION <br />SERVICE POINT & <br />UTILITY METERING PV DISCONNECT <br />SOLAR ARRAY <br />YOU ARE <br />HERE <br /> MAP PLACARD ON FACE OF THE MAIN SERVICE PANEL <br />PER CEC 705.10: <br />MSP2 <br />MSP5 <br />MSP3 <br />MSP6 <br />TAMY LANE <br />MAXIMUM AC OPERATING CURRENT = 14.63A <br />MAXIMUM AC OPERATING VOLTAGE = 240V <br />2230 TAMY LANE <br />SANTA ANA, CA 92706 <br />RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM <br /> ON FACE OF THE SERVICE METER PANEL PER <br />CEC 690.56 (C)(1)(a): <br />SOLAR PV SYSTEM <br />EQUIPPED WITH RAPID SHUTDOWN <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE "OFF" <br />POSITION TO <br />SHUTDOWN PV SYSTEM <br />AND REDUCE SHOCK <br />HAZARD IN ARRAY <br />SOLAR PV SYSTEM IS EQUIPPED WITH RAPID <br />SHUTDOWN" SHALL UTILIZE CAPITALIZED <br />CHARACTERS WITH A MINIMUM HEIGHT OF 3/8" IN <br />BLACK ON YELLOW BACKGROUND, AND THE <br />REMAINING CHARACTERS SHALL BE CAPITALIZED <br />WITH A MINIMUM HEIGHT OF 3/16" IN BLACK ON WHITE <br />BACKGROUND. <br /> ON RAPID SHUTDOWN SWITCH LOCATED ON OR WITHIN <br />3' FROM SWITCH, IN 3 <br />8" LETTERS IN WHITE ON RED <br />BACKGROUND ON A REFLECTIVE LABEL PER CEC 690.56 <br />(C)(3): <br />MSP4 <br />WARNING <br />POWER SOURCE OUTPUT CONNECTION <br />DO NOT RELOCATE <br />THIS OVERCURRENT DEVICE <br />LOCATED AT BACKFED BREAKER PER CEC <br />705.12(B)(2)(3)(b): <br />MSP7 ON FACE OF THE SERVICE METER PANEL: <br />WARNING <br />DUAL POWER SUPPLY <br />SOURCES: UTILITY GRID AND PV SOLAR <br />ELECTRIC SYSTEM <br />2230 N Tamy Ln <br />11/01/21
The URL can be used to link to this page
Your browser does not support the video tag.