PROPOSED CEILING PLAN <br />SCALE 1/4" = 1'-0" <br />N <br />20'-4" <br />54 <br />' <br />- <br />1 <br />1 <br />" <br />24'-8" <br />J <br />8'-0" <br />9'-0" <br />54 <br />' <br />- <br />1 <br />1 <br />" <br />(E) COLUMN <br />(E) COLUMN <br />(N) <br /> EXISTING 2' X 4' FLUORESCENT LIGHT <br />EXISTING EXHAUSTED FAN 80 CFM <br />SYMBOLS: <br />ABBREVIATIONS: <br />(E) EXISTING <br />(N) NEW <br />@ AT <br />GALV. GALVANIZED <br />SHT. SHEET <br />FLEX. FLEXIBLE AIR DUCT <br />CLG. CEILING <br />CEILING HIGH <br />NEW 6" LED RECESSED FIXTURE <br />EXISTING ELECTRICAL PANEL <br />FIRE NOTE: <br />THE MEANS OF EGRESS TRAVEL, INCLUDING THE EXIT DISCHARGE, <br />SHALL BE ILLUMINATED AT ALL TIMES THE BUILDING SPACE SERVED <br />BY THE MEANS OF EGRESS IS OCCUPIED WITH A LIGHT INTENSITY <br />OF NOT LESS THAN 1 FOOT-CANDLE AT THE WALKING SURFACE <br />AS REQUIRED BY CALIFORNIA BUILDING CODE CHAPTER 10, <br />SECTIONS 1008.1 & 1008.2. <br />CEILING NOTES: <br />1. HEAVY-DUTY GRID SYSTEM REQUIRED. <br />2. MINIMUM 2-INCH WALL MOLDING REQUIRED. <br />3. LIGHT FIXTURES MUST BE POSITIVELY ATTACHED TO THE SUSPENDED SYSTEM. <br />ATTACHED DEVICE MUST BE ABLE TO WITHSTAND 100% OF THE FIXTURE WEIGHT. <br />4.IF LIGHT FIXTURE IS 56 POUNDS OR LESS, MUST HAVE TWO 12-GAUGE WIRES ATTACHED <br />AT DIAGONAL CORNERS. IF MORE THAN 56 POUNDS, MUST BE INDEPENDENTLY <br />SUPPORTED FROM THE BUILDING STRUCTURE. <br />5. ALL HANGER WIRE SHALL BE 12 GALV. WIRE OR CODE- APPROVED EQUAL. <br />6. ALL HANGER AND RUNNERS SHALL BE ACCURATELY LEVELED AND BE SPACED IN <br />ACCORDANCE WITH MANUF. SPECS. <br />7. ALL INTERSECTIONS AND CONNECTION ACCESSORIES THROUGHOUT SHALL BE <br />CAPABLE OF WITHSTANDING DESIGN LOADS REQUIRED BY LOCAL CODES. <br />8.AT LIGHT FIXTURES PROVIDE 12 GALV. WIRE AT DIGONAL OPPOSED AND SHALL BE <br />PAINTED RED. <br />9'-0" <br />L EXISTING 2'WRAP FLOUR. LIGHT <br />EXISTING FIRE SPRINKLER <br />(E) (E) <br />(E) (E) <br />(E) <br />(E) <br />(E) (E) <br />(E)(E) <br />DRY WALL CLG.(E) <br />(N) (N)(N) (N) <br />(N)(N) (N) (N) <br />(N) (N) <br />3' <br />5' <br />- <br />6 <br />" <br />3' <br />3' <br />6' <br />(E) <br />9'-0" <br />9'-0" <br />5' <br />- <br />6 <br />" <br />EXISTING CEILING PLAN <br />SCALE 1/4" = 1'-0" <br />N <br />20'-4" <br />54 <br />' <br />- <br />1 <br />1 <br />" <br />24'-8" <br />J <br />8'-0" <br />54 <br />' <br />- <br />1 <br />1 <br />" <br />(E) COLUMN <br />(E) COLUMN <br />(E) (E) <br />(E) (E) <br />(E) <br />(E) <br />(E) (E) <br />(E) (E) <br />(E) <br />DRY WALL CLG.(E) <br />(E) <br />9'-0" <br />(E) (E) <br />(E) <br />(E) (E) <br />(E)(E)(E) <br />(E) (E) <br />(E) <br />(E) <br />(E) (E) <br />(E) <br />(E) <br />NEW EXIT SIGN WITH EMERGENCY LIGHTS <br />WAITING AREA <br />KITCHEN <br />STORAGE <br />(E) <br />(E) <br />(E) (E) <br />(E) <br />(E)(E) <br />(E) <br />(E) <br />(E) (E) <br />(E) <br />(E) (E) <br />19'-4" <br />A A <br />B <br />NOTES: <br />TWO LVL 1.75 X 7.25 <br />TWO LVL 1.75 X 7.25TW <br />O <br /> <br />2 <br /> <br />X <br /> <br />8 <br />TW <br />O <br /> <br />2 <br /> <br />X <br /> <br />8 <br />2 X 8 <br />LVL 1.75 X 7.25 <br />LVL 1.75 X 7.25 <br />LVL 1.75 X 7.25 <br />LVL 1.75 X 7.25 <br />LVL 1.75 X 7.25 <br />2 X 8 <br />(E) <br />(E) <br />(E) <br />(E) <br />(E) <br />(E) <br />(E) <br />(E) <br />(E) <br />36 <br />' <br />- <br />1 <br />1 <br />" <br />29 <br />' <br />- <br />5 <br />" <br />4' <br />(E) <br />(E) <br />(E) <br />(E) <br />9. (E) T-BAR CEILING MATERIAL: USG SHEETROCK BRAND LAY-IN CEILING PANES. <br />the horizontal ceilings should be flashed to the roof, and painted semi-gross.B <br />7-23-2021 <br />2021-164483 <br />08/24/21