My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2305 W Huckleberry Rd - Plan
PBA
>
Building
>
ProjectDox
>
H
>
Huckleberry Rd
>
2305 W Huckleberry Rd
>
2305 W Huckleberry Rd - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2025 4:53:30 PM
Creation date
5/30/2025 8:00:53 AM
Metadata
Fields
Template:
Plan
Permit Number
20175933
101110115
Full Address
2305 W Huckleberry Rd
Document Relationships
101110115 - Permit
(Permit - Plan)
Path:
\Building\Permits\H\Huckleberry Rd\2305 W Huckleberry Rd
20175933 - Permit
(Permit - Plan)
Path:
\Building\Permits\H\Huckleberry Rd\2305 W Huckleberry Rd
Stamp
ID:
1
Creator:
Import Agent
Created:
5/30/2025 4:48 PM
Modified:
5/30/2025 8:44 AM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
STRUCTURAL ANALYSIS FOR NEW PHOTOVOLTAIC SOLAR SYSTEM <br />NOTE: <br />THESE CALCULATIONS ARE BASED ON INFORMATION AND MEASUREMENTS PROVIDED BY THE CONTRACTOR FROM <br />HIS SITE INSPECTION. <br />1 Project Information:PV SOLAR ARRAY: PHAM RESIDENCE <br />Latitude 33.7635° deg N 2305 HUCKLEBERRY ROAD, SANTA ANA, CA 92706 <br />Longitude -117.901° deg W <br />Wind Speed 110 mph 89 mph (ASCE 7-16) <br />Wind Exposure C <br />Site Class D <br />Seismic Design Category D <br />2 Loads: <br />Existing Roof Dead Loads: <br />2 x 6 Rafters @ 16" OC 1.5 psf <br />1/2" Roof Sheathing 1.7 psf <br />Roof Felt 1.5 psf <br />Tile 12.0 psf <br />Miscellaneous 3.3 psf <br />Total 20.0 psf <br />Existing Snow Load:0.0 psf <br />Existing Roof Live Load:20.0 psf <br />Proposed Roof Live Load:20.0 psf <br />Wind Load: Using CBC 2019 (ASCE 7-16), Chapter 29: Wind Loads on Rooftop Equipment, the <br />following wind pressures were calculated. <br />p = qh (GCp) (ge) (ga) = 10.15 -52.22 psf <br />qh = 0.00256 Kz Kzt Kd Ke V2 = 21.76 psf <br />Kz = 0.85 (0-15 = 0.85, 20 = 0.90, 25 = 0.94, 30 = 0.98, 40 = 1.04) <br />GCp = 0.7 -3.6 (Roof pitch = 18 deg, Zone = 2, Aeff = 18.0 sf) <br />ge = 1.50 <br />ga = 0.80 <br />Lag Bolt Capacity: <br />5/16" lag bolt capacity = 270 lbs per inch embedment <br />With 2 1/2" minimum embedment, capacity = 675 lbs <br />Required Capacity: <br />52.22 psf * 23 modules * 18.0 sf = 21620.7 lbs <br />21620.7 lbs / 64 lag bolt connections = 337.8 lbs <br />The pull-out capacity of the 5/16" lag bolts with a minimum 2 1/2" embedment into the roof rafter is sufficient <br />to meet the demand of the wind uplift force on the solar system. <br />Seismic Load: Per the CEBC 2019 Section 503.4, if the demand-capacity ratio of the lateral load-carrying <br />elements increases less than 10% due to the addition of the solar system, no special provisions or structural <br />modifications are required. <br />Existing Roof Weight = 20.0 psf * 1905 sf = 38100 lbs <br />Weight of Solar System = 23 modules * 42.9 lbs + 207 lbs of racking = 1194 lbs <br />1194 lbs / 38100 lbs = 0.03 <br />The increase in load from the solar system will not increase the demand-capacity ratio of the existing lateral <br />load-carrying elements by over 10%. <br />NOTICE:VISION CIVIL ENGINEERING: JENNIFER KEMME, PE <br />ANY CHANGES TO OR USES OF THESE DOCUMENTS 12273 11TH STREET, YUCAIPA, CA 92399 <br />WITHOUT THE WRITTEN CONSENT OF VISION 909.754.8300, JENKEMME@VISIONCE.COM <br />CIVIL ENGINEERING IS STRICTLY PROHIBITED.RCE 73054, EXP 12/31/22 <br />Prepared by JENNIFER KEMME 3/22/2022 Page 1
The URL can be used to link to this page
Your browser does not support the video tag.