Laserfiche WebLink
HOMEOWNER: SANG PHAM <br />PH: 714.616.6620 <br />ADDRESS: 2305 HUCKLEBERRY ROAD <br />SANTA ANA, CA 92706 <br />DATE: 3/14/22DATE: 3/14/22 <br />ECOSOLAR USA <br />ELECTRICAL LLC <br />13962 SEABOARD CIRCLE <br />GARDEN GROVE, CA 92840 <br />PH: 714.265.9077 DAVID Q HOANG C10 - 1045300 <br />SCO3E O) :OR. <br />INSTALL (23) SUNPOWER SPR-X22-360-E-AC SOLAR <br />ELECTRIC MODULES ON THE EXISTING 2ND STORY <br />TILE ROOF. INSTALL ASSOCIATED MOUNTING <br />HARDWARE, JUNCTION BOXES, CONDUIT, <br />CONDUCTORS AND GROUNDING. INSTALL (1) LOAD <br />CENTER, AND INSTALL OCPD IN SUB PANEL. <br />9ICI1 IT< 0A3 <br />PHAM <br />RESIDENCE <br />S+EET I1'E; <br />SHEET 1 PROJECT INFO, VICINITY MAP, NOTES, SCOPE OF WORK <br />SHEET 2 SITE/ROOF PLAN, ELEVATION DETAIL <br />SHEET 3 ELECTRIC LINE DRAWING, GROUNDING DETAIL <br />SHEET 4 CALCULATIONS, SIGNS <br />ATTACHED MODULE, INVERTER, MOUNTING HARDWARE SPEC SHEETS, <br />STRUCTURAL REPORT <br />NTS <br />S+EET <br />1OTICE <br />A1 < C+A1*ES TO OR USES O ) T+ESE 'OCU0E1TS'RA:I1*S :IT+OUT T+E <br />:RITTE1 CO1SE1T O) -E11I)ER .E00E OR SCOTT +ARRIS ARE STRICTL< 3RO+I%ITE' <br /> O)  <br />PLANS PREPARED BY: <br />JENNIFER KEMME <br />PH: 909.748.1300 <br />(23) SUNPOWER SPR-X22-360-E-AC <br />AC MODULES <br />PEAK POWER = 360 W <br />MAX OUTPUT CURRENT = 1.31 A <br />MAX OCPD = 20 A <br />MAX NUMBER IN SERIES = 12 <br />TEMP. COEFF. OF POWER = -0.29%/°C <br />DIMENSIONS = 61.3" X 41.2" X 1.8" <br />WEIGHT = 42.9 LBS <br />*E1ERAL 1OTES <br />1. THIS SYSTEM COMPLIES WITH THE 2019 CRC, 2019 CBC, 2019 CFC, AND THE 2019 <br />CEC. <br />2. THE SYSTEM WILL NOT BE TURNED-ON UNTIL THE SERVING UTILITY COMPANY <br />HAS BEEN NOTIFIED. <br />3. THE INSTALLED SOLAR SYSTEM HAS A DISTRIBUTED WEIGHT LESS THAN 4 PSF. <br />4. THE CONCENTRATED LOAD FOR EACH VERTICAL SUPPORT IS LESS THAN 40 LBS. <br />5. ALL PV EQUIPMENT IS LISTED BY A RECOGNIZED TESTING LAB. INVERTERS ARE <br />UL 1741 COMPLIANT. <br />6. THE BACKFED BREAKER WILL BE LOCATED AT THE OPPOSITE END OF THE BUS <br />FROM THE MAIN BREAKER. <br />7. CONDUCTORS ARE 90° C RATED COPPER WIRE. <br />8. ANY CONDUCTORS EXPOSED TO SUNLIGHT ARE LISTED AS SUNLIGHT <br />RESISTANT. <br />9. IF DC CONDUCTORS ARE RUN INSIDE THE BUILDING, THEY WILL BE CONTAINED <br />IN A METAL RACEWAY. <br />10. ANY CONDUCTORS BETWEEN SEPARATE ARRAYS ON THE ROOF WILL BE <br />PROTECTED IN CONDUIT. <br />11. THE EQUIPMENT GROUNDING CONDUCTOR ON THE ROOF WILL BE PROTECTED <br />FROM PHYSICAL DAMAGE. IT WILL BE TUCKED NEATLY UNDER THE MODULES <br />AND RAILS AND SECURED IN PLACE. <br />12. THE MODULES WILL BE ATTACHED TO THE EQUIPMENT GROUNDING <br />CONDUCTOR IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. <br />13. ALL EXTERIOR CONDUIT, FITTINGS AND BOXES ARE RAIN-TIGHT AND APPROVED <br />FOR USE IN WET LOCATIONS. <br />14. CLEARANCES AROUND ALL ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN <br />ACCORDANCE WITH CEC 110.26. <br />15. SOLAR MODULES WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL OR <br />BUILDING ROOF VENTS. <br />16. IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE <br />GROUNDING ELECTRODE SYSTEM, A GROUNDING ELECTRODE SYSTEM WILL BE <br />INSTALLED PER CEC 250.50. THE ELECTRICAL SERVICE WILL BE BONDED TO THE <br />WATER AND GAS PIPING PER SECTION 250.104 OF THE CEC. <br />17. A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH CAL-OSHA <br />REGULATIONS. <br />88999PV <br />3+OTO9OLTAIC SOLAR 3RO-ECT I1)OR0ATIO1 <br />SYSTEM SIZE: 8.280 kW (DC) <br />MODULES: <br />ARRAY:INSTALLED WEIGHT = 2.9 PSF <br />ROOF COVERAGE = 405 SF, <br />LESS THAN 50% OF TOTAL ROOF AREA <br />MOUNTING HARDWARE: SUNPOWER INVISIMOUNT RAIL <br />UNIRAC TILE HOOK ATTACHMENTS <br />5 16" STAINLESS STEEL LAG BOLTS @ <br />64" OC OR LESS WITH A MINIMUM OF <br />21 2" PENETRATION INTO ROOF RAFTERS <br />EXISTING ROOF INFO: 2 STORY, CONCRETE W TILE <br />2 X 6 RAFTERS @ 16" OC <br />BLDG# 101110115 <br />ELEC# 20175933 <br />ISSUED 04/15/22