My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2319 N Flower St - Plan
PBA
>
Building
>
ProjectDox
>
F
>
Flower St
>
2319 N Flower St
>
2319 N Flower St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2025 1:41:11 PM
Creation date
5/30/2025 8:00:53 AM
Metadata
Fields
Template:
Plan
Permit Number
20176065
101110288
Full Address
2319 N Flower St
Document Relationships
101110288 - Permit
(Permit - Plan)
Path:
\Building\Permits\F\Flower St\2319 N Flower St
20176065 - Permit
(Permit - Plan)
Path:
\Building\Permits\F\Flower St\2319 N Flower St
Text box
ID:
1
Creator:
Import Agent
Created:
5/30/2025 10:00 AM
Modified:
5/30/2025 8:47 AM
Text:
https://enphase.com/en-us/support/module-compatibility
ID:
2
Creator:
Import Agent
Created:
5/30/2025 10:00 AM
Modified:
5/30/2025 8:47 AM
Text:
http://www.enphase.com
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
1. No enforced DC/AC ratio. See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility. <br />2. CEC peak power tracking voltage range is 38 V to 43 V. <br />3. Maximum continuous input DC current is 10.2A. <br />4. Voltage range can be extended beyond nominal if required by the utility. <br />5. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. <br />To learn more about Enphase offerings, visit enphase.com <br />© 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, Enphase IQ 7A, Enphase IQ Battery, Enphase Enlighten, Enphase IQ <br />Envoy, and other trademarks or service names are the trademarks of Enphase Energy, Inc. Data subject to change. <br />11-04-2021 <br />INPUT (DC) IQ7A-72-2-US <br />Commonly used module pairings¹ 295 W–460 W + <br />Module compatibility 60-cell, 66-cell and 72-cell PV modules <br />Maximum input DC voltage 58 V <br />Power point tracking voltage range² 18 V–58 V <br />Min/Max start voltage 33 V / 58 V <br />Max DC short circuit current (module Isc)³ 15 A <br />Overvoltage class DC port II <br />DC port backfeed current 0 A <br />PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; <br />AC side protection requires max 20A per branch circuit <br />OUTPUT (AC) @ 240 VAC @ 208 VAC <br />Peak output power 366 VA 295 VA <br />Maximum continuous output power 349 VA 290 VA <br />Nominal (L-L) voltage/range4 240 V / 211–264 V 208 V / 183–229 V <br />Maximum continuous output current 1.45 A (240 VAC) 1.39 A (208 VAC) <br />Nominal frequency 60 Hz <br />Extended frequency range 47–68 Hz <br />AC short circuit fault current over 3 cycles 5.8 Arms <br />Maximum units per 20 A (L-L) branch circuit5 11 (240 VAC)11 (208 VAC) <br />Overvoltage class AC port III <br />AC port backfeed current 18 mA <br />Power factor setting 1.0 <br />Power factor (adjustable) 0.85 leading ... 0.85 lagging <br />EFFICIENCY @240 VAC @208 VAC <br />CEC weighted efficiency 97.0 % 96.5% <br />MECHANICAL <br />Ambient temperature range -40ºC to +60ºC <br />Relative humidity range 4% to 100% (condensing) <br />Connector type: DC (IQ7A-72-2-US) MC4 <br />Dimensions (HxWxD) 212 mm x 175 mm x 30.2 mm (without bracket) <br />Weight 1.08 kg (2.38 lbs) <br />Cooling Natural convection — No fans <br />Approved for wet locations Yes <br />Pollution degree PD3 <br />Enclosure Class II double-insulated, corrosion resistant polymeric enclosure <br />Environmental category / UV exposure rating NEMA Type 6 / outdoor <br />FEATURES <br />Communication Power Line Communication (PLC) <br />Monitoring Enlighten Manager and MyEnlighten monitoring options <br />Compatible with Enphase IQ Envoy <br />Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break <br />disconnect required by NEC 690. <br />Compliance CA Rule 21 (UL 1741-SA) <br />UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, <br />CAN/CSA-C22.2 NO. 107.1-01 <br />This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC <br />2017, and NEC 2020, section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, <br />for AC and DC conductors, when installed according manufacturer’s instructions. <br />Enphase IQ 7A Microinverter <br />2319 N Flower <br />05/17/22
The URL can be used to link to this page
Your browser does not support the video tag.