My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2321 S Rene Dr - Plan
PBA
>
Building
>
ProjectDox
>
R
>
Rene Dr
>
2321 S Rene Dr
>
2321 S Rene Dr - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2025 4:53:29 PM
Creation date
5/30/2025 8:00:53 AM
Metadata
Fields
Template:
Plan
Permit Number
20178435
101113476
Full Address
2321 S Rene Dr
Document Relationships
101113476 - Permit
(Permit - Plan)
Path:
\Building\Permits\R\Rene Dr\2321 S Rene Dr
20178435 - Permit
(Permit - Plan)
Path:
\Building\Permits\R\Rene Dr\2321 S Rene Dr
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Page 2 of 2 <br />D. Solar Panel Anchorage <br />1. The solar panels shall be mounted in accordance with the most recent EcoFasten installation <br />manual. If during solar panel installation, the roof framing members appear unstable or deflect non - <br />uniformly, our office should be notified before proceeding with the installation. <br />2. The maximum allowable withdrawal force for a 5/16” lag screw is 235 lbs per inch of penetration as <br />identified in the National Design Standards (NDS) of timber construction specifications. Based on <br />a minimum penetration depth of 2½”, the allowable capacity per connection is greater than the <br />design withdrawal force (demand). Considering the variable factors for the existing roof framing <br />and installation tolerances, the connection using one 5/16” diameter lag screw with a minimum of <br />2½” embedment will be adequate and will include a sufficient factor of safety. <br />3. Considering the wind speed, roof slopes, size and spacing of framing members, and condition of <br />the roof, the panel supports shall be placed no greater than 48” on centers. <br />4. Panel supports connections shall be staggered to distribute load to adjacent framing members. <br />Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing <br />roof system will adequately support the additional loading imposed by the solar system. This evaluation is in <br />conformance with the 2019 California Building Code, current industry standards, and is based on information <br />supplied to us at the time of this report. <br />Should you have any questions regarding the above or if you require further information do not hesitate to <br />contact me. <br />Very truly yours, <br /> <br /> <br />Scott E. Wyssling, PE <br />California License No. 83664 <br />2321 S Rene Dr <br />01/25/23
The URL can be used to link to this page
Your browser does not support the video tag.