Laserfiche WebLink
Ow <br />n <br />e <br />r <br />Ma <br />n <br />u <br />a <br />l <br /> <br />O <br />r <br />e <br />n <br />d <br />a <br />i <br />n <br />23 <br />3 <br />3 <br /> <br />E <br />v <br />e <br />r <br />g <br />r <br />e <br />e <br />n <br /> <br />S <br />t <br />Sa <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />32 <br />3 <br />- <br />2 <br />4 <br />4 <br />- <br />5 <br />8 <br />8 <br />8 <br />Ex <br />i <br />s <br />t <br />i <br />n <br />g <br /> <br />S <br />i <br />n <br />g <br />l <br />e <br /> <br />F <br />a <br />m <br />i <br />l <br />y <br /> <br />R <br />e <br />s <br />i <br />d <br />e <br />n <br />c <br />e <br />Drafted By <br />San Diego Solar Permits <br />www.sandiegosolarpermits.com <br />P.O. Box 9755 <br />San Diego, CA 92169 <br />(619) 289-8997 <br />PV-04 <br />Pl <br />a <br />n <br />s <br /> <br />A <br />p <br />p <br />r <br />o <br />v <br />e <br />d <br /> <br />B <br />y <br />Co <br />n <br />t <br />r <br />a <br />c <br />t <br />o <br />r <br />Lo <br />t <br />t <br />a <br /> <br />E <br />l <br />e <br />c <br />t <br />r <br />i <br />c <br /> <br />I <br />n <br />c <br />1 <br />0 <br />1 <br />3 <br />7 <br /> <br />P <br />i <br />n <br />e <br />w <br />o <br />o <br />d <br /> <br />V <br />i <br />e <br />w <br />Sa <br />n <br />t <br />e <br />e <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />0 <br />7 <br />1 <br />(6 <br />1 <br />9 <br />) <br /> <br />4 <br />5 <br />7 <br />- <br />3 <br />8 <br />1 <br />3 <br />Co <br />n <br />t <br />r <br />a <br />c <br />t <br />o <br />r <br /> <br />L <br />i <br />c <br />. <br /> <br /># <br />1 <br />0 <br />7 <br />3 <br />7 <br />4 <br />1 <br />, <br /> <br />C <br />1 <br />0 <br />An <br />t <br />h <br />o <br />n <br />y <br /> <br />L <br />o <br />t <br />t <br />a <br />Li <br />c <br />. <br /> <br /># <br />1 <br />0 <br />7 <br />3 <br />7 <br />4 <br />1 <br /> <br />C <br />1 <br />0 <br />1. IronRidge XR10 Rail Racking System with Integrated Grounding <br />2. IronRidge FlashFoot2 Mounts & Flashings <br />3. Racking loading calculations were performed for ASCE 7-16 wind speeds @ 100 mph for B <br />wind exposure category. <br />4. Roof attachment hardware to be mounted to existing structure - 2”X4”@24" O.C. RAFTERS <br />at 72“ O.C. RAIL SPANS or less. <br />5. Lag bolts are 5/16” X 4.75” stainless steel with 2.5” minimum embedment into the roof rafters. <br />6. Roof sheathed with ½” plywood and upper surface is faced with felt paper. Finished roof <br />surface is COMPOSITE SHINGLE. <br />7. Lag screws shall be at least 6 inches from any truss joints. <br />8. Mounts or/and mounting hardware will be sealed with Tremco Vulkem 116 Polyurethane <br />Sealant or equivalent. <br />Roof Load Calculation for Flush Mounted Panels <br />Flush Mount Detail <br />Module Weight (lbs)43 <br /># of Modules 11 <br />Total Module Weight (lbs)473 <br />Rack Weight (lbs)74.4 <br />Total System Weight (lbs)547.4 <br /># of Standoffs 24 <br />Max Spans between Standoffs (in)72 <br />Loading per Standoff (lbs)22.81 <br />Total Area (sq. ft.)216.3 <br />Loading (PSF)2.53 <br />MOUNTING DETAIL: <br />24” O.C. <br />24” O.C. <br />Existing Roof Structure <br />Existing Roof Structure <br />Attachment Span Max 72” OC <br />Attachement Span Max 72” OC <br />5/16" x 4.75" STAINLESS STEEL <br />LAG BOLT WITH 2 1/2" MIN <br />THREAD PENETRATION <br />ALUMINUM PV FLASHING <br />MODULE MOUNTING CLIP <br />SOLAR MODULE <br />ALUMINUM SUPPORT RAIL <br />ALUMINUM CAP <br />COMPOSITION ROOF <br />EXISTING ROOF STRUCTURE <br />MA <br />X <br /> <br />HEIG <br />H <br />T <br /> <br />5” <br /> <br />This item has been digitally signed <br />and sealed on Aug 29, 2022 <br />2333 Evergreen St <br />- 2017743510/04/22