Laserfiche WebLink
MOUNTING DETAILS <br />S-1.0 <br />CUSTOMER INFORMATION <br />NAME&ADDRESS: <br />APN:001-054-01 <br />AHJ:CA-CITY OF SANTA ANA <br />UTILITY:SCE <br />SYSTEM INFORMATION <br />DESIGNER/CHECKED BY: <br />RA/MR <br />PROJECT NUMBER:BVIS-006984 <br />SCALE:AS NOTED PAPER SIZE:17"x11" <br />JUAN HERNANDEZ <br />2422 N PACIFIC AVE, SANTA ANA, CA 92706. <br />ENGINEER OF RECORD <br />DATE:8/25/2022 REV:A <br />DC SYSTEM SIZE: 4810W <br />AC SYSTEM SIZE: 3770W <br />CEC AC SYSTEM SIZE: 4360W <br />MODULES: <br />(13)CERTAINTEED SOLAR CT370HC11-06 <br />INVERTER: <br />(13)ENPHASE IQ7PLUS-72-2-US(240V,1PH) <br />BRANCH DETAILS: <br />1 BRANCH OF 13 MICRO INVERTERS (13 MODULES) <br />7867 DUNBROOK RD SUITE D, SAN DIEGO, <br />CA 92126. <br />TEL:(559)930-7163 <br />LIC:#C46@1033754 <br />CONTRACTOR INFORMATION <br />S-1.0 <br />B MOUNTING DETAILS <br />SCALE: 3/32" = 1'-0" <br />UPLIFT CALCULATIONS <br />UPLIFT 7654.3 LBS <br />PULL OUT STRENGTH 13530 LBS <br />POINT LOADING 27 LBS <br />MODULES DATA <br />CERTAINTEED SOLAR CT370HC11-06 <br />MODULE DIMS 69.1"x40.9"x1.37" <br />LAG SCREWS 5/16"x3":2.5"MIN EMBEDMENT <br />AERIAL VIEW <br />SITE INFORMATION <br />SR.NO AZIMUTH PITCH NO. OF <br />MODULES <br />ARRAY AREA <br />(SQ. FT.)ROOF TYPE ATTACHMENT ROOF <br />EXPOSURE FRAME TYPE FRAME <br />SIZE <br />FRAME <br />SPACING <br />MAX RAIL <br />SPAN <br />OVER <br />HANG <br />MP-01 270 23 9 176.6 COMPOSITION <br />SHINGLE UNIRAC FLASHLOC ATTIC RAFTERS 2 X 4 2'-0"6'-0" 2'-0" <br />MP-02 180 23 4 78.5 COMPOSITION <br />SHINGLE UNIRAC FLASHLOC ATTIC RAFTERS 2 X 4 2'-0"6'-0" 2'-0" <br />MINIMUM FIRE ACCESS PATHWAYS PER CFC 2019 <br />RIDGE TO ARRAY: 1'-6" <br />EAVE TO ARRAY : 3'-0" <br />HIP/VALLEY W/ ADJACENT ARRAY: 1'-6" <br />EACH SIDE HIP/VALLEY W/O ADJACENT ARRAY: 0'-0" <br />NOTE: INSTALLER TO VERIFY RAFTER SIZE, SPACING AND SLOPED <br />SPANS, AND NOTIFY ANY DISCREPANCIES BEFORE PROCEEDING. <br />FIRE SETBACK <br />DEAD LOAD CALCULATIONS <br />BOM QUANTITY LBS/UNIT TOTAL <br />WEIGHT (LBS) <br />MODULES 13 45.19 587.47 <br />MID-CLAMP 20 0.050 1.00 <br />END-CLAMP 12 0.050 0.60 <br />RAIL LENGTH 91 0.680 61.88 <br />SPLICE BAR 6 0.360 2.16 <br />UNIRAC FLASHLOC 22 1.47 32.34 <br />MICRO-INVERTER 13 2.38 30.94 <br />TOTAL WEIGHT OF THE SYSTEM (LBS)716.39 <br />TOTAL ARRAY AREA ON THE ROOF (SQ. FT.)255.14 <br />WEIGHT PER SQ. FT.(LBS)2.81 <br />WEIGHT PER PENETRATION (LBS)32.56 <br />3' <br />1' <br />- <br />6 <br />" <br />6' <br />ARRAY MP-01 <br />ALUMINIUM RAILS <br />2 X 4 RAFTERS@ 2'-0" SPACING <br />ARRAY MP-02 <br />3' <br />9-23 <br />2422 N Pacific Ave <br />10/07/22