Laserfiche WebLink
REV <br />SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />ANSI B <br />11" X 17" <br />DATE DESCRIPTION <br />REVISIONS <br />Signature with Seal <br />PROJECT NAME & ADDRESS <br />PV-5 <br />PROJECT ID <br />JO <br />R <br />G <br />E <br /> <br />L <br />O <br />P <br />E <br />Z <br />25 <br />3 <br />0 <br /> <br />N <br /> <br />P <br />A <br />C <br />I <br />F <br />I <br />C <br /> <br />A <br />V <br />E <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />, <br />U <br />S <br />A <br />FRESH09/13/2021 ORIGINAL PLAN <br />2065 W OBISPO AVE #102 <br />GILBERT, AZ 85233 USA <br />866-572-2637 <br />LIC # CA-1019100 <br />ABHISHEK MAHESH <br />KABILAN SELVARANGAN <br />A08/09/2022 REV <br />B08/12/2022 REV <br />ELECTRICAL LINE <br />DIAGRAM <br />MAIN SERVICE VOLTAGE: <br />MAIN PANEL BRAND: <br />MAIN SERVICE PANEL: <br />MAIN BREAKER RATING: <br />MAIN SERVICE LOCATION: <br />SERVICE FEED SOURCE: <br />240V <br />100 A (EXISTING) <br />NORTH-EAST <br />(11 ) LONGI SOLAR LR4-60HPB 355M 355W MODULES <br />(01) SOLAREDGE TECHNOLOGY:SE3800H-US (240V) <br />(11) SOLAREDGE POWER OPTIMIZER P-401 <br />(1) STRING OF 11 MODULES CONNECTED IN SERIES. <br />SCALE: NTSPV-5 <br />1 ELECTRICAL LINE DIAGRAM <br />Tag # <br />THWN-2 - Ground <br />Conduit Conductor Schedule (ALL CONDUCTORS MUST BE COPPER) <br />THWN-2 <br />1 <br />1 <br />2 <br />2 <br />3 <br />Bare Copper Ground (EGC/GEC) <br />THWN-2 <br />PV WIRE <br />10 AWG <br />8 AWG <br />THWN-2 - Ground <br />Description Wire Gauge # of Conductors/Color <br />10 AWG <br />6 AWG <br />10 AWG <br />8 AWG <br />2 (1V+, 1V-) <br />1 BARE <br />2 (1V+, 1V-) B/R <br />1 (GRN) <br />3 (1L1, 1L2, 1N) B/R/W <br />1 (GRN)3 <br />INTERCONNECTION <br />120% RULE - NEC 705.12(B)(2)(3)(a) <br />UTILITY FEED + SOLAR BACKFEED <br />100A + 20A = 120A <br />BUSS RATING x 120% <br />100A x 120% = 120A <br />3 <br />L1 <br />L2 <br />N <br />G <br />= <br />AC DC <br />3 <br />100 A (EXISTING) <br />JUNCTION BOX <br />600 V, NEMA 3 <br />UL LISTED <br />- + <br />- + + <br />- + <br />+ + + - - - <br />2 <br />- + <br />- <br />1 3 <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />= <br />2 1 <br />10 11 <br />SolarEdge Power Optimizer P 401 Rated <br />DC Input Power - 401 watts <br />Maximum Input Voltage - 60 Vdc <br />MPPT Range - 8 to 60 Vdc <br />Maximum Input Current - 14.65 Adc <br />Maximum Output Current - 15 Adc String <br />Limitations - 8 to 25 Optimizers, <br />5700 watts STC per string maximum <br />PAGE 5 OF 15 <br />LONGI SOLAR LR4-60HPB <br />355M 355W MODULES <br />Conduit Type Conduit Size <br />EMT 3/4" <br />3/4" <br />3/4" <br />3/4" <br />EMT <br />EMT <br />EMT <br />INSIDE EMT-ON ROOF <br />INSIDE EMT-ON ROOF 3/4" <br />3/4" <br />GEC <br />BI-DIRECTIONAL UTILITY <br />METER 1-PHASE, 3-W, <br />120V/240V <br />UTILITY PROVIDER :- SCE <br />UTILITY METER # :- 222012-776153 <br />(E) MAIN BREAKER TO <br />HOUSE 240V, 100A/2P, <br />(TOP FED) <br />(E) MAIN SERVICE PANEL, <br />100A RATED, 240V <br />G <br />N <br />NL2L1 <br />M <br />TO UTILITY GRID <br />100A <br />20A/2P <br />(N) 20A/2P PV BREAKER AS <br />FAR AS POSSIBLE FROM <br />THE MAIN BREAKER <br />GROUNDING <br />ELECTRODE SYSTEM <br />L1 <br />L2 <br />L1 <br />L2 <br />N <br />G <br />N <br />G <br /> AC DISCONNECT <br />EATON#DG221URB 30A, <br />2P,600VAC NEMA 3R <br />SOLAREDGE TECHNOLOGY: <br />SE3800H-US <br />OUTPUT: 240 VAC, 16A <br />99% CEC WEIGHTED EFFICIENCY <br />NEMA 3R, UL LISTED, INTERNAL GFDI <br />WITH INTEGRATED DC DISCONNECT & <br />INTEGRATED RAPID SHUTDOWN <br />SERVICE INFO <br />UTILITY PROVIDER: SCE <br />UNDERGROUND <br />SYSTEM SIZE: <br />TOTAL DC SYSTEM SIZE: 3.91 kW DC <br />TOTAL AC SYSTEM SIZE: 3.8 kW AC <br />GENERAL ELECTRIC <br />2530 N Pacific Ave <br />09/22/22