Laserfiche WebLink
Power Optimizer <br />For North America <br />P370 / P400 / P401 / P485 / P505 <br />25 <br />YEAR <br />WARRANTY <br />PV power optimization at the module-level <br />Specifically designed to work with SolarEdge <br />inverters <br />Up to 25% more energy <br />Superior efficiency (99.5%) <br />Mitigates all types of module mismatch losses, <br />from manufacturing tolerance to partial <br />shading <br />Flexible system design for maximum space <br />utilization <br />Fast installation with a single bolt <br />Next generation maintenance with module- <br />level monitoring <br />Meets NEC requirements for arc fault <br />protection (AFCI) and Photovoltaic Rapid <br />Shutdown System (PVRSS) <br />Module-level voltage shutdown for installer <br />and firefighter safety <br />solaredge.com <br />PO <br />W <br />E <br />R <br /> <br />O <br />P <br />T <br />I <br />M <br />I <br />Z <br />E <br />R <br /> <br />Power Optimizer <br />For North America <br />P370 / P400 / P401 / P485 / P505 <br />Optimizer model <br />(typical module compatibility) <br />P370 <br />(for higher-power 60 <br />and 72-cell modules) <br />P400 <br />(for 72 & 96- <br />cell modules) <br />P401 <br />(for high power 60 <br />and 72 cell modules) <br />P485 <br />(for high-voltage <br />modules) <br />P505 <br />(for higher <br />current modules) <br />INPUT <br />Rated Input DC Power(1)370 400 430 485 505 W <br />Absolute Maximum Input Voltage <br />(Voc at lowest temperature)60 80 60 125(2)83(2)Vdc <br />MPPT Operating Range 8 - 60 8 - 80 8-60 12.5 - 105 12.5 - 83 Vdc <br />Maximum Short Circuit Current (Isc)11 10.1 12.5 11 14 Adc <br />Maximum DC Input Current 13.75 12.5 14.65 12.5 17.5 <br />Maximum Efficiency 99.5 % <br />Weighted Efficiency 98.8 % <br />Overvoltage Category II <br />OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) <br />Maximum Output Current 15 Adc <br />Maximum Output Voltage 60 80 Vdc <br />OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) <br />Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc <br />STANDARD COMPLIANCE <br />EMC FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3 <br />Safety IEC62109-1 (class II safety), UL1741, NEC/PVRSS <br />Material UL94 V-0 , UV Resistant <br />RoHS Yes <br />INSTALLATION SPECIFICATIONS <br />Maximum Allowed System Voltage 1000 Vdc <br />Compatible inverters All SolarEdge Single Phase and Three Phase inverters <br />Dimensions (W x L x H)129 x 153 x 27.5 / <br />5.1 x 6 x 1.1 <br />129 x 153 x 33.5 / <br />5.1 x 6 x 1.3 <br />129 x 153 x 29.5 / <br />5.1 x 6 x 1.16 <br />129 x 159 x 49.5 / <br />5.1 x 6.3 x 1.9 <br />129 x 162 x 59 / <br />5.1 x 6.4 x 2.3 <br />mm <br />/ in <br />Weight (including cables)630 / 1.4 750 / 1.7 655 / 1.5 845 / 1.9 1064 / 2.3 gr / lb <br />Input Connector MC4(3)MC4(3)MC4(3) <br />Input Wire Length 0.16 / 0.5 m / ft <br />Output Wire Type / Connector Double Insulated / MC4 <br />Output Wire Length 1.2 / 3.9 m / ft <br />Operating Temperature Range (4)-40 to +85 / -40 to +185 ˚C / ˚F <br />Protection Rating IP68 / Type6B <br />Relative Humidity 0 - 100 % <br />(1) Rated power of the module at STC will not exceed the optimizer “Rated Input DC Power”. Modules with up to +5% power tolerance are allowed <br />(2) NEC 2017 requires max input voltage be not more than 80V <br />(3) For other connector types please contact SolarEdge <br />(4) Longer inputs wire lengths are available for use. For 0.9m input wire length order P401-xxxLxxx <br />(5) For ambient temperature above +85°C / +185°F power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Technical Note for more details: https://www.solaredge.com/sites/default/files/se- <br />temperature-derating-note-na.pdf <br />PV System Design Using a SolarEdge <br />Inverter(6)(7) <br />Single Phase <br />HD-Wave Single phase Three Phase for <br />208V grid <br />Three Phase for <br />277/480V grid <br />Minimum String Length <br />(Power Optimizers) <br />P370, P400, P401 8 10 18 <br />P485, P505 6 8 14 <br />Maximum String Length (Power Optimizers)25 25 50 <br />Maximum Power per String <br />5700(8) (6000 with <br />SE7600-US - SE11400-US) 5250(8) 6000(9)12750(10)W <br />Parallel Strings of Different Lengths or Orientations Yes <br />(6) For detailed string sizing information refer to: http://www.solaredge.com/sites/default/files/string_sizing_na.pdf <br />(7) It is not allowed to mix P485/P505 with P370/P400/P401 in one string <br />(8) A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 30V requirement <br />(9) For 208V grid: it is allowed to install up to 6,500W per string when the maximum power difference between each string is 1,000W <br />(10)For 277/480V grid: it is allowed to install up to 15,000W per string when the maximum power difference between each string is 2,000W <br />© SolarEdge Technologies Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. <br />All other trademarks mentioned herein are trademarks of their respective owners. Date: February 10, 2022 DS-000044-NA. Subject to change without notice. <br />2606 S. Pacific <br />Ave.07/01/22