My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2606 S Pacific Ave - Plan
PBA
>
Building
>
ProjectDox
>
P
>
Pacific Ave
>
2606 S Pacific Ave
>
2606 S Pacific Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2025 4:53:29 PM
Creation date
5/30/2025 8:00:54 AM
Metadata
Fields
Template:
Plan
Permit Number
20176671
20178377
101111035
101113414
Full Address
2606 S Pacific Ave
Document Relationships
101111035 - Permit
(Permit - Plan)
Path:
\Building\Permits\P\Pacific Ave\2606 S Pacific Ave
101113414 - Permit
(Permit - Plan)
Path:
\Building\Permits\P\Pacific Ave\2606 S Pacific Ave
20176671 - Permit
(Permit - Plan)
Path:
\Building\Permits\P\Pacific Ave\2606 S Pacific Ave
20178377 - Permit
(Permit - Plan)
Path:
\Building\Permits\P\Pacific Ave\2606 S Pacific Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
PV-C PV-C <br />NON-FUSED <br />AC DISCONNECT <br />UTILITY <br />GROUNDING ROD(S) <br />SET @ 6' APART MIN. <br />4 <br />INVERTER #1 <br />PV-B <br />MAIN SERVICE PANEL <br />UTILITY METER <br />x UPGRADING (E) MAIN TO (N) <br />200A MAIN | 200A BUSBAR <br />(LOCATION PER UTILITY) <br />x (N) 40A PV OCPD C/B TO BE <br />INSTALLED OPPOSITE END <br />OF MAIN OCPD <br />M SOLAR: HC 144BB-440W MODULE <br />MOD. IMP: (10.74A) * (1 STRING) = 10.74A <br />MOD. ISC: (11.33A) * (1 STRING) = 11.33A <br />SYSTEM DC WIRING: STRING(S) OF ( 10) <br />VMP: (41.00 VDC MPP) * (10 MODS) = 410.0 VDC <br />VOC: (49.90 VOC) * (10 MODS) = 499.00 VDC <br />VMAX: (499.00 VDC) * (114%) = 568.86 VDC <br />STRING(DC): 4400W <br />ARRAY 1: (10) MODULES <br />ARRAY 2: (9) MODULES <br />(2) #10 PV-WIRE <br />UNDER EACH MODULE <br />FREE-AIR (SECURED) <br />(MANUFACTURE WIRE)1 <br />2 <br />PV-A 3 <br />J-BOX <br />x ALL CONDUCTOR(S) TO BE RAN IN RACEWAY <br />x PHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT <br />MAIN SERVICE FROM DC DISCONNECT/INVERTER AS PER [NEC 250.166(B)] <br />"THE GROUNDING ELECTRODE CONDUCTOR SHALL NOT BE SMALLER THEN <br />THE LARGEST CONDUCTOR SUPPLIED BY THE SYSTEM & NOT SMALLER THEN <br />#8 AWG." <br />x SYSTEM GROUNDING ELECTRODE CONDUCTOR FOR PHOTOVOLTAIC SYSTEM <br />SIZED TO MEET THE REQUIREMENTS OF 250.66 (AC) & 250.66 (DC), 690.74(C) <br />NOT SMALLER THEN #8 AWG <br />x EQUIPMENT OPERATING 150V OR GREATER SHALL ONLY BE SERVICED OR <br />REPLACED BY QUALIFIED PERSONNEL. FIELD PROTECTION MAY BE IN THE <br />FORM OF CONDUIT, CLOSED CABINET OR AN ENCLOSURE WHICH REQUIRES <br />USE OF TOOLS TO OPEN. <br />x SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN <br />ACCORDANCE W/ REQUIREMENTS OF ARTICLE 690 OF THE 2019 CEC. <br />x MIN. HEIGHT OF CONDUIT ABOVE ROOF TO MATCH TEMP. DE-RATING <br />FACTOR <br />x PHOTOVOLTAIC DC CONDUCTORS ENTERING THE BUILDING SHALL BE <br />INSTALLED IN METAL CONDUIT & THE CONDUIT SHALL BE LABELED "CAUTION <br />DC CONDUIT" EVERY 10-FEET <br />x SMOKE ALARMS & CARBON MONOXIDE DETECTORS WILL MEET THE <br />NECESSARY REQUIREMENTS PER [CRC R314, R315] <br />x UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE <br />PHOTOVOLTAIC SOLAR SYSTEM <br />x GROUNDING TO BE INSTALLED PER MODULE MANUFACTURE INSTRUCTIONS. <br />GROUND METHOD: GROUND LUGS WITH BARE COPPER WIRE <br />ELECTRICAL EQUIPMENT LIST <br />#ITEM DESCRIPTION QTY. <br />1INVERTER #1 SOLAREDGE: SE6000H-US4 <br />19MODULE M SOLAR: HC 144BB-440W 1 <br />19POWER <br />OPTIMIZER SOLAREDGE: P4852 <br />1JUNCTION BOX UL-LISTED WATER-TIGHT <br />NEMA 3R RATED3 <br />5 <br />6 <br />1PV BREAKER <br />(OCPD)40A-2P, 240V 7 <br />6 MAIN SERVICE <br />PANEL 1 <br />UPGRADING (E) MAIN <br />SERVICE PANEL TO <br />(N) 200A MAIN | 200A BUSBAR <br />5 160A, 2P-240V, BLADE TYPEAC DISCONNECT <br />(NON-FUSED) <br />SYSTEM DC WIRING: STRING(S) OF ( 9) <br />VMP: (41.00 VDC MPP) * (9 MODS) = 369.0 VDC <br />VOC: (49.90 VOC) * (9 MODS) = 449.1 VDC <br />VMAX: (449.1 VDC) * (114%) = 511.97 VDC <br />STRING(DC): 3960W <br />SOLAREDGE: SE6000H-US INVERTER <br />MAX AC OUTPUT: 6000WAC <br />MAX DC INPUT: 9300WDC <br />NOM VOLTAGE: 240VAC <br />MAX INPUT VOLTAGE: 480VDC <br />NOM DC INPUT VOLTAGE: 380VDC <br />MAX CONT. OUTPUT CURRENT: 25A <br />MAX INPUT SHORT CIRCUIT: 45A <br />SOLAREDGE: P485 OPTIMIZER <br />MAX VOLTAGE: 80VDC|INPUT DC: 485W <br />MAX ISC: 11ADC|MAX DC INPUT: 12.5ADC <br />STRING MIN.: 6|MAX PER STRING: 5700W <br /> (SE7600-SE11400: 6000W) <br />UTILITY <br />PREPARED BY:DATE: <br />PROJECT #: <br />SHEET NAME: <br />SHEET #: <br />PROPOSED EQUIPMENT: SCOPE OF WORK:HOMEOWNER:CONTRACTOR: <br />PV-E.01 <br />ELECTRICAL <br />17.67 <br />TABLE 310.15(B)(16) <br />Zd/E'ΛϵϬΣ <br />(4) #10 THWN-2 <br />32.13 <br />TABLE 310.15(B)(16) <br />Zd/E'ΛϵϬΣ <br />(4) #10 THWN-2 <br />TABLE 310.15(B)(3)(a) <br /># OF COND. (3) MAX. <br />SYSTEM AC WIRING TOTAL: ENTIRE SYSTEM <br />SYSTEM WAC: 7712.1WAC <br />MODULE ISC: 11.33A * 156% = 17.67A >PV-B DESIGN <br />SYSTEM IMP: 32.13A >PV-C DESIGN <br />SYSTEM PMAX: 40.00A ----> 40A C/B >SYSTEM OCPD <br />SYSTEM AC WIRING RUN: INVERTER #1 <br />CONTINUOUS OUTPUT CURRENT (IMP): <br />(410.0 PTC RATING) * (19 MOD.) * (99.0% CEC INV. EFF.) = <br />7712.1WAC / 240VAC = 32.13A <br />MAX OUTPUT CURRENT (PMAX): <br />32.0A* 125% = 40.00A ---> 40A OCPD C/B <br />TABLE 310.15(B)(3)(a) <br /># OF COND. (3) MAX. <br />7 <br /> (25ΣͲ;22.2Σн22ΣͿΎ;Ͳ0.36йͬΣͿс6.92% VOLTAGE DROP <br /> (41.0VMP) * (6.92%) = 2.84V PER - (41.0VMP) = 38.2V VMP <br /> (38.2V) * (ARRAY OF 10) = 381.63V @ AVR. HIGH 22.2 Σ <br />(200A BUSBAR) * (120%) = 240A MAX. <br />200A MAIN BREAKER + 40A PV BACKFEED = 240A <br />240ч240A PER [CEC 705.12 (B)(2)(3)(b)] <br />LARSUN SOLAR <br />CSLB: #583458 (C-46) <br />ADDRESS: 439 E HARRISON ST. UNIT E <br />CITY|ZIP: CORONA | CA | 92879 <br />PHONE: (951) 298-9007 <br />best solar <br />3/10/2022 <br />HP-089 <br />INSTALL A NEW 8.36kW (DC)|7.71kW(AC)|7.72kW (CEC AC) PV SOLAR SYSTEM ON AN <br />(E) RESIDENTIAL ROOF. ALL WORK TO BE CONDUCTED UNDER AN ACTIVE CSLB LICENSE <br />& SHALL ADHERE TO ALL FEDERAL|STATE|LOCAL LAWS & CODES. PLEASE REFERENCE <br />ALL CODE(S) THROUGHOUT THIS PLAN SET FOR FULL COMPLIANCE. <br />THE BOUACHINE SOUVANNAVONG RESIDENCE <br />2606 S PACIFIC AVE. <br />SANTA ANA | CA | 92704 <br />APN #: 14027102 <br />ALL-AMERICAN <br />SOLAR SERVICES <br />L.L.C. <br />x AJC <br /> (19) M SOLAR: HC 144BB-440W MOD. <br /> (19) SOLAREDGE: P485 OPTMZR. <br /> (1) SOLAREDGE: SE6000H-US INV. <br />2606 S. Pacific <br />Ave.07/01/22
The URL can be used to link to this page
Your browser does not support the video tag.