(N) JUNCTION <br />BOX <br />6" X 6" X 4" UL LISTED, <br />WATER-TIGHT NEMA TYPE 3,13 <br />MAIN SERVICE <br />PANEL 14 <br />(N) MAIN SERVICE PANEL & METER: <br />200A MAIN BUSBAR W/ (N) 200A END <br />FED MAIN BREAKER 705.12(B)(2)(3)(b) <br />5 (N) PV BREAKER (N) 20A-2P, 240V AC 1 <br />(N) AC <br />DISCONNECT 1 <br />SQUARE-D DU221RB, GENERAL USE <br />SWITCH, 30A 2 POLE, LOCKABLE IN <br />THE OFF POSITION, W/VISIBLE <br />BLADES. 240V NON FUSIBLE NEMA <br />3R <br />7 <br />ELECTRICAL EQUIPMENT LIST <br />ITEM DESCRIPTION QTY <br />(N) INVERTER 12 <br />SOLAREDGE SE3000H US <br />CEC AC EFFICIENCY @ 240VAC = 99% <br />WAC CONTINUOUS = 3000W AC <br />MAX OUTPUT CURRENT = 12.5A AC <br />MAX INPUT CURRENT = 8.5A DC <br />EQUIPPED WITH RAPID SHUTDOWN, REVENUE <br />GRADE METER, AND INTERGRATED DC <br />DISCONNECT SWITCH <br />NEMA4X <br />(N) POWER <br />OPTIMIZER 10 6 <br />SOLAREDGE P401 OPTIMIZER <br />RATED DC INPUT POWER = 400W DC <br />MAX. INPUT VOLTAGE = 60V DC <br />MAX. DC OUTPUT VOLTAGE = 60V DC <br />MPPT RANGE = 8 TO 60V DC <br />MAX. INPUT CURRENT = 11.75A DC <br />MAX. OUTPUT CURRENT = 15A DC <br />PV MODULE 101 <br />CANADIAN SOLAR CS3N-390MS <br />IP67/NEMA 6P <br />OPEN CIRCUIT VOLTAGE (VOC) = 44.1V <br />MAX. POWER VOLTAGE (VMP) = 36.8V <br />SHORT CIRCUIT CURRENT (ISC) = 11.62A <br />MAX. POWER CURRENT (IMP) = 10.6A <br />PER CEC END FED MAIN BREAKER <br />705.12(B)(2)(3)(b) <br />MSP BUS BAR = 200A <br />200Ax1.2=240A <br />LARGEST OCPD : 240A-200A=40A <br />KEY NOTES: <br />- SOLID BARE E.G.C. (FREE-AIR) MOUNTED UNDER ARRAY <br />- PER CEC 250.120(C): WHERE CONDUCTORS & GROUND WIRE ARE RUN EXPOSED <br />ON FROM ARRAY TO J-BOX, CONDUCTORS & BARE GROUND WIRE SHALL BE <br />CONCEALED INSTALL IN CONDUIT <br />- PER CEC ARTICLE 690.35 INVERTER GROUND FAULT PROTECTION PROVIDED <br />- ALL GROUNDS AND NEUTRALS BONDED TO EXISTING GROUNDING CONDUCTOR <br />W/ IRREVERSIBLE CRIMP CONNECTOR. <br />- BACKFED BREAKERS MUST BE LOCATED @ OPPOSITE END OF BUS BAR FROM MAIN <br />BREAKER OR MAIN LUG ON GRID SIDE. WHEN A BACKFED BREAKER IS THE METHOD <br />OF UTILITY INTERCONNECTION, BREAKER SHALL NOT READ 'LINE OR LOAD'. <br />- PER CEC 250.64(C): CONDUCTOR SPLICES ONLY ALLOWED WITH COMPRESSION <br />CONNECTORS OR EXOTHERMIC WELDING <br />- ALL GROUNDS AND NEUTRALS BONDED TO EXISTING GROUNDING CONDUCTOR W/ <br />IRREVERSIBLE CRIMP CONNECTOR. <br />- VERIFY (E) UFER GROUND NEAR MSP. IF (E) UFER IS NOT ACCESSIBLE OR VERIFIABLE, <br />INSTALL A NEW 5/8"Ø X 8' LONG EMBEDDED GROUNDING ROD AND BOND SOLAR <br />SYSTEM EQUIPMENT GROUNDING ACCORDINGLY. <br />120/240V <br />1-PH, 3W <br />INCOMING <br />UTILITY <br />SERVICE <br />MAIN <br />BREAKER <br />120/240V <br />1-PH, 3W <br />INCOMING <br />UTILITY <br />SERVICE <br />M <br />4 <br />5 <br />200 <br />METER # <br />222013-500865 <br />4 <br />7 <br />4 <br />(STRING 1) <br />1 STRING OF 10 <br />PV MODULES <br />2 <br />3 <br />JUNCTION <br />BOX <br />3 <br />1 <br />6 <br />1 <br />2 <br />INVERTER #1 <br />W/ INTEGRATED <br />GFCI & AFCI <br />PROTECTION <br />4 <br />2 <br />MC <br />P <br />H <br />E <br />R <br />S <br />O <br />N <br /> <br />E <br />N <br />G <br />I <br />N <br />E <br />E <br />R <br />I <br />N <br />G <br />Ju <br />r <br />u <br />p <br />a <br /> <br />V <br />a <br />l <br />l <br />e <br />y <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />5 <br />0 <br />9 <br />(9 <br />0 <br />9 <br />) <br /> <br />5 <br />6 <br />6 <br />- <br />0 <br />0 <br />6 <br />6 <br />ry <br />a <br />n <br />@ <br />m <br />c <br />p <br />e <br />. <br />g <br />r <br />o <br />u <br />p <br />De <br />s <br />i <br />g <br />n <br />e <br />d <br /> <br />b <br />y <br />92 <br />4 <br />0 <br /> <br />L <br />i <br />m <br />o <br />n <br />i <br />t <br />e <br /> <br />A <br />v <br />e <br />1 <br />6 <br />1 <br />1 <br /> <br />P <br />O <br />M <br />O <br />N <br />A <br /> <br />R <br />D <br />. <br /> <br />S <br />T <br />E <br /># <br /> <br />2 <br />0 <br />6 <br />CO <br />R <br />O <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />8 <br />7 <br />8 <br />(9 <br />5 <br />1 <br />) <br /> <br />2 <br />9 <br />8 <br />- <br />9 <br />0 <br />0 <br />7 <br />CS <br />L <br />B <br /># <br /> <br />1 <br />0 <br />4 <br />3 <br />1 <br />0 <br />8 <br />DA <br />T <br />E <br />: <br /> <br />6/ <br />2 <br />2 <br />/ <br />2 <br />0 <br />2 <br />2 <br /> <br /> <br /> <br /> <br /> <br />PL <br />O <br />T <br />T <br />E <br />D <br />: <br /> <br />8/ <br />1 <br />0 <br />/ <br />2 <br />0 <br />2 <br />2 <br />DE <br />S <br />I <br />G <br />N <br />E <br />R <br />: <br /> <br /> K <br />. <br />I <br />. <br /> <br /> A <br />H <br />J <br />: <br /> <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />3. <br />9 <br />0 <br />0 <br /> k <br />W <br />p <br />D <br />C <br /> <br />/ <br /> <br />3. <br />6 <br />0 <br />7 <br /> k <br />W <br />p <br />A <br />C <br />PH <br />O <br />T <br />O <br />V <br />O <br />L <br />T <br />A <br />I <br />C <br /> <br />S <br />Y <br />S <br />T <br />E <br />M <br /> <br />P <br />L <br />A <br />N <br />ER <br />I <br />N <br /> <br />K <br />E <br />L <br />L <br />Y <br />26 <br />2 <br />1 <br /> <br />R <br />A <br />M <br />O <br />N <br />A <br /> <br />D <br />R <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />71 <br />4 <br />- <br />7 <br />2 <br />4 <br />- <br />2 <br />9 <br />7 <br />2 <br />AP <br />N <br />: <br /> <br />1 <br />4 <br />0 <br />1 <br />6 <br />2 <br />1 <br />9 <br />SINGLE <br />LINE <br />DIAGRAM <br />PV4 <br />OVERHEAD FED MSP <br />2621 S Ramona Dr <br />08/29/22