My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2634 N Oakmont Ave - Plan
PBA
>
Building
>
ProjectDox
>
O
>
Oakmont Ave
>
2634 N Oakmont Ave
>
2634 N Oakmont Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2025 1:41:56 PM
Creation date
5/30/2025 8:00:54 AM
Metadata
Fields
Template:
Plan
Permit Number
20176238
101110511
Full Address
2634 N Oakmont Ave
Document Relationships
101110511 - Permit
(Permit - Plan)
Path:
\Building\Permits\O\Oakmont Ave\2634 N Oakmont Ave
20176238 - Permit
(Permit - Plan)
Path:
\Building\Permits\O\Oakmont Ave\2634 N Oakmont Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Solar Photovoltaic System <br />BENJAMIN FERENC <br />2634 OAKMONT AVE <br />SANTA ANA, CA 92705 <br />(626)367-3951 <br />NEW GEN ENERGY <br />CORPORATION <br />P.O. Box 143, Placentia, <br />CA 92871-0143 <br />Phone: (909) 215-5291 <br />CSLB Lic# 949365 (C-10) <br />X:_____________________ <br />_ <br />ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH ARTICLE 250. ALL <br />CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALL HAVE OVERCURRENT DEVICES LOCATED SO <br />AS TO PROVIDE OVERCURRENT PROTECTION FROM ALL SOURCES 690.9 (A) <br />PV ARRAYS ARE PER SINGLE LINE. <br />PV ARRAY WIRING TO JUNCTION IS #10 AWG PV WIRE W/ FIELD INSTALLED MC CONNECTORS TO INTERFACE W/ MODULES. <br />PV POWER SOURCE DISCONNECT (INTEGRATED) RATED AT 36 AMPS, 600Vdc, NEMA 3R RAINPROOF. <br />USE UFER GROUND ELECTRODE SYSTEM FROM INVERTER TO EXISTING MAIN SERVICE GROUND ELECTRODE PER N.E.C. <br />250.58. <br />WHEN REQUIRED, GROUND ELECTRODE CONDUCTOR FROM INVERTER TO GROUND ELECTRODE TO BE MINIMUM PROTECTION <br />OF BARE ARMOR SHEATHED CABLE FOR ALL CONDUCTOR SIZES. <br />ALL GROUND CONNECTED TO MAIN SERVICE GROUND IN MAIN SERVICE PANEL. <br />INVERTER SHALL BE PER ATTACHED CUT SHEET. <br />AC DISCONNECT SHALL BE PER SINGLE LINE. <br />EQUIPMENT GROUNDING CONDUCTORS ON AC AND DC SIDE SIZED ACCORDING TO NEC 690. <br />POLE OF PV ARRAY REFERENCED TO GROUND AT THE INVERTER IN SINGLE LINE. <br />ALL CONDUCTORS SHALL BE 600V, 90C STANDARD COPPER. ALL CONDUCTORS IN CONDUIT SHALL BE THWN-2. <br />MAXIMUM DC VOLTAGE DROP SHALL BE 1.5% <br />ALL CONDUCTORS SHALL BE IN CONDUIT UNLESS OTHERWISE NOTED. <br />ALL WORK TO COMPLY WITH 2019 CALIFORNIA ELECTRIC CODE, 2019 CALIFORNIA BUILDING CODE <br />EXACT CONDUIT RUN LOCATIONS SUBJECT TO CHANGE. <br />3.0 PSF MAX (.5 PSF FROM RACKING, 2.5 PSF FROM MODULES) DEAD LOAD CONTRIBUTED FROM SOLAR ARRAY. <br />CONDUCTORS ON ROOF ARE TO BE 0.875" OFF OF THE ROOF SURFACE. <br />GEC TO BE CONNECTED TO EXISTING UFER. F UFER IS NOT PRESENT THEN A NEW GROUND ROD WILL BE ADDED FOR <br />GROUNDNG PURPOSES. <br />PV WIRES UTILIZED IN SYSTEM ARE UL-4703 COMPLIANT. <br />ON RESIDENTIAL ROOF INSTALLATIONS ALL RACKING AND MODULES ARE UL2703 COMPLIANT <br />PV-3A <br />DATE: <br />ELECTRICAL NOTES, <br />LOAD CALCS <br />ELECTRICAL NOTES <br />4/27/2022 <br />GROUNDING: <br />IRONRIDGE INTEGRATED <br />CLAMP <br />MODEL: UFO <br />UL LISTED #2703 <br />"PV SYSTEM TO BE IRREVERSIBLY CONNECTED TO UFER, IF UFER IS NOT PRESENT IT IS THE RESPONSIBILITY OF THE <br />CONTRACTOR TO BRING GROUNDING UP TO CODE." <br />2634 N Oakmont <br />Ave05/24/22
The URL can be used to link to this page
Your browser does not support the video tag.