My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2713 S Diamond St - Plan
PBA
>
Building
>
ProjectDox
>
D
>
Diamond St
>
2713 S Diamond St
>
2713 S Diamond St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2025 1:42:27 PM
Creation date
5/30/2025 8:00:54 AM
Metadata
Fields
Template:
Plan
Permit Number
20176740
101111134
Full Address
2713 S Diamond St
Document Relationships
101111134 - Permit
(Permit - Plan)
Path:
\Building\Permits\D\Diamond St\2713 S Diamond St
20176740 - Permit
(Permit - Plan)
Path:
\Building\Permits\D\Diamond St\2713 S Diamond St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
REV <br />SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />ANSI B <br />11" X 17" <br />DATE DESCRIPTION <br />REVISIONS <br />Signature with Seal <br />PROJECT NAME & ADDRESS <br />PV-6 <br />PROJECT ID <br />BE <br />T <br />T <br />Y <br /> <br />P <br />U <br />G <br />H <br />27 <br />1 <br />3 <br /> <br />S <br /> <br />D <br />I <br />A <br />M <br />O <br />N <br />D <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />, <br />U <br />S <br />A <br />WIRING <br />CALCULATIONS <br />ELECTRICAL NOTES <br />1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. <br />2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. <br />3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS <br />POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. <br />4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. <br />5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, <br />SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. <br />6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM <br />ACCORDINGLY. <br />7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. <br />8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE <br />GROUNDING CLIP MANUFACTURER'S INSTRUCTION. <br />9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. <br />10.) THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE <br />AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT <br />PER NEC 310.15(B)(2)(c): + 22° <br />EXPECTED WIRE TEMP (°C): 31 ° + 22° <br />TEMP CORRECTION PER TABLE 310.15: 0.76 <br />#OF CURRENT CARRYING CONDUCTORS: 6 <br />CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a): 0.80 <br />CIRCUIT CONDUCTOR SIZE: 10 AWG <br />CIRCUIT CONDUCTOR AMPACITY: 40A <br />REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B): <br />1.25 X MAX AC OUTPUT CURRENT X # OF INVERTERS PER STRING <br />STRING #1 : 1.25 X 1.21 X 10 = 15.13A <br />STRING #2 & #3 : 1.25 X 1.21 X 9 = 13.61A <br />DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.15 <br />TEMP CORR. PER NEC TABLE 310.15 X <br />CONDUIT FILL CORR. PER NEC 310.15(B)(2)(a) X <br />CIRCUIT CONDUCTOR AMPACITY = 0.76 X 0.80 X 40 = 24.32A <br />EXPECTED WIRE TEMP (°C): 31 ° <br />TEMP CORRECTION PER NEC TABLE 310.15: 0.96 <br />CIRCUIT CONDUCTOR SIZE: 8 AWG <br />CIRCUIT CONDUCTOR AMPACITY: 55A <br />#OF CURRENT CARRYING CONDUCTORS: 3 <br />CONDUIT FILL PER NEC 310.15(B)(2)(a): 1.00 <br />REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B): <br />1.25 X OUTPUT CURRENT OF LOAD CENTER <br />1.25 X 1.21 X 28 = 42.35A <br />DERATED AMPACITY OF CIRCUIT CONDUCTORS PER NEC TABLE 310.15: <br />TEMP CORR. PER NEC 310.15 X <br />CONDUIT FILL CORR. PER NEC 310.15(B)(2)(a) X <br />CIRCUIT CONDUCTOR AMPACITY = <br />0.96 X 1.00 X 55 = 52.8A <br />AMBIENT TEMPERATURE SPECS <br />AMBIENT TEMP (HIGH TEMP 2%) <br />RECORD LOW TEMP 2° <br />31° <br />CONDUIT HEIGHT 0.5" <br />ROOF TOP TEMP 53° <br />CONDUCTOR TEMPERATURE RATE 90° <br />0.5" <br />INVERTER SPECIFICATIONS <br />MANUFACTURER / MODEL #ENPHASE IQ7PLUS-72-2-US <br />NOMINAL OUTPUT CURRENT 1.21A <br />NOMINAL OUTPUT VOLTAGE 240 VAC <br />NUMBER OF CURRENT <br />CARRYING CONDUCTORS IN <br />EMT <br />4-6 <br />7-9 <br />10-20 <br />PERCENT OF <br />VALUES <br />.80 <br />.70 <br />.50 <br />SOLAR MODULE SPECIFICATIONS <br />MANUFACTURER / MODEL #CANADIAN SOLAR CS3U 385MS 385 <br />(385W)MODULES <br />VMP 40.2 <br />IMP 9.58 <br />VOC 48.0 <br />ISC 10.09 <br />MODULE DIMENSION 78.7"L x 39.1"W x 1.38"D (In Inch) <br />AC CONDUCTOR AMPACITY CALCULATIONS: <br />FROM ROOF TOP JUNCTION BOX TO IQ COMBINER BOX <br />AC CONDUCTOR AMPACITY CALCULATIONS: <br />FROM IQ COMBINER BOX TO MSP <br />EVERGREEN SOLAR & <br />CONSTRUCTION INC. <br />ROSHAWN HELMANDI <br />8728 ZELZAH AVE <br />NORTHRIDGE, CA 91325 <br />(818) 324-9956 <br />LIC # B&C 10-1067368 <br />EXP: 07-31-2022 <br />2713 S Diamond St <br />- 2017674008/11/22
The URL can be used to link to this page
Your browser does not support the video tag.