My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2880 N Main St - Plan
PBA
>
Building
>
ProjectDox
>
M
>
Main St
>
2880 N Main St
>
2880 N Main St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/13/2025 5:15:14 AM
Creation date
5/30/2025 8:00:55 AM
Metadata
Fields
Template:
Plan
Permit Number
20171818
101104398
Full Address
2880 N Main St
Street Number
2880
Street Direction
N
Street Name
Main
Street Suffix
St
Document Relationships
101104398 - Permit
(Permit - Plan)
Path:
\Building\Permits\M\Main St\2880 N Main St
20171818 - Permit
(Permit - Plan)
Path:
\Building\Permits\M\Main St\2880 N Main St
Text box
ID:
1
Creator:
Import Agent
Created:
5/30/2025 4:42 PM
Modified:
5/30/2025 9:07 AM
Text:
http://www.energy.ca.gov/title24/2019standards
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance: http://www.energy.ca.gov/title24/2019standards April 2019 <br />STATE OF CALIFORNIA <br />Outdoor Lighting <br />NRCC-LTO-E (Created 4/19) CALIFORNIA ENERGY COMMISSI19 <br />Page 6 of 8 <br />CERTIFICATE OF COMPLIANCE NRCC-LTO-E <br />Project Name: Bank of America 2016 Exterior Lighting Program CAW-432 Report Page: <br />Project Address: 2880 N. Main St. Date Prepared: 07/13/2020 <br />01 <br />Area Description <br />02 <br />Illuminated Area <br />(ft2) <br />Allowed Density <br />(W/ft2) <br />Extra Allowance <br />(Watts) <br />CALCULATED ALLOWANCE (Watts) <br />03 04 05 <br />Luminaire <br />Name or <br />Item Tag <br />Watts per <br />Luminaire1,2 <br /># of <br />Luminaires² <br />DESIGN WATTS <br />06 07 <br />Design Watts <br />08 09 <br />Additional <br />Allowance <br />(Watts) <br />Parking Lot 26,953 0.013 350.389 UU1 229 2 458 <br />Total Design Watts for this Area: 458 350.389 <br />Total Allowance (Watts) Ornamental: 350.389 <br />¹ FOOTNOTES: Luminaires qualifying for this allowance shall be rated < 100W and shall be post-top luminaires, lanterns, pendants or chandeliers. <br />² For luminaires indicated in Table F as linear, wattage in column 06 is W/lf instead of Watts/luminaire. Total linear feet for the luminaire should be indicated in column 07 <br />instead of number of luminaires. <br />M. LIGHTING ALLOWANCE: PER SPECIFIC AREA <br />Table Instructions: Please complete this table for areas using the wattage allowance per specific area type from Table 140.7-B. More than one specific area allowance may be <br />taken in a single project, if applicable. However, multiple specific area allowances may not be taken for the exact same area on the site. <br />01 <br />Area Description <br />02 <br />Specific Area Type per <br />Table 140.7-B <br />03 <br />Specific <br />Area <br />(ft2)¹ <br />Allowed <br />Density <br />(W/ft2) <br />Extra <br />Allowance <br />(Watts) <br />CALCULATED ALLOWANCE (Watts) <br />04 05 06 <br />Luminaire <br />Name or <br />Item Tag <br />Watts per <br />Luminaire² <br /># of <br />Luminaires² <br />DESIGN WATTS <br />07 08 09 <br />Design Watts <br />10 <br />Additional <br />Allowance <br />(Watts) <br />Security Parking Lot Security for Retail Parking <br />& Pedestrian Hardscape 26,953 0.01 269.53 UU2 115 2 230 <br />0 UU3 77 1 77 <br />Total Design Watts for this Area: 307 269.53 <br />Total Allowance (Watts) All Areas: 269.53 <br />Table Continued <br />2020-160821 <br />12/07/20
The URL can be used to link to this page
Your browser does not support the video tag.