Laserfiche WebLink
MS <br />P <br />UM <br />AC <br />D <br /> I <br />N <br />V <br />JB <br />4'-10" 5'-9" 1'-11" <br />1' <br />- <br />8 <br />" <br />17 <br />' <br />- <br />4 <br />" <br />11 <br />' <br />- <br />1 <br />0 <br />" <br />3"11'-7" 5'-9"16'-4" <br />9' <br />- <br />1 <br />" <br />10 <br />' <br />- <br />5 <br />" <br />11 <br />' <br />- <br />7 <br />" <br />REV <br />SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />ANSI B <br />11" X 17" <br />DATE DESCRIPTION <br />REVISIONS <br />Signature with Seal <br />PROJECT NAME & ADDRESS <br />PV-2 <br />PROJECT ID <br />MA <br />R <br />T <br />H <br />A <br /> <br />R <br />A <br />M <br />I <br />R <br />E <br />Z <br />29 <br />0 <br />5 <br /> <br />W <br /> <br />W <br />I <br />L <br />L <br />I <br />T <br />S <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />, <br />U <br />S <br />A <br />FRESH03/03/2022 ORIGINAL PLAN <br />2065 W OBISPO AVE #102 <br />GILBERT, AZ 85233 USA <br />866-572-2637 <br />LIC # CA-1019100 <br />ABHISHEK MAHESH <br />ROOF PLAN & <br />MODULES <br />ROOF DESCRIPTION <br />ROOF TYPE COMP SHINGLE <br />ROOF ROOF TILT AZIMUTH RAFTERS <br />SIZE <br />RAFTERS <br />SPACING <br />#1 20°180° 2"x4"24" o.c. <br />#2 20°270° 2"x4"24" o.c. <br />#3 20°270° 2"x4"24" o.c. <br />#4 20°90° 2"x4"24" o.c. <br />LEGEND <br />- JUNCTION BOX <br />MSP - MAIN SERVICE PANEL <br />- VENTS, DISH (ROOF OBSTRUCTION) <br />- ROOF ATTACHMENT <br />- RAFTERS <br />- CONDUIT <br />- UTILITY METER <br />SCALE: 3/32" = 1'-0" <br />- SOLAREDGE OPTIMIZER <br />MODULE TYPE, DIMENSIONS & WEIGHT <br />ACD - AC DISCONNECT <br />- INVERTER <br />1 <br />PV-2 <br />NUMBER OF MODULES = 20 MODULES <br />MODULE TYPE = LONGI SOLAR LR4-60HPB 355M 355W MODULES <br />MODULE WEIGHT = 42.99 LBS / 19.5 KG. <br />COMPONENT WEIGHT: 1.5 LBS. PER MODULE <br />TOTAL DEAD LOAD: 889.80 LBS. <br />POINT LOAD PER STANDOFF.: 889.80 LBS / 49 STANDOFF = 18.16 LBS <br />MODULE DIMENSIONS = 69.09"x 40.87" = 19.61 SF <br />UNIT WEIGHT OF ARRAY = 2.27 PSF <br />UM <br />JB <br />INV <br />ARRAY AREA WITH TOTAL ROOF AREA <br />ROOF # OF <br />MODULES <br />ARRAY AREA <br />(Sq. Ft.) <br />TOTAL <br />ROOF <br />AREA <br />(Sq. Ft.) <br />ROOF <br />AREA <br />COVERED <br />BY ARRAY <br />(%) <br />#1 7 137.26 481.16 28.53 <br />#2 3 58.83 210.80 27.91 <br />#3 5 98.05 324.05 30.26 <br />#4 5 98.05 517.04 18.96 <br />ROOF PLAN & MODULES <br />PAGE 2 OF 17 <br />ARRAY AREA WITH WHOLE ROOF AREA <br />ROOF # OF <br />MODULES <br />ARRAY AREA <br />(Sq. Ft.) <br />TOTAL <br />ROOF <br />AREA <br />(Sq. Ft.) <br />ROOF <br />AREA <br />COVERED <br />BY ARRAY <br />(%) <br />#1-4 20 392.18 2874.43 13.64 <br />LONGI SOLAR <br />LR4-60HPB 355M <br /> 355W MODULES <br />40.87" <br />69 <br />. <br />0 <br />9 <br />" <br />- GAS METERGAS <br />(N) CHIKOUSA 7 RAILS <br />RACKING SYSTEM <br />(20) SOLAREDGE POWER <br />OPTIMIZER P-401 <br />(49) CHIKOUSA L FOOT <br />ATTACHMENTS @48"O.C. <br />(E) FRONT OF RESIDENCE <br />W WILLITS ST <br />(E) BACK OF RESIDENCE <br />ROOF #04 <br />(05) LONGI SOLAR LR4-60HPB <br />355M 355W MODULES <br />ROOF #01 <br />(07) LONGI SOLAR LR4-60HPB <br />355M 355W MODULES <br />ROOF ACCESS POINT <br />(N) MAIN SERVICE PANEL, <br />200A RATED, 240V, <br />(FLUSH MOUNTED) <br />(N) SOLAREDGE TECHNOLOGY : <br />SE5000H-US INVERTER <br />INTEGRATED RAPID SHUTDOWN <br />(N) AC DISCONNECT <br />(E) UTILITY METER <br />ROOF #02 <br />(03) LONGI SOLAR LR4-60HPB <br />355M 355W MODULES <br />ROOF #03 <br />(05) LONGI SOLAR LR4-60HPB <br />355M 355W MODULES <br />ROOF #1 <br />TILT - 20° <br />AZIM. - 180° <br />RO <br />O <br />F <br /> <br /># <br />2 <br />TI <br />L <br />T <br /> <br />- <br /> <br />2 <br />0 <br />° <br />AZ <br />I <br />M <br />. <br /> <br />- <br /> <br />2 <br />7 <br />0 <br />° <br />RO <br />O <br />F <br /> <br /># <br />4 <br />TI <br />L <br />T <br /> <br />- <br /> <br />2 <br />0 <br />° <br />AZ <br />I <br />M <br />. <br /> <br />- <br /> <br />9 <br />0 <br />° <br />RO <br />O <br />F <br /> <br /># <br />3 <br />TI <br />L <br />T <br /> <br />- <br /> <br />2 <br />0 <br />° <br />AZ <br />IM <br />. <br /> <br />- <br /> <br />2 <br />7 <br />0 <br />° <br />18" FIRE SETBACK <br />18" FIRE SETBACK <br />18" FIRE SE <br />T <br />B <br />A <br />C <br />K <br />18" FIR <br />E <br /> <br />SETBAC <br />K <br />18" FIR <br />E SE <br />T <br />B <br />ACK <br />18" FIRE SETB <br />A <br />C <br />K <br />18 <br />" <br /> <br />F <br />I <br />R <br />E <br /> <br />S <br />E <br />T <br />B <br />A <br />C <br />K <br />18 <br />" <br /> <br />F <br />I <br />R <br />E <br /> <br />S <br />E <br />T <br />B <br />A <br />C <br />K <br />36 <br />" <br /> <br />F <br />I <br />R <br />E <br /> <br />S <br />E <br />T <br />B <br />A <br />C <br />K <br />36" <br /> <br />F <br />I <br />R <br />E <br /> <br />S <br />E <br />T <br />B <br />A <br />C <br />K <br />18" FIRE SETBACK <br />18" FIRE SETBACK <br />3/4" EMT CONDUIT <br />RUN ON ROOF <br />(N) JUNCTION BOX <br />(E) PATIO <br />VECTOR PROJECT #: A0035-0162-221 <br />Vector Structural Engineering has reviewed the <br />existing structure with loading from the solar array. <br />The design of the racking system, connections, and <br />all other structure is by others. Electrical, mechanical, <br />architectural, and all other nonstructural aspects of <br />the design are by others. <br />Mar 16, 2022 <br />2905 W Willits <br />05/24/22