Laserfiche WebLink
REV <br />SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />ANSI B <br />11" X 17" <br />DATEDESCRIPTION <br />REVISIONS <br />Signature with Seal <br />PROJECT NAME & ADDRESS <br />PV-7 <br />PROJECT ID <br />VI <br />C <br />T <br />O <br />R <br /> <br />P <br />E <br />R <br />E <br />Z <br />29 <br />0 <br />6 <br /> S <br />H <br />A <br />L <br />L <br />A <br />D <br />A <br />Y <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br />CA <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />,US <br />A <br />FRESH07/02/2022ORIGINAL PLAN <br />2065 W OBISPO AVE #102 <br />GILBERT, AZ 85233 USA <br />866-572-2637 <br />LIC # CA-1019100 <br />ABHISHEK MAHESH <br />A08/31/2022REV <br />B09/27/2022REV <br />C09/28/2022REV <br />D02/14/2023REV <br />E02/16/2023REV <br />F02/20/2023REV <br />G09/15/2023REV <br />PLACARDS <br />NOTES AND SPECIFICATIONS: <br />·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC <br />2022 ARTICLE, UNLESS SPECIFIC INSTRUCTIONS ARE <br />REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. <br />·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING <br />EFFECTIVE WORDS, COLORS AND SYMBOLS. <br />·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR <br />WIRING METHOD AND SHALL NOT BE HAND WRITTEN. <br />·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE <br />ENVIRONMENT INVOLVED. <br />·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, <br />PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE <br />SPECIFIED. <br />·DO NOT COVER EXISTING MANUFACTURER LABELS. <br />REV <br />SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />ANSI B <br />11" X 17" <br />DATEDESCRIPTION <br />REVISIONS <br />Signature with Seal <br />PROJECT NAME & ADDRESS <br />PV-7 <br />PROJECT ID <br />VI <br />C <br />T <br />O <br />R <br /> <br />P <br />E <br />R <br />E <br />Z <br />29 <br />0 <br />6 <br /> S <br />H <br />A <br />L <br />L <br />A <br />D <br />A <br />Y <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br />CA <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />,US <br />A <br />FRESH07/02/2022ORIGINAL PLAN <br />2065 W OBISPO AVE #102 <br />GILBERT, AZ 85233 USA <br />866-572-2637 <br />LIC # CA-1019100 <br />ABHISHEK MAHESH <br />A08/31/2022REV <br />B09/27/2022REV <br />C09/28/2022REV <br />D02/14/2023REV <br />E02/16/2023REV <br />F02/20/2023REV <br />G09/15/2023REV <br />SOURCES: UTILITY GRID <br />AND PV SOLAR ELECTRIC <br />SYSTEM <br />DUAL POWER SUPPLY <br />LABEL LOCATION: <br />UTILITY SERVICE METER AND MAIN <br />SERVICE PANEL. <br />DO NOT ADD LOADS <br />PHOTOVOLTAIC SYSTEM <br />COMBINER PANEL <br />LABEL LOCATION: <br />PHOTOVOLTAIC AC COMBINER (IF <br />APPLICABLE). <br />WARNING: PHOTOVOLTAIC <br />POWER SOURCE <br />LABEL LOCATION: <br />INTERIOR AND EXTERIOR DC CONDUIT EVERY 1O FT, AT EACH TURN, ABOVE AND <br />BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. <br />ELECTRICAL SHOCK HAZARD <br />IF GROUND FAULT IS INDICATED <br />ALL NORMALLY GROUNDED <br />CONDUCTORS MAY BE <br />UNGROUNDED AND ENERGIZED <br />LABEL LOCATION: <br />INVERTER(S), ENPHASE ENVOY ENCLOSURE <br />(IF APPLICABLE). <br />MAXIMUM AC OPERATING CURRENT: <br />NOMINAL OPERATING AC VOLTAGE: <br /> 27.8 AMPS <br /> 240 VAC <br />PHOTOVOLTAIC AC DISCONNECT <br />LABEL LOCATION: <br />AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF <br />INTERCONNECTION. <br />THE DC CONDUCTORS OF THIS <br />PHOTOVOLTAIC SYSTEM ARE <br />UNGROUNDED AND MAY BE <br />ENERGIZED <br />ELECTRICAL SHOCK HAZARD <br />WARNING! <br />LABEL LOCATION: <br />INVERTER(S), DC DISCONNECTS. <br />ELECTRICAL SHOCK HAZARD <br />DO NOT TOUCH TERMINALS. <br />TERMINALS ON LINE AND LOAD <br />SIDES MAY BE ENERGIZED IN <br />THE OPEN POSITION <br />WARNING! <br />LABEL LOCATION: <br />INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL <br />(IF APPLICABLE). <br />WARNING! <br />WARNING! <br />WARNING! <br />PHOTOVOLTAIC SYSTEM <br />DISCONNECT <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE <br /> "OFF" POSITION TO <br />SHUT DOWN PV SYSTEM <br />AND REDUCE <br />SHOCK HAZARD <br />IN THE ARRAY <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />SOLAR ELECTRIC <br />PV PANELS <br />LABEL LOCATION: <br />AC DISCONNECT, POINT OF INTERCONNECTION <br />LABEL LOCATION: <br />INVERTER(S), DC DISCONNECT(S). <br />INVERTER #1 SOLAREDGE <br />MAXIMUM VOLTAGE <br />MAXIMUM CIRCUIT CURRENT <br />MAX. RATED OUTPUT CURRENT OF <br />THE CHARGE CONTROLLER OR <br />DC-TO-DC- CONVERTER <br />(IF INSTALLED) <br />600VDC <br />15.0ADC <br />15.0ADC <br />PAGE 7 OF 18 <br />POWER SOURCE <br />OUTPUT CONNECTION <br />DO NOT RELOCATE THIS <br />OVERCURRENT DEVICE <br />LABEL LOCATION: <br />ADJACENT TO PV BREAKER (IF <br />APPLICABLE). <br />WARNING! <br />CAUTION: <br />POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE <br />FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN <br />UTILITY METER & MAIN SERVICE PANEL <br />AC DISCONNECT <br />INVERTER <br />(E) UTILITY METER <br />29 <br />0 <br />6 <br /> S <br />H <br />A <br />L <br />L <br />A <br />D <br />A <br />Y <br /> <br />S <br />T <br />(N) INVERTER <br />(N) SECONDARY FUSED <br />AC DISCONNECT-3 <br />(E) MAIN SERVICE PANEL <br />(EXTERIOR) <br />(N) SUB PANEL <br />(INTERIOR) <br />(N) AC DISCONNECT-1(N) PRIMARY FUSED AC <br />DISCONNECT-2 (INTERIOR) <br />(N) TRANSFORMER (INTERIOR) <br />2906 S Halladay St - <br />2018139112/4/2023