Laserfiche WebLink
MSP <br />UM <br />ACD <br />IN <br />V <br />JB <br />3' <br />- <br />5" <br />1 <br />3 <br />' <br />- <br />1 <br />0 <br />" <br />7' <br />- <br />0 <br />" <br />8' <br />- <br />0" <br />8'-7"3" <br />11'-7" <br />4'-5" <br />5'-9" <br />1'-6" <br />GAS <br />SUB <br />REV <br />SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />ANSI B <br />11" X 17" <br />DATE DESCRIPTION <br />REVISIONS <br />Signature with Seal <br />PROJECT NAME & ADDRESS <br />PV-2 <br />PROJECT ID <br />VI <br />C <br />T <br />O <br />R <br /> <br />P <br />E <br />R <br />E <br />Z <br />29 <br />0 <br />6 <br /> <br />S <br /> <br />H <br />A <br />L <br />L <br />A <br />D <br />A <br />Y <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />, <br />U <br />S <br />A <br />FRESH07/02/2022 ORIGINAL PLAN <br />2065 W OBISPO AVE #102 <br />GILBERT, AZ 85233 USA <br />866-572-2637 <br />LIC # CA-1019100 <br />ABHISHEK MAHESH <br />A08/31/2022 REV <br />B09/27/2022 REV <br />C09/28/2022 REV <br />ROOF PLAN & <br />MODULES <br />ROOF DESCRIPTION <br />ROOF TYPE COMP-SHINGLE ROOF <br />ROOF ROOF TILT AZIMUTH RAFTERS <br />SIZE <br />RAFTERS <br />SPACING <br />#1 20°182° 2"x4"24" o.c. <br />#2 20°272° 2"x4"24" o.c. <br />#3 20°92° 2"x4"24" o.c. <br />LEGEND <br />- JUNCTION BOX <br />MSP - MAIN SERVICE PANEL <br />- VENTS, DISH (ROOF OBSTRUCTION) <br />- ROOF ATTACHMENT <br />- RAFTERS <br />- CONDUIT <br />- UTILITY METER <br />SCALE: 1/8" = 1'-0" <br />- SOLAREDGE OPTIMIZER <br />MODULE TYPE, DIMENSIONS & WEIGHT <br />ACD - AC DISCONNECT <br />- INVERTER <br />1 <br />PV-2 <br />NUMBER OF MODULES = 19 MODULES <br />MODULE TYPE = LONGI SOLAR LR4-60HPB 355M 355W MODULES <br />MODULE WEIGHT = 42.99 LBS / 19.5 KG. <br />COMPONENT WEIGHT: 1.5 LBS. PER MODULE <br />TOTAL DEAD LOAD: 845.31 LBS. <br />POINT LOAD PER STANDOFF.: 845.31 LBS / 50 STANDOFF = 16.91 LBS <br />MODULE DIMENSIONS = 69.09"x 40.87" = 19.61 SF <br />UNIT WEIGHT OF ARRAY = 2.27 PSF <br />UM <br />JB <br />INV <br />ARRAY AREA WITH TOTAL ROOF AREA <br />ROOF # OF <br />MODULES <br />ARRAY AREA <br />(Sq. Ft.) <br />TOTAL <br />ROOF <br />AREA <br />(Sq. Ft.) <br />ROOF <br />AREA <br />COVERED <br />BY ARRAY <br />(%) <br />#1 3 58.83 239.00 24.61 <br />#2 11 215.71 488.60 44.15 <br />#3 5 98.05 327.08 29.98 <br />ROOF PLAN & MODULES <br />PAGE 2 OF 17 <br />ARRAY AREA WITH WHOLE ROOF AREA <br />ROOF # OF <br />MODULES <br />ARRAY AREA <br />(Sq. Ft.) <br />TOTAL <br />ROOF <br />AREA <br />(Sq. Ft.) <br />ROOF <br />AREA <br />COVERED <br />BY ARRAY <br />(%) <br />#1-3 19 372.57 1171.41 31.81 <br />LONGI SOLAR <br />LR4-60HPB 355M <br /> 355W MODULES <br />40.87" <br />69 <br />. <br />0 <br />9 <br />" <br />(E <br />) <br /> <br />F <br />R <br />O <br />N <br />T <br /> <br />O <br />F <br />CO <br />M <br />M <br />E <br />R <br />C <br />I <br />A <br />L <br /> <br />B <br />U <br />I <br />L <br />D <br />I <br />N <br />G <br />S <br />H <br />A <br />L <br />L <br />A <br />D <br />A <br />Y <br /> <br />S <br />T <br />(E <br />) <br /> <br />B <br />A <br />C <br />K <br /> <br />O <br />F <br />CO <br />M <br />M <br />E <br />R <br />C <br />I <br />A <br />L <br /> <br />B <br />U <br />I <br />L <br />D <br />I <br />N <br />G <br />ROOF #02 <br />(11) LONGI SOLAR LR4-60HPB <br />355M 355W MODULES <br />ROOF #03 <br />(05) LONGI SOLAR LR4-60HPB <br />355M 355W MODULES <br />ROOF #01 <br />(03) LONGI SOLAR LR4-60HPB <br />355M 355W MODULES <br />ROOF ACCESS POINT <br />(E) MAIN SERVICE PANEL, <br />200A RATED, 240V (EXTERIOR) <br />(E) UTILITY METER <br />(N) AC DISCONNECT <br />(N) SOLAREDGE TECHNOLOGY : <br />SE9KUS INVERTER <br />INTEGRATED RAPID SHUTDOWN <br />3/4" EMT CONDUIT <br />RUN ON ROOF <br />(N) JUNCTION BOX <br />(19) SOLAREDGE POWER <br />OPTIMIZER S-440 <br />(50) CHIKOUSA L FOOT <br />ATTACHMENTS @48"O.C. <br />ROOF #1 <br />TILT - 20° <br />AZIM. - 182° <br />ROOF #2 <br />TILT - 20° <br />AZIM. - 272° <br />ROOF #3 <br />TILT - 20° <br />AZIM. - 92° <br />36 <br />" <br /> <br />F <br />I <br />R <br />E <br /> <br />S <br />E <br />T <br />B <br />A <br />C <br />K <br />36" FIRE SETBACK <br />18" FIRE SETBACK <br />18" FIRE SETBACK <br />1 <br />8" <br />FI <br />RE <br /> <br />SET <br />B <br />AC <br />K <br />1 <br />8" <br />FI <br />RE <br /> <br />SET <br />B <br />AC <br />K <br />18 <br />" FIRE <br /> SE <br />T <br />BAC <br />K <br />18" <br />FIRE <br /> SE <br />T <br />BAC <br />K <br />(N) CHIKO ASPHALT ROOF <br />RACKING SYSTEM <br />(E) GAS METER <br />- GAS METERGAS <br />(N) SUB PANEL, <br />200A RATED, 240V (INTERIOR) <br />- SUB PANELSUB <br />VECTOR PROJECT #: A0035-0204-221 <br />Vector Structural Engineering has reviewed the <br />existing structure with loading from the solar array <br />and lag screw connections to the existing framing. <br />The design of the racking system, connections, and <br />all other structure is by others. Electrical, mechanical, <br />architectural, and all other nonstructural aspects of <br />the design are by others. <br />October 04, 2022 <br />2906 S Halladay St <br />- 101112511 & <br />2017775906/26/23