My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3314 S Lowell St - Plan
PBA
>
Building
>
ProjectDox
>
L
>
Lowell St
>
3314 S Lowell St
>
3314 S Lowell St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2025 4:53:33 PM
Creation date
5/30/2025 8:00:55 AM
Metadata
Fields
Template:
Plan
Permit Number
20176783
20177757
101111215
Full Address
3314 S Lowell St
Document Relationships
101111215 - Permit
(Permit - Plan)
Path:
\Building\Permits\L\Lowell St\3314 S Lowell St
20176783 - Permit
(Permit - Plan)
Path:
\Building\Permits\L\Lowell St\3314 S Lowell St
20177757 - Permit
(Permit - Plan)
Path:
\Building\Permits\L\Lowell St\3314 S Lowell St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
A B C D E F G H <br />A B C D E F G H <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />NE <br />W <br /> <br />P <br />V <br /> <br />S <br />Y <br />S <br />T <br />E <br />M <br />: <br /> <br />3. <br />2 <br />4 <br />0 <br /> k <br />W <br />p <br />DA <br />V <br />E <br /> <br />H <br />A <br />R <br />D <br />Y <br />33 <br />1 <br />4 <br /> <br />S <br />. <br /> <br />L <br />O <br />W <br />E <br />L <br />L <br /> <br />S <br />T <br />. <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />AP <br />N <br />: <br /> <br />4 <br />1 <br />0 <br />2 <br />5 <br />3 <br />1 <br />5 <br />DATE: 06.2.2022 <br />DESIGN BY: V.P. <br />CHECKED BY: <br />REVISIONS <br />R.D. <br />ROBERT DEAN, ILUM SOLAR INC. <br />4135 NORTHGATE BLVD. SUITE 9. <br />SACRAMENTO, CA 95834 <br />PHONE: (916) 905-0941 <br />LIC. No.: 1009260, C-46 <br />E-1 <br />SIGNAGE <br />ELECTRICAL SHOCK HAZARD <br />TERMINALS ON THE LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />WARNING <br />LABEL 1 <br />AT EACH DISCONNECTING MEANS FOR <br />PHOTOVOLTAIC EQUIPMENT (2" X 4"). <br />[CEC 690.13]. <br />POWER SOURCE <br />OUTPUT CONNECTION <br />DO NOT RELOCATE THIS <br />OVERCURRENT DEVICE <br />WARNING <br />LABEL 2 <br />AT POINT OF INTERCONNECTION <br />OVERCURRENT DEVICE (2" X 4"). <br />[CEC 705.12(B)(2)(3)(B)]. <br />PHOTOVOLTAIC SYSTEM <br />AC DISCONNECT <br />RATED AC OUTPUT CURRENT <br />NOMINAL OPERATING AC VOLTAGE <br />LABEL 3 <br />AT POINT OF INTERCONNECTION, MARKED <br />AT DISCONNECTING MEANS (4" X 2"). <br />[CEC 690.54] <br />LABEL 4 <br />AT EACH AC DISCONNECTING MEANS <br />(4" X 1"). <br />[CEC 690.13(B)]. <br />INTERACTIVE PHOTOVOLTAIC SYSTEM CONNECTED <br />PHOTOVOLTAIC SYSTEM DISCONNECT LOCATED <br />SOUTH SIDE OF THE HOUSE <br />DIRECTORY <br />PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE <br />DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING <br />MEANS IF NOT IN THE SAME LOCATION (5 3/4" X 1 1/8"). <br />[CEC 690.56(B)] <br />WHERE THE PV SYSTEMS ARE REMOTELY LOCATED FROM EACH OTHER, A <br />DIRECTORY IN ACCORDANCE WITH 705.10 SHALL BE PROVIDED AT EACH PV <br />SYSTEM DISCONNECTING MEANS. <br />PV SYSTEM EQUIPMENT AND DISCONNECTING MEANS SHALL NOT BE INSTALLED IN <br />BATHROOMS <br />[CEC 690.4(D),(E)] <br />WARNING: PHOTOVOLTAIC <br />POWER SOURCE <br />LABEL 9 <br />AT EXPOSED RACEWAYS, CABLE TRAYS, AND OTHER WIRING <br />METHODS; SPACED AT MAXIMUM 10 FT SECTION OR WHERE <br />SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, <br />OR FLOORS (5 3/4" X 1 1/8"). <br />[CEC 690.31(G)] <br />LETTERS AT LEAST 3/8 INCH; WHITE ON RED BACKGROUND; <br />REFLECTIVE <br />[IFC 605.11.1.1] <br />SOLAR PV SYSTEM <br />EQUIPPED WITH <br />RAPID SHUTDOWN <br />TURN RAPID SHUTDOWN SWITCH TO <br />THE "OFF" POSITION TO SHUT DOWN <br />PV SYSTEM AND REDUCE SHOCK <br />HAZARD IN ARRAY <br />SOLAR ELECTRIC <br />PV PANELS <br />LABEL 6 <br />AT RAPID SHUTDOWN SYSTEM <br />(3 3/4" X 5 1/4"). [CEC 690.56(C)(1)(A)]. <br />WARNING <br />DUAL POWER SUPPLY <br />SOURCES: UTILITY GRID <br />AND PV SOLAR <br />ELECTRIC SYSTEM <br />LABEL 7 <br />AT POINT OF INTERCONNECTION <br />(2 3/4" X 1 5/8"). <br />[CEC 705.12(B)(3)] <br />WARNING <br />SOLAR ELECTRIC <br />CIRCUIT BREAKER <br />IS BACKFED <br />PHOTOVOLTAIC SOLAR <br />AC DISCONNECT <br />LABEL 8 <br />AT POINT OF INTERCONNECTION <br />(2" X 1"). <br />[CEC 705.12(B)(3)] <br />CAUTION <br />SOLAR ELECTRIC SYSTEM CONNECTED <br />LABEL 10 <br />AT UTILITY METER (5 3/4" X 1 1/8") <br />[CEC 690.56(B)] <br />RAPID SHUTDOWN <br />SWITCH FOR <br />SOLAR PV SYSTEM <br />LABEL 5 <br />AT RAPID SHUTDOWN DISCONNECT SWITCH (5 1/4" X 2"). <br />[CEC 690.56(C)(3)]. <br />9 A <br />V240 <br />LABELING NOTES <br />1.1 LABELING REQUIREMENTS BASED ON THE 2019 CALIFORNIA ELECTRICAL CODE, <br />INTERNATIONAL FIRE CODE CHAPTER 12, OSHA STANDARD 1910.145, ANSI Z535 <br />1.2 MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. <br />1.3 LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. <br />1.4 LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8” AND PERMANENTLY AFFIXED. <br />1.5 ALERTING WORDS TO BE COLOR CODED. “DANGER” WILL HAVE RED BACKGROUND; <br />“WARNING” WILL HAVE ORANGE BACKGROUND; “CAUTION” WILL HAVE YELLOW BACKGROUND. <br />[ANSI Z535] <br />3314 S. Lowell St <br />07/29/22
The URL can be used to link to this page
Your browser does not support the video tag.