Laserfiche WebLink
10/21/2021 <br />6. <br />8 <br />0 <br />0 <br />PR <br />A <br />X <br />E <br />D <br />I <br />S <br />, <br /> <br />C <br />A <br />N <br />D <br />I <br />D <br />O <br /> <br />& <br />PR <br />I <br />S <br />C <br />A <br />37 <br />0 <br />2 <br /> <br />A <br />L <br />D <br />E <br />R <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />-- <br />- <br />Eq <br />u <br />i <br />s <br />o <br />l <br />a <br />r <br />1 <br />6 <br />5 <br />3 <br />0 <br /> <br />V <br />e <br />n <br />t <br />u <br />r <br />a <br /> <br />B <br />l <br />v <br />d <br /> <br />S <br />u <br />i <br />t <br />e <br /> <br />1 <br />0 <br />4 <br />En <br />c <br />i <br />n <br />o <br />, <br /> <br />C <br />A <br /> <br />9 <br />1 <br />4 <br />3 <br />6 <br />81 <br />8 <br />. <br />7 <br />8 <br />4 <br />. <br />2 <br />3 <br />0 <br />0 <br />CS <br />L <br />B <br />: <br /> <br />G <br />e <br />n <br />- <br />B <br />; <br /> <br />1 <br />0 <br />0 <br />6 <br />5 <br />3 <br />5 <br />SI <br />G <br />N <br />A <br />T <br />U <br />R <br />E <br />: <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />_ <br />Paper Size <br />Scale <br />Drawn by <br />Title <br />Project Number <br />Sheet <br />1 <br />T-01 <br />SHEET INDEX <br />T-01 TITLE SHEET <br />PV.01 SITE PLAN <br />PV.02 ROOF PLAN <br />PV.03 SINGLE LINE DIAGRAM <br />PV.04 WARNING LABELS & SIGNAGE <br />PV.05 RACKING AND ATTACHMENTS <br />PV.06 PV MODULE DATA SHEET <br />PV.07 INVERTER DATA SHEET <br />PV.08 RAPID SHUTDOWN DATA SHEET <br />PV.09 UL <br />PV.010 GROUNDING <br />GENERAL NOTES: <br />x All electrical equipment shall be labeled, listed, or certified by a Nationally Recognized Testing Laboratory accredited by the United <br />States Occupational Safety Health Administration. <br />x Local Utility provider shall be notified prior to use and activation of any solar photovoltaic installation. <br />x The System will not be interconnected until approval from the local jurisdiction and utility is obtained. <br />x A ladder shall be in place for the inspection in compliance with CAL-OSHA Regulations. <br />x Proper access and working clearance shall be provided as per section 110.26 CEC. <br />x PV equipment, systems, and all associated wiring and interconnections shall only be installed by qualified persons. <br />x All outdoor equipment shall be minimum NEMA 3R rated, including all roof mounted transition boxes and switches. <br />x All exterior conduit, fittings, and boxes shall be rain tight and approved for use in wet locations. <br />x All conductors exposed to weather shall be listed and identified for use in direct sunlight. <br />x The module conductors must be type USE-2 or listed for Photovoltaic (PV) Wire (UL 4703 & 854 Listed). <br />x All conductors must be copper and 90° Rated. <br />x All equipment shall be properly grounded and bonded in accordance with NEC Article 250. <br />x All applicable PV equipment listed and compliant with UL2703 and UL1703. <br />x All NEC required warning signs, markings, and labels shall be posted on equipment and disconnects. <br />x All circuits connected to more than one source shall have over current devices located so as to provide over current protections from <br />all sources. <br />x The PV Power source circuit breaker shall be located at the opposite end of the main service disconnect. <br />x Flexible, fine-stranded cables shall be terminated only with terminals, lugs, devices, or connectors that are identified and listed for such <br />use. <br />x Connectors shall be of latching or locking type. Connectors that are readily accessible and operating over 300 volts shall require a tool <br />to open and shall me marked "Do Not Disconnect under load". <br />x The roof mounted photovoltaic modules, panels, or solar photovoltaic roll roofing material shall have the same or better listed <br />fire-resistance rating than the building roof-covering material. <br />x Smoke alarms and carbon monoxide alarms are required to be retrofitted onto the existing dwelling as per the 2016 CRC. These <br />smoke alarms are required to be in all bedrooms, outside each bedroom, and a least one on each floor of the house. <br />x Smoke alarms and carbon monoxide alarms are to be verified and inspected by the IHE inspector in the field. <br />CONTRACTOR INFORMATION <br />CONTRACTOR Equisolar, Inc <br />ADDRESS <br />16530 Ventura Blvd Suite 104 <br />Encino, CA 91436 <br />PHONE 818.784.2300 <br />CSLB 1006535; Gen-B <br />2 <br />T-01 <br />CLIENT INFORMATION <br />HOMEOWNER PRAXEDIS, CANDIDO & PRISCA <br />ADDRESS <br />3702 ALDER STREET, <br />SANTA ANA, CA 92707 <br />PHONE --- <br />10/22/2021 <br />VSE Project Number: U2880-1484-211 Vector Structural Engineering has reviewed the <br />existing structure with loading from the solar <br />array and screw connections to the existing <br />framing. The design of the racking system, <br />racking connections, and all other structural is <br />by others. Mechanical, architectural, and all <br />other nonstructural aspects of the design are by <br />others. Electrical is by others, unless stamped <br />by Dean Levorsen. <br />Permit #101108485 (Bldg) & 20174689 (Elect) <br />Issued on 11/05/2021 <br />3702 S Alder St <br />11/05/21