Laserfiche WebLink
6" <br /> TY <br />P.Rev <br />PH <br />I <br /> <br />N <br />G <br />U <br />Y <br />E <br />N <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />36 <br />0 <br />6 <br /> <br />S <br /> <br />R <br />O <br />S <br />S <br /> <br />S <br />T <br />. <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />Date Description <br />REVISIONS <br />Signature with Seal <br />Project Name & <br />Address <br />Sheet Size <br />Sheet Number <br />ANSI B <br />11" X 17" <br />PV 2.0 <br />Sheet Name <br />QC BY <br />---- <br />Initial Design 0004/11/2022 <br />SUNERGY, INC. <br />1 GAMELLA STREET, <br />LADERA RANCH CA, 92694 <br />PH. NO.- (562) 544-7394 <br />LICENSE NO.- 1061794 <br />ATTACHMENT <br />DETAIL <br />SCALE: NTS <br />2 ATTACHMENT DETAIL ENLARGED VIEW <br />PV 2.0 <br />SCALE: NTS <br />1 ATTACHMENT DETAIL (SIDE VIEW) <br />PV 2.0 <br />IRONRIDGE XR10 RACKING <br />SYSTEM <br />2"X6" RAFTERS @ 24" O.C <br />5/16"x3" SS LAG BOLT WITH <br />MIN 21 2" THREAD <br />EMBEDMENT, SEALED <br />PENETRATION INTO <br />RAFTERS <br />PV MODULE <br />IRONRIDGE INTEGRATED <br />GROUNDING END CLAMP <br />1/2" OSB SHEATHING <br />IRONRIDGE FLASH FOOT2 <br />ATTACHMENT <br />(E) ASPHALT <br />SHINGLES ROOF <br />GENERAL STRUCTURAL NOTES: <br />1. THE SOLAR PANELS ARE TO BE MOUNTED TO THE <br />ROOF FRAMING USING THE IRONRIDGE RAIL WITH <br />FLASH FOOT-2 ATTACHMENT. THE MOUNTING FEET ARE <br />TO BE SPACED AS SHOWN IN THE DETAILS, AND MUST <br />BE STAGGERED TO ADJACENT FRAMING MEMBERS TO <br />SPREAD OUT THE ADDITIONAL LOAD. <br />2. UNLESS NOTED OTHERWISE, MOUNTING ANCHORS <br />SHALL BE 5/16" LAG SCREWS WITH A MINIMUM OF 2-1/2" <br />PENETRATION INTO ROOF FRAMING. <br />3. THE PROPOSED PV SYSTEM ADDS 2.6 PSF TO THE <br />ROOF FRAMING SYSTEM. <br />4. ROOF LIVE LOAD = 20 PSF TYPICAL, 0 PSF UNDER NEW <br />PV SYSTEM. <br />5. GROUND SNOW LOAD = 35 PSF <br />6. WIND SPEED = 132 MPH <br />7. EXPOSURE CATEGORY = C <br />8. MAX SPACING BETWEEN ATTACHMENTS (INCHES) = 72" <br />SEE (2/PV 2.0) FOR <br />ENLARGED VIEW <br />PV MODULES <br />2"X6" RAFTERS @ 24" O.C <br />(E) ASPHALT <br />SHINGLES ROOF <br />R E G I S T E R E D P R O F E S S I O N A L E N G I N E E R <br />C I V I L <br />No. C70784 <br />Exp. 06/30/2023 <br />S T A T E O F C A L I F O R N I A <br />  <br />3606 S. Ross <br />Street - Solar06/08/22